Published by 1. Sahapong SOMWONG1, 2. Kritsada PUANGSUWAN2,Faculty of Engineering, Rajamangala University of Technology Srivijaya Songkhla, Thailand (1),Faculty of Science and Industrial Technology, Prince of Songkla University, Surat Thani Campus, Surat Thani, Thailand (2) ORCID: (1) 0000-0002-2693-494X; (2) 0000-0003-1613-0611 Abstract. This paper reports the study to design and develop a system for controlling and displayingContinue reading “Power Consumption Control and Monitor using IoT Platform for Smart Office”
Tag Archives: Energy Consumption
The Solar Photovoltaic Energy Capacity for a Parking Project at USTO University
Published by Nessim Abderrahim BOURAHLA1, Mustapha BENGHANEM2, Hamid BOUZEBOUDJA2, Abed BOUADI2, Ali TAHRI2, Higher school of electrical and energy engineering of ran,’’ESGEE’’,Oran, Algeria (1), University of Science and Technology of Oran,’’USTO-MB’’, Oran, Algeria (2)ORCID: 1. 0009-0001-1479-1355 Abstract. A notable shift towards incorporating decentralized energy resources into electrical grids is currently in progress. This article conductsContinue reading “The Solar Photovoltaic Energy Capacity for a Parking Project at USTO University”
Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis
Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2,Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The article is the second part of the analysis of the impact of connecting PV sources to the low voltage distribution network on the riskContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis”
Analysis of Annual Load Variability in the Polish Electric Power System
Published by Kornelia BANASIK1, Andrzej Ł. CHOJNACKI2, Agata KAŹMIERCZYK3, Kielce University of Technology, Faculty of Electrical Engineering, Automatic Control and Computer Science, Department of Power Engineering, Power Electronics and Electrical MachinesORCID: 1. 0000-0002-6629-8650; 2.0000-0002-9227-7538; 3. 0000-0002-4247-4904 Abstract: The paper presents an analysis of the annual variability of power system loads in Poland over a periodContinue reading “Analysis of Annual Load Variability in the Polish Electric Power System”
Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load
Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, Salam Ibrahim khather3, University of Mosul (1), Ninevah University (2,3) ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245, 3. 0000-0002-9082-2360 Abstract. The standalone solar photovoltaic system (SA-SPV) is an appealing alternative for carrying out the electrification process in rural regions through packages in lots of countries. The photovoltaic systems areContinue reading “Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load”
The Optimisation of the Usage of Electricity from a Wind Turbine in a Household
Published by Wiesław MICZULSKI1, Oliwia PERS2, Uniwersytet Zielonogórski, Instytut Metrologii, Elektroniki i Informatyki (1), ETB Solution GmbH (2) ORCID: 1. 0000-0002-8175-0078; 2. 0000-0002-2962-5261 Abstract. The article presents the concept of an algorithm that optimizes energy management in a household. The algorithm optimizes the usage of the energy from a wind turbine and ensures the greatestContinue reading “The Optimisation of the Usage of Electricity from a Wind Turbine in a Household”
High Efficiency Flywheel Motor Generator Model with Frequency Converter Controlled
Published by 1. M.S. ALI 1,2, 2. Mahidur R SARKER 3, 3. Ahmad ASRUL IBRAHIM 1, 4. Ramizi MOHAMED1, 1Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia; 2Electrical Engineering Department, German-Malaysian Institute , Jalan Ilmiah, Taman Universiti,43000, Kajang, Selangor, Malaysia; 3Institute of IR 4.0, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor,Continue reading “High Efficiency Flywheel Motor Generator Model with Frequency Converter Controlled”
An Analysis of Remote Voltage Measurement in the Medium Voltage Cable Networks
Published by 1. Jacek KOZYRA1, 2. Zbigniew ŁUKASIK1, 3. Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, 4. Paweł KASZUBA2, Kazimierz Pulaski University of Technology and Humanities in Radom, (1), Volta Instalacje (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031, 4. 0000-0003-1120-5901 Abstract. Due to changes occurring both in industrial area and in private consumers, availability of modern electric and electronicContinue reading “An Analysis of Remote Voltage Measurement in the Medium Voltage Cable Networks”
Methods of Calculating Solar Insolation for the Assessment of Energy Efficiency of Solar Power Plants
Published by Sergey CHIZHMA, Artyom ZAKHAROV, Immanuel Kant Baltic Federal University (Kaliningrad, Russia) Abstract. The authors explore a number of methods of calculating insolation on a tilted arbitrarily oriented surface and choose the most efficient one for conducting the performance and efficiency analysis of solar power plants. The validity of the method is tested usingContinue reading “Methods of Calculating Solar Insolation for the Assessment of Energy Efficiency of Solar Power Plants”
Loss of Energy in Electrical Networks with Capacitor Banks under Optimal Reactive Power Control
Published by Stanilav S. Girshin1, Aleksandr AY. Bigun1, Nikolay А. Mel’nikov1, Elena V. Petrova1, Vladislav M. Trotsenko1, Dmitry S. Osipov2, Vladimir N. Goryunov1, Omsk State Technical University (1), Yugra State University (2) Russian Federation Abstract. One of the key indicators of the energy efficiency of electrical power systems should include the level of electric powerContinue reading “Loss of Energy in Electrical Networks with Capacitor Banks under Optimal Reactive Power Control”