Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation

Published by Hana’ A. Rabab’ah 1, Yaser N. Anagreh2, Al-Ahliyya Amman University (1), Yarmouk University (2) ORCID: 1. 0000-0002-1581-7721; 2. 0000-0002-3826-9262 Abstract. This paper presents an integrated stand-alone wind / Photovoltaic (PV) system enhanced with storage system and the required controllers. The proposed scheme concerned with maximum electrical power extracting from the two renewable energyContinue reading “Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation”

A Review of Harmonics Detection and Measurement in Power System

Published by 1. Dnyaneshwar D. Ahire, Professor, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India.2. Snehal R. Durdhavale Student, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India. ABSTRACT – A load is said to be “linear” when it draws a currentContinue reading “A Review of Harmonics Detection and Measurement in Power System”

Assessment of Flange Diffuser Structures to Improve the Power Generation of a Diffuser Augmented Wind Turbine

Published by 1. Yiyin KLISTAFANI, 2. A. M. Shiddiq YUNUS, 3. Muhammad ANSHAR, 4. Sri SUWASTI, State Polytechnic of Ujung Pandang, Indonesia (1) ORCID: 1. 0000-0003-3064-9612; 2. 0000-0002-9599-6941; 3. 0000-0001-5687-5023; 4. 0000-0002-7070-9651 Abstract. Wind energy has become the most popular renewable based power plant for the last decades due to its environment benighted and largeContinue reading “Assessment of Flange Diffuser Structures to Improve the Power Generation of a Diffuser Augmented Wind Turbine”

Problems of the Current State of Power Quality and Proposals for their Solution

Published by Lidiya Kovernikova, Melentiev Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences, Irkutsk, Russian Federation. Email: kovernikova@isem.irk.ru Abstract. The power quality in Russian electrical networks does not meet the requirements of regulatory documents. Big problems occur in all areas of people’s lives for this reason. Economic damage is oneContinue reading “Problems of the Current State of Power Quality and Proposals for their Solution”

Impact of Harmonics on Power Quality and Losses in Power Distribution Systems

Published by M. Jawad Ghorbani, H. Mokhtari**, Dept. of CSEE, West Virginia University, Morgantown, WV, USA, ** Dept. of EE, Sharif University of Technology, Tehran, Iran. ABSTRACT – This paper investigates the harmonic distortion and losses in power distribution systems due to the dramatic increase of nonlinear loads. This paper tries to determine the amountContinue reading “Impact of Harmonics on Power Quality and Losses in Power Distribution Systems”

Impedance Correction Method of Distance Relay on High Voltage Transmission Line

Published by Samira SEGHIR, Tahar BOUTHIBA, Université des Sciences et de la Technologie d’Oran Mohamed BOUDIAF, USTO-MB, Faculté de Génie Electrique, Laboratoire LGEO, BP 1505 El M’Naouer, 31000 Oran, Alegria Abstract. A distance protection relay plays a major role in faults detection in the electric transmission line. The fault resistance has an effect on theContinue reading “Impedance Correction Method of Distance Relay on High Voltage Transmission Line”

Analysis of Thermal Field in 110 kV Cable Systems

Published by Janusz TYKOCKI1, Yong YUE2, Andrzej JORDAN3, The State College of Computer Science and Business Administration in Łomża (1), University of Bedfordshire (2), Visiting professor at University of Bedfordshire (UK), The State College of Computer Science and Business Administration in Łomża (3) Abstract. The paper presents the distribution of temperature field in high voltageContinue reading “Analysis of Thermal Field in 110 kV Cable Systems”

Power Quality Survey in a Distribution System, Standard Procedures and Limitations

Publishd by H. Mokhtari1, S. Hasani and M. Masoudi2, 1Associate Professor Department of Electrical Engineering, Sharif University of Technology, Azadi Ave., Tehran, Iran. Email: mokhtari@sharif.edu, 2Project Engineer and Management, West Azarbayjan Utility, Oroumieh, Iran. Email: sh592b@yahoo.com Abstract ⎯ This paper presents the results of a power quality survey in a distribution system. More than fiftyContinue reading “Power Quality Survey in a Distribution System, Standard Procedures and Limitations”

The Analysis of the Wind Generation Impact on the Power System Stability

Published by Michał PIEKARZ, Politechnika Warszawska, Instytut ElektroenergetykiORCID: 0000-0003-1500-2634 Abstract. The article discusses the issues related to the influence of connecting wind turbines on the angular stability of the power system. Current plans for Poland’s energy transition, climate issues, and the most popular types of wind turbines used in the world were discussed. In theContinue reading “The Analysis of the Wind Generation Impact on the Power System Stability”

Comparative Analysis of the Costs of Medium Voltage Overhead and Cable Lines Failure

Published by Katarzyna GĘBCZYK, Andrzej Ł. CHOJNACKI, Łukasz GRĄKOWSKI, Kornelia BANASIK Kielce, University of Technology, Department of Power Engineering Basics Abstract. The article presents the results of the analysis of the costs of losses at distributors and consumers of electricity, caused by failures of medium voltage overhead and cable power lines operated by domestic distributionContinue reading “Comparative Analysis of the Costs of Medium Voltage Overhead and Cable Lines Failure”