Security Policy and Good Practice for Implementation of Smart Grid Solutions

Published by Robert CZECHOWSKI, Politechnika Wrocławska, Katedra Elektroenergetyki Abstract. Smart Grid is both a concept and a way to mitigate infrastructural deficiencies and counteract the effects of the growing demand for electrical energy. One of the ways ensuring an increase in power grid’s management efficiency is utilization of the latest communication solutions. Such solutions ensureContinue reading “Security Policy and Good Practice for Implementation of Smart Grid Solutions”

Analysis of Development Directions of Online Diagnostics of Synchronous Generator

Published by Olena RUBANENKO1, Sree Lakshmi GUNDEBOMMU2, Iryna HUNKO3, Zdenek PEROUTKA1, Regional Innovational Center at the Faculty of Electrical Engineering University of West Bohemia (1), Plzen, Czech Republic CVR College of Engineering Mangalpalli (2), Hyderabad, India Vinnytsia National Technical University (3), Vinnytsia, Ukraine Abstract. In this paper the analysis of online diagnostics of synchronous generationsContinue reading “Analysis of Development Directions of Online Diagnostics of Synchronous Generator”

Bridges to Nowhere: Poor Power Quality Prevents Growth

Published by Civian Kiki Massa and Jay Taneja STIMA Lab, University of Massachusetts, Amherst, USA July 2023 Summary: Access to electricity continues to expand worldwide, but even where people are connected to the power grid, they often face challenges including frequent power outages and, less visibly, intermittent periods where electricity is available but only withContinue reading “Bridges to Nowhere: Poor Power Quality Prevents Growth”

An Analysis of Power Quality Problems and its Mitigation

Published by Shafqat Mughal, Neeten Sharma, Pankhuri Kishore Abstract—Power Quality is a major concern of our modern industries and other consumers. Poor quality of supply will affect the performance of customer equipment such as computers, microprocessors adjustable speed drives, power electronic devices, life saving equipment in hospitals, etc. and result in heavy financial losses toContinue reading “An Analysis of Power Quality Problems and its Mitigation”

Novel Fault Current Limiter for Voltage Sag Compensation of Point of Common Coupling

Published by SARAGADAM HEMANTH KUMAR, SH SURESH KUMAR BUDI, Dept. of EEE, Gokul Group of Institutions, Piridi, Bobbili, AP, India. Abstract: Voltage sag is one of the most common power quality disturbances in electrical networks. Voltage sags are incidents that reduce the voltage amplitude for a short time. Voltage Sags are caused by abrupt increasesContinue reading “Novel Fault Current Limiter for Voltage Sag Compensation of Point of Common Coupling”

A Case Study of Sharing the Harmonic Voltage Distortion Responsibility between the Utility and the Consumer

Published by F. H. Costa, I. N. Santos, S. F. P. Silva and J. C. de Oliveira, Group of Power Quality Faculty of Electrical Engineering Federal University of Uberlandia Campus Santa Monica – Av. João Naves de Ávila, 2100 Uberlandia (Brazil). Phone/Fax number:+55 (34) 3239-4733, e-mail: fernandahein@hotmail.com, ivan.ufu@gmail.com, sergio@qes.com.br, jcoliveira@ufu.br Abstract. The aim of thisContinue reading “A Case Study of Sharing the Harmonic Voltage Distortion Responsibility between the Utility and the Consumer”

Power System Harmonics

Published by Olutayo Ogunyemi, School of Science and Engineering, Atlantic International University, Honolulu, HI. Abstract – Good power quality is essential in electrical power network. Power quality is not limited to availability of supply but also include steady frequency value and voltage magnitude and smooth waveform characteristics of the supply (Ogheneovo Johnson, 2016).The present situationContinue reading “Power System Harmonics”

Elspec becomes PQSynergy™ & Power Quality Blog Sponsor

We are pleased to announce that Elspec was a Sponsor for PQSynergyTM International and Conference Exhibition 2024 and Power Quality Blog. It is a privilege to be supported by Elspec. We are grateful to the Elspec team. Elspec is a leading global provider of advanced power quality analyzers, power quality solutions and power monitoring software.Continue reading “Elspec becomes PQSynergy™ & Power Quality Blog Sponsor”

An Introduction to Transformer Harmonic Current Derating Metrics

Published by Richard Lam, CHK Power Quality Pty Ltd. Website: http://www.chkpowerquality.com.au Abstract. Transformer harmonic current derating metrics; Harmonic Loss Factor, K-Factor, and Factor K are introduced, and used to calculate derating factors for dry and oil-filled type transformers. Introduction The introduction of Switched Mode Power Supplies (SMPS) in office equipment and LED lighting, Variable Frequency/SpeedContinue reading “An Introduction to Transformer Harmonic Current Derating Metrics”

Problems of the Current State of Power Quality and Proposals for their Solution

Published by Lidiya Kovernikova, Melentiev Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences, Irkutsk, Russian Federation. Email: kovernikova@isem.irk.ru Abstract. The power quality in Russian electrical networks does not meet the requirements of regulatory documents. Big problems occur in all areas of people’s lives for this reason. Economic damage is oneContinue reading “Problems of the Current State of Power Quality and Proposals for their Solution”