Published by Dario Pevec *,† , Jurica Babic † and Vedran Podobnik †, Faculty of Electrical Engineering and Computing, University of Zagreb, Zagreb 10000, Croatia;jurica.babic@fer.hr (J.B.); vedran.podobnik@fer.hr (V.P.)* Correspondence: dario.pevec@fer.hr† These authors contributed equally to this work. Abstract: Current trends are showing that the popularity of electric vehicles (EVs) has significantly increased over the lastContinue reading “Electric Vehicles: A Data Science Perspective Review”
Tag Archives: Power Distribution
Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method
Published by Milan ŠIMKO1, Daniel KORENČIAK1, Miroslav GUTTEN1, Richard JANURA1,University of Zilina, Slovakia (1) Abstract. The first part of paper deals with the base information about diagnostics and analysis of transformer insulating system in time domain. The second part of paper deals with proposal measuring system of moisture analysis by return voltage method (RVM) forContinue reading “Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method”
Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents
Published by Rafael ALIPIO, Renan SEGANTINI, Federal Centre of Technological Education of Minas Gerais Abstract. This paper assesses the transient distribution of potentials along a grounding grid subjected to currents representative of first and subsequent strokes. It is shown that the transient non-uniform distribution of potential along the grounding system may lead to the flowContinue reading “Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents”
Influence of Distributed Generation on Sectionalizing Switches Placement in MV Distribution Networks
Published by Wojciech BĄCHOREK1, Mariusz BENESZ1, AGH University of Science and Technology (1) Abstract. This paper presents the influence of distributed generation DG and reclosers placement on the reliability of distribution network. The brute force method and evolutionary algorithm were used to solve the optimization task. The placement of the switches was determined independently usingContinue reading “Influence of Distributed Generation on Sectionalizing Switches Placement in MV Distribution Networks”
The Influence of Power Supply Network Inductance on the HTS Transformer Inrush Current
Published by Grzegorz KOMARZYNIEC1, The Lublin University of Technology, Institute of Electrical Engineering and Electrotechnologies (1) Abstract. The HTS transformer inrush current may lead to thermal damage its windings made of HTS 2G tapes. The parameters affecting the value and duration of the inrush current are: the impedance of the transformer windings and the impedanceContinue reading “The Influence of Power Supply Network Inductance on the HTS Transformer Inrush Current”
The Influence of Distributed Power Sources on Active Power Loss in the Microgrid
Published by Petro D. LEZHNIUK1, Iryna O. HUNKO1, Sergiy V. KRAVCHUK1, Paweł KOMADA2,Konrad GROMASZEK2, Assel MUSSABEKOVA2, Nursanat ASKAROVA3, Abenar ARMAN2Vinnytsia National Technical University, Chair of Electric Stations and Systems (1), Lublin University of Technology, Faculty of Electrical Engineering and Computer Science (2), Kazakh National Research Technical University after K.I. Satpaeva (3) Abstract. One of methodsContinue reading “The Influence of Distributed Power Sources on Active Power Loss in the Microgrid”
Wind Farm and System Modelling Evaluation in Harmonic Propagation Studies
Published by G. A. Mendonça1, H. A. Pereira1,2 and S. R. Silva1,1 Graduate Program in Electrical Engineering – Universidade Federal de Minas Gerais Av. Antônio Carlos 6627, 31270-901, Belo Horizonte, MG, Brazil. Phone: +55-31-3409-4842, e-mail: gforti@gmail.com, heverton.pereira@ufv.com.br, selenios@dee.ufmg.br2 Department of Electrical Engineering, Universidade Federal de Viçosa Av. P.H.Rolfs S/N,36570-000, Viçosa, MG, Brazil Abstract. Wind powerContinue reading “Wind Farm and System Modelling Evaluation in Harmonic Propagation Studies”
Charging Infrastructure and Testing of the Electric Vehicle Energy Battery Decline
Published by Anna ZIELIŃSKA, AGH University of Science and Technology Abstract: The article presents the infrastructure for charging electric vehicles, their development and the types and methods of charging. The paper presents the results of testing the level of vehicle charge depending on the route traveled and its dynamics. The test results show the changeContinue reading “Charging Infrastructure and Testing of the Electric Vehicle Energy Battery Decline”
Prediction of Electricity Production in Island Operation under the different Wind Generation Modes
Published by Dušan MEDVEĎ1, Zsolt ČONKA1 Marek PAVLIK1, Ján ZBOJOVSKY1,Michal KOLCUN1,Michal IVANČÁK1, Technical University of Košice, Department of Electric Power Engineering, Mäsiarska 74, 04001 Košice, Slovakia (1) Abstract. This paper deals with the prediction of electricity generation in particular part of the network (island operation) where were considered various regimes of the wind power plantContinue reading “Prediction of Electricity Production in Island Operation under the different Wind Generation Modes”
Noise and Vibration Analysis of a Distribution Transformer
Published by Dániel MARCSA, eCon Engineering Kft., Hungary Abstract. Transformer noise is a significant contribution to unwanted ambient noise, especially in the vicinity of the electrical transmission facility. It is therefore very important to get to know the mechanism of noise generation of the distribution transformer. As outcomes of this work, a finite element basedContinue reading “Noise and Vibration Analysis of a Distribution Transformer”