Customer Induction Motor Starting Evaluation

Published by Electrotek Concepts, Inc., PQSoft Case Study: Customer Induction Motor Starting Evaluation, Document ID: PQS0904, Date: October 15, 2009. Abstract: This case study shows the results for simulations completed to determine the severity of an undervoltage condition during starting of a customer induction motor starting. The simulations for the case were completed using the PSCADContinue reading “Customer Induction Motor Starting Evaluation”

Power Factor Correction

Published by Electrotek Concepts, Inc., PQSoft Case Study: Power Factor Correction, Document ID: PQS0312, Date: April 16, 2003. Abstract: Low power factor because it means that you are using the facility’s electrical system inefficiently. It can also cause equipment overloads, low voltage conditions, and greater line losses. Most importantly, low power factor can increase totalContinue reading “Power Factor Correction”

Voltage Notching and Distribution Systems – Large Induction Motor Drive

Published by Electrotek Concepts, Inc., PQSoft Case Study: Voltage Notching and Distribution Systems – Large Induction Motor Drive, Document ID: PQS0320, Date: July 18, 2003. Abstract: This case describes voltage notching associated with large adjustable speed drives. The notching is a normal characteristic of a phase-controlled rectifier but this paper illustrates problems that can occur onContinue reading “Voltage Notching and Distribution Systems – Large Induction Motor Drive”

Real Time Sustainable Power Quality Analysis of Non-Linear Load under Symmetrical Conditions

Published by Pavan Babu Bandla 1, Indragandhi Vairavasundaram 1, Yuvaraja Teekaraman 2, Ramya Kuppusamy 3 and Srete Nikolovski 4,* 1School of Electrical Engineering, Vellore Institute of Technology, Vellore 632014, India2MOBI-Mobility, Logistics and Automotive Technology Research Centre, Vrije Universiteit Brussel, 1050 Brussels, Belgium3Department of Electrical and Electronics Engineering, Sri Sairam College of Engineering, Bangalore 562106, India4PowerContinue reading “Real Time Sustainable Power Quality Analysis of Non-Linear Load under Symmetrical Conditions”

Harmonics & Waveform Measurements Low Pass Filter & Sine Wave Filter for a 460V 100HP AC Motor with VFD

Published by Dranetz™ Technologies, Inc., Case Study, Website: dranetz.com. This case study was submitted by Ing. Leopoldo Martínez Basulto, Dranetz México. INTRODUCTION Harmonics are an important PQ issue today. Variable Frequency Drives (VFD), Uninterruptible Power Systems (UPS), computers, LED lighting, electronic ballasts, etc. are widely used in all kinds of facilities. It is well knownContinue reading “Harmonics & Waveform Measurements Low Pass Filter & Sine Wave Filter for a 460V 100HP AC Motor with VFD”

Beware of Asymmetry – Causes, Consequences, Measurement and Control

Published by Sonel Three-phase motors are overheating! Overcurrent breakers are triggering without a reason! Energy bills are higher than expected! Undesirable Asymmetry The economic benefits of energy suppliers and their users are strongly dependent on reliability, safety and efficiency of the power system. One of the phenomena that is strongly related to the efficiency ofContinue reading “Beware of Asymmetry – Causes, Consequences, Measurement and Control”

Fluke 43B PQ Analyzer – Motor Loads

Applications Guide, April 2001 Published by Fluke Corporation Introduction This section provides examples that you can use to troubleshoot induction motors with and without an adjustable speed drive. Figure 4. Distribution System: Motor Loads Induction Motors Checking Voltage Imbalance For 3 phase induction motors, the supply voltage on all three phases should be in balance.Continue reading “Fluke 43B PQ Analyzer – Motor Loads”

Power Quality, Electronic Motor Drives, & Other Sensitive Loads

Published by Power Quality (Thailand) Co., Ltd. http://www.powerquality.co.th Classes of Sensitive Loads Electronic motor drives Computers Computerized equipment Automated machines that have PLC’s Automatic test equipment Electronic scales Electronic Motor Drives Types of drives Basic electrical operations Understanding electric motors DC drives AC drives Harmonics and power factor Future What is an Electronic Drive? TheContinue reading “Power Quality, Electronic Motor Drives, & Other Sensitive Loads”

Stalled Motors

Published by Dranetz – BMI Case Studies In this case study, we look at an industrial customer with two 1250hp motors on a 4kV circuit, whose motors would not start. To determine the problem, we installed a Dranetz – BMI PP4300 at the motor input. The power monitoring instrument quickly identified the motor itself asContinue reading “Stalled Motors”