Published by Jonny Carlsson, Unipower AB, Case Study: Container Harbour in Gothenburg, Date: November 8th, 2010. http://www.unipower.se The most important problem was the sags that were caused by the container cranes. The cranes created a lot of high reactive power during the start of the lift procedure. The high currents caused high demand on the transformerContinue reading “Container Harbour in Gothenburg”
Tag Archives: Case Studies
Measuring PQ Issues in a Bus Depot Using Unipower HW and Software
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Introduction This case study explores how advanced power quality measurement technology facilitated the diagnosis of severe power quality disturbances in a bus depot. These disturbances, which neither the bus operator nor the bus manufacturer initially attributed to electrical quality issues, were ultimately traced toContinue reading “Measuring PQ Issues in a Bus Depot Using Unipower HW and Software”
Upstream Frequency Disturbance
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se We have received questions about disturbances in the grid. Do we have any examples? Here is an interesting example showing how disturbances spread through the network. A major frequency disturbance occured in Scandinavia on December 1, 2005. In this comparison we have compared measuring dataContinue reading “Upstream Frequency Disturbance”
Evaluating Direction of Harmonics – Power Harmonics
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se One important issue is how to trace the source of harmonics. The example below shows harmonic filters connected until 11.00 and there is no voltage distortion as expected. After 11.00 the filters were disconnected due to a fault and voltage harmonics can be seen.Continue reading “Evaluating Direction of Harmonics – Power Harmonics”
Bridges to Nowhere: Poor Power Quality Prevents Growth
Published by Civian Kiki Massa and Jay Taneja STIMA Lab, University of Massachusetts, Amherst, USA July 2023 Summary: Access to electricity continues to expand worldwide, but even where people are connected to the power grid, they often face challenges including frequent power outages and, less visibly, intermittent periods where electricity is available but only withContinue reading “Bridges to Nowhere: Poor Power Quality Prevents Growth”
Faults and Defects in Power Transformers – A Case Study
Published by Cacilda de Jesus Ribeiro1; André Pereira Marques2,3; Cláudio Henrique Bezerra Azevedo2; Denise Cascão PoliSouza1; Bernardo Pinheiro Alvarenga1; Reinaldo Gonçalves Nogueira1 1School of Electrical and Computer Engineering, Federal University of Goiás, Goiânia, GO, Brazil,2CELG Distribuição, Goiânia, GO, Brazil,3Federal Institute of Education, Science and Technology of Goiás, Goiânia, GO, Brazil Abstract – Power transformers playContinue reading “Faults and Defects in Power Transformers – A Case Study”
IEEE 519-1992 Compliance
Published by Electrotek Concepts, Inc., PQSoft Case Study: IEEE 519 Compliance, Document ID: PQS0321, Date: October 10, 2003. Abstract: IEEE Standard 519-1992 is a standard that addresses the need for limiting the harmonic current a customer injects onto the utility system. It also protects the customer by specifying maximum harmonic voltage distortion levels that utilities canContinue reading “IEEE 519-1992 Compliance”
Harmonic Measurement Data Evaluation
Published by Electrotek Concepts, Inc., PQSoft Case Study: Harmonic Measurement Data Evaluation, Document ID: PQS1001, Date: March 15, 2010. Abstract: Utility power system harmonic problems can often be solved using a comprehensive approach including site surveys, harmonic measurements, and computer simulations. This case study presents a harmonic data analysis for a utility 12.47kV substation monitoring locationContinue reading “Harmonic Measurement Data Evaluation”
General Reference – Modeling for Harmonic Analysis
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Modeling for Harmonic Analysis, Document ID: PQS0303, Date: January 10, 2003. Abstract: Harmonics have existed on electric power systems for many years. Recently, however, much more attention has been given to monitoring and analyzing the presence and effects of harmonics on utility and customer devicesContinue reading “General Reference – Modeling for Harmonic Analysis”
A Methodological Proposal for Monitoring, Analyzing and Estimating Power Quality Indices: the case of Bogotá-Colombia
Published by L. E. Gallego, Student Member IEEE, H. Torres, Member IEEE, F.A. Pavas, Student Member IEEE, D.F. Urrutia, Student Member IEEE, G. A. Cajamarca, and D. Rondón, Student Member IEEE. Abstract—The Estimation of Power Quality (PQ) indices has a vital importance on the development of national PQ standards not only because provides truthful informationContinue reading “A Methodological Proposal for Monitoring, Analyzing and Estimating Power Quality Indices: the case of Bogotá-Colombia”