Power Quality Standards: What You Need to Know

Published by Dranetz Technologies, Inc. Tech Tip: Power Quality Standards: What You Need to Know, Website: Dranetz.com  If you’ve ever connected two different power quality meters to the same circuit and gotten different results, you’re not alone. It’s an age-old issue in power quality monitoring. And when it happens, the obvious question is: which reading should youContinue reading “Power Quality Standards: What You Need to Know”

Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters

Published by 1. Aleksander CHUDY, 2. Paweł A. MAZUREK, Lublin University of Technology ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. The research focused on one–week long measurement of power quality parameters at the connection point of a 450 kW charging station (pantograph type) in the distribution substation. The bus terminal was equipped with 1200 kVA 15.75/0.42Continue reading “Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters”

Understanding the IEEE 519–2014 Standard for Harmonics

Published by Elspec LTD, website: elspec-ltd.com The IEEE 519-2014 standard defines the voltage and current harmonics distortion criteria for the design of electrical systems. The existed voltage and current waveforms in every part of the system are explained in this standard, and the waveform distortion goals for the system designer are established. The standard isContinue reading “Understanding the IEEE 519–2014 Standard for Harmonics”

Dranetz HDPQ Plus & SP Products and IEEE 519-2014

Published by Dranetz Technologies, Inc., Application Note Introduction IEEE Std. 519-2014, IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems is the most current recommended practice from the IEEE related to harmonics measurement and compliance. Although the recommended practices from the IEEE are usually only followed in North America, IEEE 519-2014 is usedContinue reading “Dranetz HDPQ Plus & SP Products and IEEE 519-2014”

Key Changes and Differences between the New IEEE 519- 2014 Standard and IEEE 519-1992

Written by Ian Wallace, Chief Engineer, Power Quality Solutions, TCI® Technical Paper. Introduction IEEE Std 519-2014 is a newly published revision to the IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems. It supersedes the IEEE Std 519-1992 revision. The overarching goal of the 2014 revision is the same as the 1992Continue reading “Key Changes and Differences between the New IEEE 519- 2014 Standard and IEEE 519-1992”

The Effects of Changes to IEEE 519-1992 to 2014

Published by EATON, Powering Business Worldwide, Application Note AP040094EN, Effective November 2014 Introduction Recent changes have been made to IEEE 519. These revisions add clarity to the 1992 document as well as present new definitions, methods and recommendations. This brief summary of changes to IEEE 519 as it pertains to low voltage adjustable frequency drivesContinue reading “The Effects of Changes to IEEE 519-1992 to 2014”