The Influence of Selected Biomedical Research Equipment in the Aspect of Higher Harmonics Generating

Published by Anna KOZIOROWSKA1,2, Dariusz SOBCZYŃSKI3, Wiesława MALSKA3 Uniwersytet Rzeszowski, Wydział Matematyczno – Przyrodniczy, Instytut Techniki (1)Uniwersytet Rzeszowski, Centrum Biotechnologii Stosowanej i Nauk Podstawowych (2)Politechnika Rzeszowska, Wydział Elektrotechniki i Informatyki, Katedra Energoelektroniki i Elektroenergetyki (3) Abstract: Specialized biomedical laboratory equipment, very often use power converters, which are a source of higher harmonics. These devices dependingContinue reading “The Influence of Selected Biomedical Research Equipment in the Aspect of Higher Harmonics Generating”

Electrical Power Quality and Harmonic Concerns

Published by Chuck Gougler, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Fundamentals – Electrical Power Quality and Harmonic Concerns, December 29, 2015 The Problem of Harmonics Harmonics are generated by nonlinear components in electrical systems, which distort the sine wave. Increasing usage of power electronics causes a corresponding increase in voltage distortion, or harmonics.Continue reading “Electrical Power Quality and Harmonic Concerns”

The Measurement of Input Power of Power Supply in Network Disturbed by Low Frequency Distortions

Published by Stanisław GALLA, Arkadiusz SZEWCZYK,Gdansk University of Technology Faculty of Electronics, Telecommunications and Informatics Abstract. In the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elementsContinue reading “The Measurement of Input Power of Power Supply in Network Disturbed by Low Frequency Distortions”

Transmission System Harmonics Study

Published by Electrotek Concepts, Inc., PQSoft Case Study: Transmission System Harmonics Study, Document ID: PQS0501, Date: March 31, 2005. Abstract: A utility presently operates two 16.8 MVAr capacitor banks in a 161/69kV substation. Supplied by this substation are residential, commercial, and industrial loads, including a steel manufacturing facility. For increased voltage support, the utility is investigatingContinue reading “Transmission System Harmonics Study”

Solutions to Mitigate Harmonics

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Solutions to mitigate harmonics There are three different types of solutions to attenuate harmonics: • Modifications in the installation• Special devices in the supply system• Filtering Basic solutions to mitigate harmonics To limit the propagation of harmonics in the distribution network, different solutions are availableContinue reading “Solutions to Mitigate Harmonics”

Harmonics Standards

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Harmonics standards Harmonic emissions are subject to various standards and regulations: • Compatibility standards for distribution networks• Emissions standards applying to the equipment causing harmonics• Recommendations issued by Utilities and applicable to installations In view of rapidly attenuating the effects of harmonics, a tripleContinue reading “Harmonics Standards”

Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements

Published by Ana Maria Blanco1, Britta Heimbach2, Bruno Wartmann2, Jan Meyer1, Marco Mangani2, Martin Oeschger2 1Institute of Electrical Power Systems and High Voltage Engineering, Technische UniversitätDresden, Dresden, Germany2Elektrizitätswerk der Stadt Zürich – EWZ, Zurich, Switzerland1E-mail: ana.blanco@tu-dresden.de 24th International Conference & Exhibition on Electricity Distribution (CIRED), 12-15 June 2017.Session 2: Power quality and electromagnetic compatibility Abstract:Continue reading “Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements”

Selected Aspects of Electrical Equipment Operation with Respect to Power Quality and EMC

Published by Paweł A. MAZUREK, Lublin University of Technology, Institute of Electrical Engineering and Electrotechnologies Abstract. The effectiveness of measures to improve the quality of electricity and the electromagnetic compatibility of electrical equipment is linked to limiting the disturbances introduced by receivers to the power grid and depends on the identification of such interference. TheContinue reading “Selected Aspects of Electrical Equipment Operation with Respect to Power Quality and EMC”

Main Effects of Harmonics in Electrical Installations

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Main effects of harmonics in electrical installations Effects of harmonics – Resonance The simultaneous use of capacitive and inductive devices in distribution networks may result in parallel or series resonance. The origin of the resonance is the very high or very low impedance values atContinue reading “Main Effects of Harmonics in Electrical Installations”

Harmonic Measurement in Electrical Networks

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Harmonic measurement in electrical networks Procedures for harmonic measurement Harmonic measurements are carried out on industrial or commercial sites: • Preventively, to obtain an overall idea on distribution-network status (network mapping),• In view of corrective action, to determine the origin of a disturbance and determineContinue reading “Harmonic Measurement in Electrical Networks”