Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities

Published by 1. Jacek KUSZNIER, 2. Marcin SULKOWSKI, 3. Gabriela Druć, Bialystok University of Technology, Faculty of Electrical Engineering ORCID: 1. 0000-0001-8436-5717; 2. 0000-0002-3079-314X Abstract. The issue of improving the energy efficiency of photovoltaic installations is very important due to the limited location options in public facilities. Therefore, this paper presents the possibilities of improvingContinue reading “Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities”

Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network

Published by Wiktoria GRYCAN, Wroclaw University of Science and Technology, ORCID: 0000-0001-8121-7612 Abstract. Prosumerism is inherently designed to be a tool that alleviates the grid. Still, not every prosumer aligns the consumption profile with the energy generation profile in photovoltaic installations. Therefore, the rapid development of Renewable Energy Sources (RES) in Poland, especially photovoltaic installations,Continue reading “Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network”

Efficient High Voltage Gain Simplified DC-DC Converter for Enhanced Solar Power Harvesting

Published by Shanmugavadivu Natarajan, Department of Electrical and Electronics Engineering, Sri Venkateswara College of Engineering, Sriperumbudur, 602117, India Abstract. This study introduces a novel transformerless high voltage gain DC-DC converter for solar power. It combines a two-inductor boost converter, voltage multiplier, and switched capacitor cells, achieving a remarkable high voltage gain with 98.24% efficiency. AContinue reading “Efficient High Voltage Gain Simplified DC-DC Converter for Enhanced Solar Power Harvesting”

Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources

Published by Ruchika, D.K. Jain, DCRUST, Murthal, Haryana Abstract. Battery energy storage system (BESS) plays a dominant role in large scale penetration of renewable energy sources into the grid. They help in a better match between the demand- supply during standalone mode and the grid connected mode. In this paper, the authors proposed a newContinue reading “Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources”

Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems

Published by 1. Piotr GRYGIEL1,2, 2. Jan TARŁOWSKI2, 3. Krzysztof MIK3, Gdańsk University of Technology (1), Xdisc S.A.,Warsaw, Poland (2), Energy Conversion and Renewable Resources Research Centre, Polish Academy of Sciences, (3) ORCID: 1. 0000-0003-2769-9088; 3. 0000-0002-9510-3066 Abstract. Two types of full-size photovoltaic modules for on-grid systems with maximum DC voltage of 600 V haveContinue reading “Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems”

Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey

Published by 1. Lenin Babu Chilakapati, 2. T Gowri Manohar, SVU College of Engineering, Sri Venkateswara University. ORCID: 1.0000-0001-9749-979X; 2.0000-0003-0441-6022 Abstract. Renewable energy technologies are becoming more and more common for generating electricity because they are environmentally friendly and can meet local electricity needs. They reduce network congestion and also lighten the load on conventionalContinue reading “Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey”

Renewable Energy Collector Transformers

Published by 1. Waldemar ZIOMEK, 2. Krishnamurthy VIJAYAN, PTI Transformers LP, Winnipeg, MB, Canada ORCID: 1. 0000-0002-1216-6513 Abstract. The renewable energy collector transformer (RCT) in a solar station, or a wind farm, transforms the voltage from the collector system to the transmission level voltages. As the primary goal is stepping up the voltage, the RCTContinue reading “Renewable Energy Collector Transformers”

Modelling of Passive Cooling Systems for Solar Panels

Publised by Oleh HOLOVKO1, Adam KONIECZKA2, Adam DĄBROWSKI3, Politechnika Poznańska, Wydział Automatyki, Robotyki i Elektrotechniki (1, 2, 3)ORCID: 2. 0000-0002-0362-3006; 3. 0000-0002-9385-6080O Abstract. This paper proposes a method for evaluating the efficiency of passive cooling systems of solar panels in a type of radiator using CFD simulations. The movement of air through the cooling systemContinue reading “Modelling of Passive Cooling Systems for Solar Panels”

Adaptive Control for Power Management Based on Renewable Energy

Published by Mahmood T. Alkhayyat1, Laith A. Khalaf2, Mohammed Y. Suliman3, Northern Technical University. ORCID: 1. 0000-0001-6119-7845; 2. 0000-0003-1602-6152; 3. 0000-0002-1250-6362 Abstract. A special form of energy system that can be utilized to provide all the energy needed in the globe is the renewable hybrid system. In order to successfully use renewable energy and decreaseContinue reading “Adaptive Control for Power Management Based on Renewable Energy”

The Critical Role of Power Quality Evaluation in Solar Installations

Published by Dranetz Technologies, Inc., Application Note EXECUTIVE SUMMARY As solar photovoltaic (PV) systems become more prevalent in commercial and industrial environments, the emphasis on financial return and concise performance expectations has rightly intensified. However, one often-overlooked aspect of solar deployment is the comprehensive evaluation of power quality (PQ)—both before and after installation. By identifying existing gridContinue reading “The Critical Role of Power Quality Evaluation in Solar Installations”