Published by Makmur SAINI1, A. M. Shiddiq YUNUS1, Ahmad Rizal SULTAN1, Muh Ruswandi DJALAL1, Mohd. Wasir bin MUSTAFA2, Rahimuddin RAHIMUDDIN3, Ikhlas KITTA3, State Polytechnic of Ujung Pandang (1), University Teknologi Malaysia (2), Hasanuddin University (3) Abstract. This paper introduces a comparative study for fault detection and classification on parallel transmission line using cascade forward andContinue reading “Faults Detection and Classification on Parallel Transmission Lines using Modified Clarke’s Transformation-ANN Approach”
Tag Archives: Power Distribution
Power Flow Forecasts: A Status Quo Review. Part 2: Electricity Demand and Power Flow Prediction
Published by Marcin KOPYT, Warsaw University of Technology, Electrical Power Engineering Institute Abstract. Electricity demand predictions are one of the most important tools used for Power System work planning. However, a departure from traditional solutions seems to be inevitable in the light of ever-increasing RES share. This paper is the second of a two-part extensiveContinue reading “Power Flow Forecasts: A Status Quo Review. Part 2: Electricity Demand and Power Flow Prediction”
Solar Energy and LED Technologies for Street Lighting Demand Side Management SLDSM
Published by Aziz HAFFAF*1, Fatiha LAKDJA1,2, Rachid MEZIANE1, Djaffar OULD ABDESLAM3Electro-Technical Engineering Laboratory, Faculty of Technology, Saida University, Algeria (1) Sidi-Bel-Abbes University, Algeria (2) IRIMAS laboratory, Haute Alsace University, Mulhouse, France (3) Abstract. In this research paper, solar energy and LED technologies as a street lighting demand side management SLDSM option are carried out. TheContinue reading “Solar Energy and LED Technologies for Street Lighting Demand Side Management SLDSM”
An Analysis of Power Supply Reliability Indexes in the Selected Distribution Company
Published by Zbigniew ŁUKASIK, Jacek KOZYRA, Aldona KUŚMIŃSKA-FIJAŁKOWSKA,Uniwersytet Technologiczno-Humanistyczny w Radomiu, Wydział Transportu i Elektrotechniki Abstract. The main goal of this article was to present the problem of discontinuity of energy supply and methods applied by selected distribution company in order to improve power supply reliability indexes. An analysis of discontinuity of supply was basedContinue reading “An Analysis of Power Supply Reliability Indexes in the Selected Distribution Company”
Effect of Soil Moisture on Current-Carrying Capacity of Low-Voltage Power Cables
Published by Stanislaw CZAPP1, Filip RATKOWSKI1, 2, Gdańsk University of Technology (1), Research & Development Center, Eltel Networks Energetyka SA (2) Abstract. One of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for thisContinue reading “Effect of Soil Moisture on Current-Carrying Capacity of Low-Voltage Power Cables”
Voltage Measurements Using Noise Distribution
Published by Grzegorz WĘGRZYN1, Robert SZCZYGIEŁ,AGH2, University of Science and Technology. ORCID: 1. 0000-0002-4132-4939; 2. 0000-0001-6342–0107 Abstract. This paper presents a concept of noised signal voltage measurement using noise distribution. The goal of this project was to work out a new solution for low noise, hybrid pixel detectors that work in single photon counting mode.Continue reading “Voltage Measurements Using Noise Distribution”
Power Quality in the Portuguese Distribution Network
Published by António LEBRE, Fernando BASTIÃO Nuno MELO, Luísa JORGE Pedro VELOSO, António BLANCO, EDP Distribuição – Portugal. Emails: antoniojose.lebrecardoso@edp.pt, nuno.melo@edp.pt, pedro.veloso@edp.pt, fernando.bastiao@edp.pt, luisa.jorge@edp.pt, antonio.blanco@edp.pt ABSTRACT There is an increase in the quantity and in the variety of challenges faced by distribution network operators, concerning to Power Quality (PQ). EDP Distribuição, in Portugal, has beenContinue reading “Power Quality in the Portuguese Distribution Network”
Voltage Fluctuations in Networks with Distributed Power Sources
Published by Maciej MRÓZ1, Zbigniew HANZELKA, Krzysztof CHMIELOWIEC2, TAURON Dystrybucja S.A.(1), AGH – University of Science and Technology (2) Abstract. One of the electromagnetic disturbances generated by distributed power sources, e.g. wind turbines, are voltage fluctuations. An imprecise prediction of the disturbance level may be the reason for erroneous decisions made at the stage ofContinue reading “Voltage Fluctuations in Networks with Distributed Power Sources”
Highest Voltage Sag and Swell Compensation using Single Phase Matrix Converter with Four Controlled Switches
Published by S. Abdul Rahman1, Shumye Birhan Mule2, Estifanos Dagnew Mitiku3, Gebrie Teshome Aduye4, C. Gopinath5, Department of Electrical & Computer Engineering, Institute of Technology, University of Gondar, Ethiopia (1, 2, 3, 4) Department of Electrical & Electronics Engineering, Sri Venkateswara College of Engineering, Chennai, India (5) Abstract: The aim of this paper is toContinue reading “Highest Voltage Sag and Swell Compensation using Single Phase Matrix Converter with Four Controlled Switches”
Nuclear Power Plants Application in Poland – A Way to Meet the Requirements of the Paris Agreement
Published by Iva PAVLOVA-MARCINIAK, Czestochowa University of Technology, Institute of Power Engineering Abstract. The paper presents the analysis of modern nuclear energy development possibilities in Poland, which is considered as an ecological energy source. As the demand for electrical energy is constantly growing the use of such energy sources in one of the ways toContinue reading “Nuclear Power Plants Application in Poland – A Way to Meet the Requirements of the Paris Agreement”