Power Flow Control Algorithm in a Microgrid with Energy Storage

Published by 1.Dominika KACZOROWSKA, 2.Przemysław JANIK, 3.Łukasz JASIŃSKI, 4.Jacek REZMER, 5.Vishnu SURESH, Wroclaw University of Science and TechnologyORCID: 1. 0000-0002-2312-2903; 2. 0000-0001-5300-7845; 3. 0000-0002-7484-9424; 4. 0000-0002-2822-7595; 5. 0000-0003-2891-9206 Abstract. This paper discusses power flow control algorithm in a microgrid with battery energy storage system. Depending on the state of charge of the storage and theContinue reading “Power Flow Control Algorithm in a Microgrid with Energy Storage”

Load Flow Analysis in Local Microgrid with Storage

Published by Vishnu SURESH, Dominika KACZOROWSKA, Przemyslaw JANIK, Jacek REZMER, Wroclaw University of Science and Technology Abstract. This paper deals with load flow analysis of local microgrid containing a stochastic renewable energy source and storage. The study is carried out using the Matpower toolbox with all relevant constraints considered regarding storage, power lines and otherContinue reading “Load Flow Analysis in Local Microgrid with Storage”

The Influence of Distributed Power Sources on Active Power Loss in the Microgrid

Published by Petro D. LEZHNIUK1, Iryna O. HUNKO1, Sergiy V. KRAVCHUK1, Paweł KOMADA2,Konrad GROMASZEK2, Assel MUSSABEKOVA2, Nursanat ASKAROVA3, Abenar ARMAN2Vinnytsia National Technical University, Chair of Electric Stations and Systems (1), Lublin University of Technology, Faculty of Electrical Engineering and Computer Science (2), Kazakh National Research Technical University after K.I. Satpaeva (3) Abstract. One of methodsContinue reading “The Influence of Distributed Power Sources on Active Power Loss in the Microgrid”

Designing a Passive Filter for Reducing Harmonic Distortion in the Hybrid Micro-grid Including Wind Turbine, Solar Cell and Nonlinear Load

Published by Ali BAGHERI, Mohsen ALIZADEH, Department of Electrical Engineering, Yadegar -e- Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran Abstract. One of the most important indices of power quality in distribution grids is the harmonic distortion, which can affect the reliability of the micro-grid. On the other hand, the growth ofContinue reading “Designing a Passive Filter for Reducing Harmonic Distortion in the Hybrid Micro-grid Including Wind Turbine, Solar Cell and Nonlinear Load”

Applications of Grid-connected Battery Energy Storage Systems

Published by Rakesh Kumar, EE Power – Technical Articles: Applications of Grid-connected Battery Energy Storage Systems, February 17, 2023. Grid operators, distributed generator plant owners, energy retailers, and consumers may receive various services from grid-connected battery energy storage systems. Learn more about the applications here. Battery energy storage systems (BESSes) act as reserve energy that canContinue reading “Applications of Grid-connected Battery Energy Storage Systems”

IM Drive System Supplied from PV Panels with Energy Storage – Experimental Setup

Published by Wojciech MATELSKI1, Electrotechnical Institute, Warsaw Abstract. The article describes a practical implementation of the induction motor (IM) drive system powered from photovoltaic (PV) panels. The system incorporates an energy storage device, in form of a supercapacitor bank, and enables an AC grid connection. Two system concepts are considered, thus a discussion about theContinue reading “IM Drive System Supplied from PV Panels with Energy Storage – Experimental Setup”

Case Studies on Ground-Fault Protection of Microgrid Power Systems with Diverse Power Sources

Published by Dirk Danninger IEEE Member Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163, USAScott Manson Senior Member, IEEE Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163, USAFernando Calero IEEE Member Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163, USACeeman Vellaithurai Senior Member, IEEE Schweitzer EngineeringContinue reading “Case Studies on Ground-Fault Protection of Microgrid Power Systems with Diverse Power Sources”

An Introduction to Microgrid Energy Management Systems

Published by Anushree Ramanath, EE Power – Technical Articles: An Introduction to Microgrid Energy Management Systems, July 05, 2021. This article highlights the growth of microgrids and the components of these systems. With the growing number of industries and businesses, access to reliable and cost-effective power is critical. This leads to demand for small-scale powerContinue reading “An Introduction to Microgrid Energy Management Systems”

Microgrid Operations and Applications

Published by Anushree Ramanath, EE Power – Technical Articles: Microgrid Operations and Applications, August 01, 2021. In this article, we’ll learn about microgrids, their operations, and applications in electrical utilities and various organizations. Today’s world relies on an uninterrupted electricity supply. A microgrid is a local energy grid with the capability of controlling its components [1].Continue reading “Microgrid Operations and Applications”

New Idea in Power Networks Development. Selected Problems

Published by Bożena MATUSIAK, Anna PAMUŁA, Jerzy S. ZIELIŃSKI, Katedra Informatyki Uniwersytetu Łódzkiego Abstract. Smart grids and thereafter open grids development implies changes in organizations, technical equipment Power Networks (especially ICT). These new grids influence also on organization and operation of the energy markets, for which it is very important to know correct forecast (mostlyContinue reading “New Idea in Power Networks Development. Selected Problems”