The Solar Photovoltaic Energy Capacity for a Parking Project at USTO University

Published by Nessim Abderrahim BOURAHLA1, Mustapha BENGHANEM2, Hamid BOUZEBOUDJA2, Abed BOUADI2, Ali TAHRI2, Higher school of electrical and energy engineering of ran,’’ESGEE’’,Oran, Algeria (1), University of Science and Technology of Oran,’’USTO-MB’’, Oran, Algeria (2)ORCID: 1. 0009-0001-1479-1355 Abstract. A notable shift towards incorporating decentralized energy resources into electrical grids is currently in progress. This article conductsContinue reading “The Solar Photovoltaic Energy Capacity for a Parking Project at USTO University”

Distance Protection Operation During Earth-Faults in High Voltage Networks with Cable Inserts

Published by 1. Dominik DUDA, 2. Krzysztof MAŹNIEWSKI, 3. Bernard WITEK, Silesian University of Technology, Faculty of Electrical Engineering, Department of Power System and ControlORCID: 1. 0000-0003-3247-2814; 2. 0000-0003-4357-6432, 3. 0000-0001-6732-9298 Abstract. Selected problems occurring in distance protection systems during earth faults in high voltage overhead cable lines (HV) were analyzed. The Alternative Transients ProgramContinue reading “Distance Protection Operation During Earth-Faults in High Voltage Networks with Cable Inserts”

Identification of Electric Field Strength in Aircrafts

Published by 1. Joanna MICHAŁOWSKA1, 2. Paweł TOMIŁO2, 3. Jarosław PYTKA2, 4. Łukasz PUZIO1, 5. Arkadiusz TOFIL1, The University College of Applied Science in Chelm (1), Lublin University of Technology (2) ORCID: 1.0000-0002-2353-6305, 2. 0000-0003-4461-3194, 3. 0000-0002-5474-3585, 4. 0000-0002-7116-8586, 5. 0000-0003-2392-6597 Abstract. The development of new technologies contributes to an increase in the value ofContinue reading “Identification of Electric Field Strength in Aircrafts”

A New Approach to Cross-Bonding in Medium Voltage Cable Lines

Published by Jacek KLUCZNIK, Gdansk University of Technology, Faculty of Electrical and Control Engineering. ORCID: 0000-0002-2328-9180 Abstract. The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused byContinue reading “A New Approach to Cross-Bonding in Medium Voltage Cable Lines”

Power System Small Signal Stability Enhancement Using Fuzzy Based STATCOM

Published by Habitamu Endalamaew KASSAHUN1, Ayodeji Olalekan SALAU2,4, Oluwafunso Oluwole OSALONI2, Olawale Joshua OLALUYI3, Department of Electrical and Computer Engineering, University of Gondar, Gondar, Ethiopia (1), Department of Electrical/Electronics and Computer Engineering, Afe Babalola University, Ado-Ekiti, Nigeria (2), Department of Electrical and Electronics Engineering, Bamidele Olumilua University of Science, Education, and Technology, Ikere-Ekiti, Nigeria (3),Continue reading “Power System Small Signal Stability Enhancement Using Fuzzy Based STATCOM”

Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis

Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2,Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The article is the second part of the analysis of the impact of connecting PV sources to the low voltage distribution network on the riskContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis”

Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State

Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2, Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The paper presents selected issues related with MV/LV transformer stations to which local energy sources – photovoltaic power plants are connected. General parameters ofContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State”

Analysing the Performance of H5 Inverters in a Photovoltaic System

Published by 1. Mohd Sanusi Bin Mohd Mokhtar1, 2. Mohd Shafie Bin Bakar2, 3. Mohd Shawal Bin Jadin2, Paya Besar Community College (1), Faculty of Electrical and Electronics Engineering Technology, Universiti Malaysia Pahang (UMP) (2) ORCID: 2. 0000-0003-2905-6449; 3.0000-0001-6253-7821 Abstract. In this paper, a simulation study on H5 topology is presented. H5 topology is aContinue reading “Analysing the Performance of H5 Inverters in a Photovoltaic System”

Electricity Transportation using HVDC Technology for Algerian Southern Sun Power Plants

Published by 1. Mohammed SAAIDIA, 2. Abdelghani GUECHI, 3. Nedjem-Eddine BENCHOUIA, University Mohamed-Cherif Messaadia of Souk-Ahras . ORCID: 1. 0000-0002-7778-8591; 3. 0000-0002-4761-940 Abstract. Algeria is worldly known as one of the big producers and exporters of fossil fuels. However, by developing an adequate energy policy, it could become one of the great sun power (SP)Continue reading “Electricity Transportation using HVDC Technology for Algerian Southern Sun Power Plants”

Determination of the Place and Degree of Damage Insulation in Cables

Published by Nahid MUFIDZADA1, Gulgaz İSMAYILOVA2, Azerbaijan State Oil and Industry University, Power Faculty, “Electroenergetics” department, Baku, AzerbaijanORCID: 0000-0003-4063-2128, 0000-0003-0063-2020 Abstract. A new method has been developed to determine the location and degree of insulation damage in cables. An electrical circuit is defined, using which this task is performed. According to this scheme, one endContinue reading “Determination of the Place and Degree of Damage Insulation in Cables”