Published by Liu Liqun, Liu Chunxia*, Taiyuan University of Science & Technology Abstract. At present, an optimal maximum power tracking (MPPT) and grid-connected control methods for a PV power system are very important to improve the output efficiency. However, most of literatures only introduce the MPPT or PLL method, respectively. A novel MPPT method isContinue reading “A Grid-Connected PV Power System Total Considers the MPPT and SSRF-SPLL Control Technologies”
Tag Archives: Microgrid
Power Quality Analysis of Grid-Connected Photovoltaic Systems in Distribution Networks
Published by Masoud FARHOODNEA1, Azah MOHAMED1, Hussain SHAREEF1, Hadi ZAYANDEHROODI1, University Kebangsaan Malaysia (UKM) (1) Abstract. This paper presents a dynamic PQ analysis on the effects of high-penetrated grid-connected photovoltaic (PV) systems in a distribution system under different weather conditions. To track practical considerations, all information on PV units and weather conditions given in thisContinue reading “Power Quality Analysis of Grid-Connected Photovoltaic Systems in Distribution Networks”
Research on Design and Control of Microgrid System
Published by Yanbo CHE, Jian CHEN,School of Electrical Engineering & Automation, Tianjin University, Tianjin China. Abstract. Microgrid system has received more and more attention internationally in recent years. As the most effective form of distributed generations, microgrid system has also found wide applications in many areas. In this paper, the optimal configuration issue of microgridContinue reading “Research on Design and Control of Microgrid System”
Renewable Energy Sources Intrusion into Smart Grids – Selected Problems
Published by Bożena E. MATUSIAK, Jerzy S. ZIELIŃSKI, University of Lodz Abstract. The aim of the paper are selected problems resulting from Renewable Energy Sources (RES) intrusion into Smart Grids (SG) presentation. Upon considerations there are: wind turbines influence on power system operation, RES and microgrids operation with a Power System, new Energy Market forContinue reading “Renewable Energy Sources Intrusion into Smart Grids – Selected Problems”
A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications
Published by Yang HAN1, Lin XU2University of Electronic Science and Technology of China (1), Shanghai Jiao Tong University (2) Abstract. This paper presents the survey of the smart grid technologies, including the background, motivation and practical applications. The driving forces for the smart grid technologies are presented, including the blackout, global energy crisis and environmentalContinue reading “A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications”
Wind Turbine Operation in Power Systems & Grid Connection Requirements
Published by K. B. Mohd. Umar Ansari1, Manjeet Singh2, Sandeep Kumar3 B.E (EEE), M.Tech (Electrical Power & Energy Systems), Ex- Engineer – GET, Tata Motors Pvt. Ltd., Sector 11,Udham Singh Nagar, Pantnagar, UK, India. 1B.Tech (EN), Ex-Electrical Engineer, Flowmore Limited, Sahibabad, Ghaziabad, U.P., India2B.Tech (EE), M.Tech (Power Systems*), Lecturer, Department of Electrical Engg, Sri RamSwaroopContinue reading “Wind Turbine Operation in Power Systems & Grid Connection Requirements”
Review of Ship Microgrids: System Architectures, Storage Technologies and Power Quality Aspects
Published by Shantha Gamini Jayasinghe1,*, Lasantha Meegahapola2, Nuwantha Fernando2, Zheming Jin3 and Josep M. Guerrero3 1Australian Maritime College, University of Tasmania, Launceston 7250, Australia,2School of Engineering, Royal Melbourne Institute of Technology, Melbourne 3001, Australia; lasantha.meegahapola@rmit.edu.au (L.M.); nuwantha.fernando@rmit.edu.au (N.F.)3Institute of Energy Technology, Aalborg University, Aalborg 9220, Denmark; zhe@et.aau.dk (Z.J.);joz@et.aau.dk (J.M.G.)*Correspondence: shanthaj@utas.edu.au; Tel.: +61-363-249-752 Abstract: Ship microgridsContinue reading “Review of Ship Microgrids: System Architectures, Storage Technologies and Power Quality Aspects”
Power Quality Impacts in a Typical Microgrid
Published by Arangarajan Vinayagam1, Asma Aziz1, KSV Swarna1, Suiyang Khoo1 and Alex Stojcevski2 1Faculty of Science, Engineering and Built Environment, Deakin University, Geelong Australia.2Centre of Technology, RMIT University, Vietnam. Abstract—Microgrid (MG) power system plays an important role to fulfill reliable and secure energy supply to critical loads of communities as well as for communities inContinue reading “Power Quality Impacts in a Typical Microgrid”
China Smart Grid Strategy
Published by China Electric Power Technology Holdings Limited (CEPT), July 2009
Harmonic Response of Distributed Grid Connected Photovoltaic Systems
Published by M. Patsalides is with Dept. of Elec. & Comp. Eng., University of Cyprus, 75 Kallipoleos Avenue, P.O. Box 20537 Nicosia, 1678, Cyprus (e-mail: ee03pm1@ucy.ac.cy). A. Stavrou is with Electricity Authority of Cyprus, Amfipoleos 11, 2025, Nicosia, Cyprus (e-mail: astavrou@eac.com.cy). G. Makrides is with Dept. of Elec. & Comp. Eng., University of Cyprus, 75Continue reading “Harmonic Response of Distributed Grid Connected Photovoltaic Systems”