General Reference – Effects of Harmonics at Industrial Facilities

Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Effects of Harmonics at Industrial Facilities, Document ID: PQS0409, Date: September 30, 2004. Abstract: Harmonic currents injected into the system by nonlinear loads, and the voltage distortion they create as they flow through system impedances, can reduce equipment operating reliability and service life. Potential problemsContinue reading “General Reference – Effects of Harmonics at Industrial Facilities”

How High Voltage PTs (VTs) and CTs Limit the Input to PQ Voltage Transient Measuring Instruments and Limit the High Order Harmonic Accuracies of Voltage and Current

Published by Terry Chandler, Director of Engineering, Power Quality Thailand Ltd. & Power Quality Inc., USA. Application Note, Sept. 2013Emails: terryc@powerquality.org, terryc@powerquality.co.th Typical PTs and CTs cause errors and issues in PQ measurements in three areas: 1. Harmonics As the PT and CT have very poor frequency response, they are in affect are a low pass filter onContinue reading “How High Voltage PTs (VTs) and CTs Limit the Input to PQ Voltage Transient Measuring Instruments and Limit the High Order Harmonic Accuracies of Voltage and Current”

General Reference – Modeling for Harmonic Analysis

Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Modeling for Harmonic Analysis, Document ID: PQS0303, Date: January 10, 2003. Abstract: Harmonics have existed on electric power systems for many years. Recently, however, much more attention has been given to monitoring and analyzing the presence and effects of harmonics on utility and customer devicesContinue reading “General Reference – Modeling for Harmonic Analysis”

Harmonic Evaluation at an Industrial Facility

Published by Electrotek Concepts, Inc., PQSoft Case Study: Harmonic Evaluation at an Industrial Facility, Document ID: PQS0502, Date: March 31, 2005. Abstract: A harmonic evaluation was performed at the plastic film manufacturer’s facility. The goals of the evaluation were to develop a solution to mitigate the harmonic voltage distortion caused by the ac and dc adjustableContinue reading “Harmonic Evaluation at an Industrial Facility”

Harmonic Resonance Evaluation for Feeder and Substation Capacitor Banks

Published by Electrotek Concepts, Inc., PQSoft Case Study: Harmonic Resonance Evaluation for Feeder and Substation Capacitor Banks, Document ID: PQS0706, Date: July 27, 2007. Abstract: A utility operates feeder and substation capacitor banks on a 25.56kV distribution feeder. The utility uses frequency scan simulations to determine the effect of distribution feeder and substation capacitor banks onContinue reading “Harmonic Resonance Evaluation for Feeder and Substation Capacitor Banks”

Effect of Distribution Feeder Loading on Harmonic Resonance

Published by Electrotek Concepts, Inc., PQSoft Case Study: Effect of Distribution Feeder Loading on Harmonic Resonance, Document ID: PQS0703, Date: July 26, 2007. Abstract: A utility operates 1200 kVAr and 600 kVAr capacitor banks on a 25.56kV distribution feeder. The utility uses frequency scan simulations to determine the effect of the capacitor banks and seasonal loadContinue reading “Effect of Distribution Feeder Loading on Harmonic Resonance”

Distribution System Harmonic Evaluation

Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution System Harmonic Evaluation, Document ID: PQS1013, Date: October 15, 2010. Abstract: This case study presents a utility distribution system harmonic analysis evaluation. The simulations were completed using the SuperHarm program. The analysis included frequency response and harmonic distortion simulations for a 13.2 kV substation and several industrialContinue reading “Distribution System Harmonic Evaluation”

Electrical Vehicle Impact on Distribution Network Power Quality

Published by Sampsa KUPARI, Metropolia, Helsinki University of Applied Sciences Abstract: The electrical vehicle form a huge load (and occasionally a generator as well) that is not resistive but possibly of nonlinear character. This may have an effect on distribution network power quality and possibly disturb seriously other consumers. If this is not taken careContinue reading “Electrical Vehicle Impact on Distribution Network Power Quality”

Distribution Substation Harmonic Measurement Data Evaluation

Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Substation Harmonic Measurement Data Evaluation, Document ID: PQS1016, Date: October 15, 2010. Abstract: This case study presents a distribution harmonic data analysis for a substation monitoring location for a three-month period. The utility substation included a step-down transformer and a number of distribution feeders that supplied aContinue reading “Distribution Substation Harmonic Measurement Data Evaluation”

Harmonics Generation, Propagation and Purging Techniques in Non-Linear Loads

Published by Hadeed Ahmed Sher, Khaled E. Addoweesh and Yasin Khan 1. Introduction Industrial revolution has transformed the whole life with advanced technological improvements. The major contribution in the industrial revolution is due to the availability of electrical power that is distributed through electrical utilities around the world. The concept of power quality in thisContinue reading “Harmonics Generation, Propagation and Purging Techniques in Non-Linear Loads”