Published by Tural Aliyev1, Aydin Aliyev2,Azerbaijan State Oil and İndustry University, Baku, Azerbaijan ORCID: 1. 0000-0003-0751-3952, 2. 0000-0002-1631-0543 Abstract. This article aims to shed light on the critical aspects of power transformer assessment and proposes avenues for improvement in current methodologies, emphasizing the need for a more comprehensive and integrated approach to ensure the reliabilityContinue reading “Modern Methods Of Evaluating the Technical Condition of Power Transformers”
Tag Archives: Transformers
Problems of Designing Electric Vehicle Charging Stations
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and TechnologyORCID: 0000-0002-1628-1818; Abstract. The article presents the issues of designing electric vehicle charging stations. The general requirements that a vehicle charging station should meet are presented. The article focuses on the electric part of the vehicle charging station. Attention was also focused on the safety rulesContinue reading “Problems of Designing Electric Vehicle Charging Stations”
Renewable Energy Collector Transformers
Published by 1. Waldemar ZIOMEK, 2. Krishnamurthy VIJAYAN, PTI Transformers LP, Winnipeg, MB, Canada ORCID: 1. 0000-0002-1216-6513 Abstract. The renewable energy collector transformer (RCT) in a solar station, or a wind farm, transforms the voltage from the collector system to the transmission level voltages. As the primary goal is stepping up the voltage, the RCTContinue reading “Renewable Energy Collector Transformers”
Protection of DC Microgrid using ΔCB
Published by 1. Marwan R. Abed, 2. Oday A. Ahmed, 3. Ghassan A. Bilal, University of Technology Iraq, Baghdad, ORCID: 1. 0000-0002-1257-2810; 2. 0000-0001-7214-3412; 3. 0000-0002-5090-103X Abstract. When implementing a DC distribution network, it is much easier to integrate distributed energy sources than it is with an ac grid. Furthermore, the efficiency and reliability ofContinue reading “Protection of DC Microgrid using ΔCB”
Localizing Faults in Power Transmission Line with Applying Signals of Directional Elements at Both Line Ends
Published by 1. Justyna HERLENDER, 2. Jan IŻYKOWSKI, Wroclaw University of Science and Technology, Faculty of Electrical Engineering, Department of Electrical Power Engineering Professor emeritus. ORCID 1. 0000-0002-9469-4546; 2. 0000-0002-1048-551 Abstract. This paper presents the algorithm intended for localizing faults in a power transmission line for an inspection-repair purpose. Its innovative element is that aContinue reading “Localizing Faults in Power Transmission Line with Applying Signals of Directional Elements at Both Line Ends”
Selected Voltage Control Methods in LV Local Distribution Grids with High Penetration of PV
Published by Paweł SZCZEŚNIAK1, Piotr POWROŹNIK2, Elżbieta SZTAJMEC3, University of Zielona Góra, Institute of Automatic Control, Electronics and Electrical Engineering (1), University of Zielona Góra, Institute of Metrology, Electronics and Computer Science (2), Rzeszow University of Technology, Departament of Power Electronics and Power Engineering (3)ORCID: 1.0000-0002-5822-3878; 2.0000-0001-7485-9959; 3.0000-0002-2125-0207 Abstract. The growth in new prosumer electricityContinue reading “Selected Voltage Control Methods in LV Local Distribution Grids with High Penetration of PV”
High impedance Fault Detection in Low Voltage Overhead Distribution based Wavelet and Harmonic Indices
Published by Enaam ALBANNA1, Alya H. AL-RIFAIE2, Ahmed A. Abdullah AL-KARAKCHI3, Northern Technical University (1,2,3) ORCID: 1. 0000-0002-3974-0116; 2. 0000-0002-7978-2193; 3. 0000-0003-1151-3015; Abstract. High-impedance fault HIF occurs when an energized conductor makes contact with a surface with a high impedance. Conventional overcurrent protection cannot detect this fault due to the low fault current, and thereContinue reading “High impedance Fault Detection in Low Voltage Overhead Distribution based Wavelet and Harmonic Indices”
Analysis of Switching Overvoltages and Protection from Atmospheric Overvoltages for 400kV Switchgears in the Kosovo Power System using ATP/EMTP
Published by 1. Bahri PREBREZA, 2. Nuri BERISHA1*, 3. Bashkim STATOVCI, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0003-1950-026X; 2. 0000-0001-8615-637X; 3. 0000-0002-6840-0778 Abstract. Power systems might experience electrical problems or power outages, due to atmospheric discharges. The quality of the protection from atmospheric overvoltages will increase the life of the equipmentContinue reading “Analysis of Switching Overvoltages and Protection from Atmospheric Overvoltages for 400kV Switchgears in the Kosovo Power System using ATP/EMTP”
Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis
Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2,Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The article is the second part of the analysis of the impact of connecting PV sources to the low voltage distribution network on the riskContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis”
Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State
Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2, Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The paper presents selected issues related with MV/LV transformer stations to which local energy sources – photovoltaic power plants are connected. General parameters ofContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State”