Technical Design Specifications and Criteria for Integrating PV Systems into Distribution Networks in Egypt

Published by Omar H. Abdalla, Fellow Egyptian Society of Engineers, Life Senior Member IEEE. Prof. O. H. Abdalla is with the Department of Electrical Power and Machines Engineering, Faculty of Engineering, 1 Sherief Street, P.O. Technology, P.C. 11792, Helwan, Cairo, Egypt. (e-mail: ohabdalla@ieee.org). Conference Paper: Keynote Lecture (KL-REN-5), International Conference on New Energy and EnvironmentalContinue reading “Technical Design Specifications and Criteria for Integrating PV Systems into Distribution Networks in Egypt”

Harmonic Response of Distributed Grid Connected Photovoltaic Systems

Published by M. Patsalides is with Dept. of Elec. & Comp. Eng., University of Cyprus, 75 Kallipoleos Avenue, P.O. Box 20537 Nicosia, 1678, Cyprus (e-mail: ee03pm1@ucy.ac.cy). A. Stavrou is with Electricity Authority of Cyprus, Amfipoleos 11, 2025, Nicosia, Cyprus (e-mail: astavrou@eac.com.cy). G. Makrides is with Dept. of Elec. & Comp. Eng., University of Cyprus, 75Continue reading “Harmonic Response of Distributed Grid Connected Photovoltaic Systems”

Part 7: AC Power Distribution Systems & Standards (Overcurrent, Fuse & Circuit Breaker)

Published by Nikola Zlatanov* Complete Overcurrent Device Interest in complete overcurrent device selectivity has increased due to the addition of selectivity requirements to articles 700, 701, and 708 of the National Electrical Code (NFPA70). Many users, both commercial and industrial, use fuses and circuit breakers simultaneously. Traditional Time- Current Curve (TCC) analysis is known toContinue reading “Part 7: AC Power Distribution Systems & Standards (Overcurrent, Fuse & Circuit Breaker)”

Part 6: AC Power Distribution Systems & Standards (Power Quality)

Published by Nikola Zlatanov* Power Quality Terms Technical Overview Introduction Sensitive electronic loads deployed today by users require strict requirements for the quality of power delivered to loads. For electronic equipment, power disturbances are defined in terms of amplitude and duration by the electronic equipment operating envelope. Electronic loads may be damaged and disrupted, withContinue reading “Part 6: AC Power Distribution Systems & Standards (Power Quality)”

Part 5: AC Power Distribution Systems & Standards

Published by Nikola Zlatanov* Medium Voltage Equipment Surge Protection Considerations Transformers If the voltage withstand/BIL rating of the transformer is less than that of the switchgear feeding the transformer, surge protection is recommended at the transformer terminals, in line with established practices. In addition, consideration should be given to using surge arresters and/or surge capacitorsContinue reading “Part 5: AC Power Distribution Systems & Standards”

Part 4: AC Power Distribution Systems & Standards

Published by Nikola Zlatanov* Ground Fault Protection Article 230.95 of NEC requires ground- fault protection of equipment shall be provided for solidly grounded wye electrical services of more than 150 V to ground, but not exceeding 600 V phase-to-phase for each service disconnect rated 1000 A or more. The rating of the service disconnect shallContinue reading “Part 4: AC Power Distribution Systems & Standards”

Part 3: AC Power Distribution Systems & Standards

Published by Nikola Zlatanov* Short-Circuit Currents – General The amount of current available in a short-circuit fault is determined by the capacity of the system voltage sources and the impedances of the system, including the fault. Voltage sources include the power supply (utility or on-site generation) plus all rotating machines connected to the system atContinue reading “Part 3: AC Power Distribution Systems & Standards”

Part 1: AC Power Distribution Systems & Standards

Published by Nikola Zlatanov Mr. Nikola Zlatanov spent over 20 years working in the Capital Semiconductor Equipment Industry. His work at Gasonics, Novellus, Lam and KLA-Tencor involved progressing electrical engineering and management roles in disruptive technologies. Nikola received his Undergraduate degree in Electrical Engineering and Computer Systems from Technical University, Sofia, Bulgaria and completed aContinue reading “Part 1: AC Power Distribution Systems & Standards”