Impact of EV Charging Stations Integration on Power System Performance

Published by Wisam Mohamed Najem1, Shaker M. Khudher2, Omar Sh. Alyozbaky3, Department of Electrical Engineering, College of Engineering, University of Mosul, Iraq (1,2,3) ORCID: 1.0000‐0002‐9611‐6416; 2.0000‐0003‐3158‐7900; 3.0000‐0002‐9735‐1469 Abstract. Electric vehicles partner with clean energy to prevent carbon emissions attributed to internal combustion engine-powered traditional vehicles, gas-based power plants, and other environmental pollution sources. At theContinue reading “Impact of EV Charging Stations Integration on Power System Performance”

Comparing Harmonics Mitigation Techniques

Published by Jonas Persson Comsys AB Fältspatvägen 4, SE-224 78 Lund, Sweden. jonas.persson@comsy, Comparing Harmonics Mitigation Techniques – Revision 3 – 2014-04-08 Abstract— the document at hand compares harmonic mitigation techniques in a range of applications and settings. Theoretical and practical comparisons are made between active and passive series and shunt filters. The overall contextContinue reading “Comparing Harmonics Mitigation Techniques”

Analysis of the Influence of Unequal Current Distribution on the Heating of Parallel Connected LV MOV Surge Arresters

Published by Bartłomiej SZAFRANIAK, Paweł ZYDROŃ, and Łukasz FUŚNIK, AGH University of Science and Technology, Krakow, Poland Abstract. In low-voltage (LV) electrical networks metal-oxide varistor (MOV) surge arresters connected in parallel are often used against overvoltages. The paper presents the results of laboratory experiments, during which pairs of parallel connected MOV surge arresters were subjectedContinue reading “Analysis of the Influence of Unequal Current Distribution on the Heating of Parallel Connected LV MOV Surge Arresters”

Thailand Integrates Large-Scale Wind Farms

Published by C. MADTHARAD, Provincial Electricity Authority (PEA), Thailand. and J. WARMAN, Senergy Econnect Australia. T&D World – Renewables: Thailand Integrates Large-Scale Wind Farms, Sept. 28, 2015. Provincial Electricity Authority address power-quality issues that arise from increasing penetration of renewable energy. In the Kingdom of Thailand, power-quality regulations applicable to small power producers and veryContinue reading “Thailand Integrates Large-Scale Wind Farms”

Potential Transformer Operation, Applications and Accuracy

Published by Alex Roderick, EE Power – Technical Articles: Potential Transformer Operation, Applications and Accuracy, July 14, 2021. Learn about the operation and accuracy of potential transformers. The high voltages typically seen on power lines are a hazard to technicians working on or near the power lines. It is a difficult task to design a voltmeterContinue reading “Potential Transformer Operation, Applications and Accuracy”

Large Scale Proactive Power-Quality Monitoring: An Example from Australia

Published by Sean Elphick, Member, IEEE, Phil Ciufo, Senior Member, IEEE, Gerrard Drury, Vic Smith, Sarath Perera, Senior Member, IEEE, Vic Gosbell, Senior Member, IEEE, University of Wollongong. Abstract – In Australia and many other countries, distribution Network Service Providers (DNSPs) have an obligation to their customers to provide electrical power that is reliable andContinue reading “Large Scale Proactive Power-Quality Monitoring: An Example from Australia”

Comparative Analysis of the Indicators that Concern Power Supply Interruptions for Electricity Consumers for the Selected Distribution System

Published by Małgorzata ŁATKA, Marek NOWAK, Rzeszow University of Technology Abstract. The article presents the results of a comparative analysis of the basic indicators characterizing the interruptions in the supply of electricity. On the basis of generally available reports of selected DSOs, a list of selected indicators was prepared over the years. A comparison ofContinue reading “Comparative Analysis of the Indicators that Concern Power Supply Interruptions for Electricity Consumers for the Selected Distribution System”

Investigation of Power Saving Modes in 10/0.4 kV Distribution Networks

Published by Oleksandr MIROSHNYK1, Andrzej SZAFRANIEC2, Kharkiv Petro Vasylenko National Technical University of Agriculture (1), Kazimierz Pulaski University of Technology and Humanities in Radom, Faculty of Transport, Electrical Engineering and Computer Science (2) Abstract. Operation modes of 0.4/0.23 kV power supply systems are modelled using Monte Carlo method by means of Electronics Workbench software and statisticalContinue reading “Investigation of Power Saving Modes in 10/0.4 kV Distribution Networks”

Power Flow Forecasts: A Status Quo Review. Part 2: Electricity Demand and Power Flow Prediction

Published by Marcin KOPYT, Warsaw University of Technology, Electrical Power Engineering Institute Abstract. Electricity demand predictions are one of the most important tools used for Power System work planning. However, a departure from traditional solutions seems to be inevitable in the light of ever-increasing RES share. This paper is the second of a two-part extensiveContinue reading “Power Flow Forecasts: A Status Quo Review. Part 2: Electricity Demand and Power Flow Prediction”

Monitoring of Electric Arc Furnace Supply Voltage Frequency using Phasor Analysis

Published by Szymon BARCZENTEWICZ, Krzysztof DUDA, Andrzej BIEŃ, AGH University of Science and Technology Abstract. This paper presents the results of measurement experiment conducted in the operating steel plant. Frequency analysis of measured signals revealed an interesting phenomenon, as it happened that after switching off the electric arc furnace, the frequency of the supplying voltageContinue reading “Monitoring of Electric Arc Furnace Supply Voltage Frequency using Phasor Analysis”