Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation

Published by 1. Nuri Berisha, 2. Bahri Prebreza*, 3. Petrit Emini, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0001-8615-637X; 2. 0000-0003-1950-026X; 3. 0000-0002-2833-9001 Abstract. Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells,Continue reading “Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation”

Analysis of Annual Load Variability in the Polish Electric Power System

Published by Kornelia BANASIK1, Andrzej Ł. CHOJNACKI2, Agata KAŹMIERCZYK3, Kielce University of Technology, Faculty of Electrical Engineering, Automatic Control and Computer Science, Department of Power Engineering, Power Electronics and Electrical MachinesORCID: 1. 0000-0002-6629-8650; 2.0000-0002-9227-7538; 3. 0000-0002-4247-4904 Abstract: The paper presents an analysis of the annual variability of power system loads in Poland over a periodContinue reading “Analysis of Annual Load Variability in the Polish Electric Power System”

Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters

Published by 1. Aleksander CHUDY, 2. Paweł A. MAZUREK, Lublin University of Technology ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. The research focused on one–week long measurement of power quality parameters at the connection point of a 450 kW charging station (pantograph type) in the distribution substation. The bus terminal was equipped with 1200 kVA 15.75/0.42Continue reading “Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters”

Analysis of Seasonality and Causes of Equipment and Facility Failures in Electric Power Distribution Networks

Published by Andrzej Ł. CHOJNACKI, Kielce University of Technology, Department of Power Engineering ORCID: 0000-0002-9227-7538 Abstract. The article presents the results of analyses concerning the seasonality and causes of damage to equipment and facilities operated in 110kV, MV and LV power distribution networks. These facilities include 110kV overhead lines, 110kV/SN substations, MV overhead and cableContinue reading “Analysis of Seasonality and Causes of Equipment and Facility Failures in Electric Power Distribution Networks”

UPS Problem at Datacentre

Published by Unipower AB, Case Study: UPS Problem at Datacentre, Date: January 29th, 2017. Email: info@unipower.se Summary A software development company builds a new datacentre and experience problems with the UPS units and a hard drive failure. A monitoring system, PQ Secure from Unipower AB, was installed and it could be determined that the UPS units,Continue reading “UPS Problem at Datacentre”

Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load

Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, Salam Ibrahim khather3, University of Mosul (1), Ninevah University (2,3) ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245, 3. 0000-0002-9082-2360 Abstract. The standalone solar photovoltaic system (SA-SPV) is an appealing alternative for carrying out the electrification process in rural regions through packages in lots of countries. The photovoltaic systems areContinue reading “Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load”

Example of Frequency Variations causing SlowScan Recording

Published by Jonny Carlsson, Unipower AB, Case Study: Example of Frequency Variations causing SlowScan Recording, Date: October 25th, 2011. http://www.unipower.se In the following examples a Unipower UP2210 Power Quality meter is measuring SlowScan events. The SlowScan trig level is set to 50Hz +- 0.15Hz with a recorder time of 120 seconds. Example 1:The voltage level isContinue reading “Example of Frequency Variations causing SlowScan Recording”

Container Harbour in Gothenburg

Published by Jonny Carlsson, Unipower AB, Case Study: Container Harbour in Gothenburg, Date: November 8th, 2010. http://www.unipower.se The most important problem was the sags that were caused by the container cranes. The cranes created a lot of high reactive power during the start of the lift procedure. The high currents caused high demand on the transformerContinue reading “Container Harbour in Gothenburg”

Harmonic Information Management System

Published by 1. Johan ADOLFSSON, Director, Unipower AB, ja@unipower.se, 2. Peter ANDERSSON, CEO, Unipower AB, psa@unipower.se, 3. Nilesh CHINTALWAR, GM, PCI Ltd, nilesh@prime-pci.in, 4. Shital SHAH, PCI Ltd, shitalshah@prime-pci.in INTRODUCTION In the vast majority of countries today there are regulations and standards implemented that specify the maximum level of harmonic content. Some countries implement theContinue reading “Harmonic Information Management System”

Measuring PQ Issues in a Bus Depot Using Unipower HW and Software

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Introduction This case study explores how advanced power quality measurement technology facilitated the diagnosis of severe power quality disturbances in a bus depot. These disturbances, which neither the bus operator nor the bus manufacturer initially attributed to electrical quality issues, were ultimately traced toContinue reading “Measuring PQ Issues in a Bus Depot Using Unipower HW and Software”