Transformer Inspection and Testing

Published by Alex Roderick, EE Power – Technical Articles: Transformer Inspection and Testing, December 17, 2021. Installing a transformer is more than just connecting the wires, according to the wiring diagram. The first part of the installation process includes an initial inspection and testing of the transformer when it is received from the factory or warehouse.Continue reading “Transformer Inspection and Testing”

Improving the Charging Technology for Electric Vehicles

Published by Peter Lutter, EE Power – Technical Articles: Improving the Charging Technology for Electric Vehicles, September 26, 2018. This article discusses the concept of universal inductive energy transmission and its possible applications and implications. With the development of a universal inductive charging system, Finepower GmbH near Munich underpins its leading position in power electronics andContinue reading “Improving the Charging Technology for Electric Vehicles”

Introduction to Energy Meter Calibration

Published by Simon Mugo, EE Power – Technical Articles: Introduction to Energy Meter Calibration, November 04, 2022. This article will guide engineers and technicians through procedures, precautions, and the importance of carrying out electrical energy meter calibration. All electrical and electronic measuring equipment is prone to errors caused by external or internal factors. The errors can be removedContinue reading “Introduction to Energy Meter Calibration”

Specifics of Hydropower Plant Management in Isolated Power Systems

Published by Sherkhon SULTONOV1 , Murodbek SAFARALIEV2 , Sergey KOKIN2 , Stepan DMITRIEV2 , Inga ZICMANE3 , Shokhin DZHURAEV1,4 Tajik Technical University, Tajikistan(1), Ural Federal University (2), Riga Technical University, Latvia (3), Branch of the National Research University ‘Moscow Power Engineering Institute’ in Dushanbe City (4)ORCID: 1. 0000-0003-2322-5272; 2. 0000-0003-3433-9742; 3. 0000-0001-7493-172X; 4. 0000-0001-8781-2383; 5.Continue reading “Specifics of Hydropower Plant Management in Isolated Power Systems”

Substation Grounding Basics: Step, Touch, and Transferred Voltages

Published by Lorenzo Mari, EE Power – Technical Articles: Substation Grounding Basics: Step, Touch, and Transferred Voltages, October 09, 2020. Learn about Earth potential gradients and shock situations in substations. The conduction of high currents to ground in substations due to atmospheric disturbances or equipment failures generates potential gradients on Earth’s surface that are a threatContinue reading “Substation Grounding Basics: Step, Touch, and Transferred Voltages”

6 Techniques for Controlling Harmonic Distortion

Published by Simon Mugo, EE Power – Technical Articles: 6 Techniques for Controlling Harmonic Distortion, May 15, 2023. Harmonics–currents or voltages at a multiple of the power systems’ fundamental frequencies– originate from non-linear loads in power systems. This article will introduce six techniques necessary to reduce harmonic distortion. The earliest method of controlling problems associated withContinue reading “6 Techniques for Controlling Harmonic Distortion”

Combining Waveforms in a Power System to Cancel Harmonic Components

Published by Alex Roderick, EE Power – Technical Articles: Combining Waveforms in a Power System to Cancel Harmonic Components, August 23, 2021. Harmonics can cause transformers to fail, motors to burn out, circuit breakers to trip (nuisance tripping), and neutral conductors and other parts of a power distribution system to overheat. Severe overheating leads to electricalContinue reading “Combining Waveforms in a Power System to Cancel Harmonic Components”

Power Flow Forecasts: A Status Quo Review. Part 2: Electricity Demand and Power Flow Prediction

Published by Marcin KOPYT, Warsaw University of Technology, Electrical Power Engineering Institute Abstract. Electricity demand predictions are one of the most important tools used for Power System work planning. However, a departure from traditional solutions seems to be inevitable in the light of ever-increasing RES share. This paper is the second of a two-part extensiveContinue reading “Power Flow Forecasts: A Status Quo Review. Part 2: Electricity Demand and Power Flow Prediction”

Energy Storage Systems in Electrified Transportation

Published by Anushree Ramanath, EE Power – Technical Articles: Energy Storage Systems in Electrified Transportation, November 08, 2021. This article explains how battery packs utilize an energy management system for protection, control, and estimation. Electrification is the most promising solution to enable a more sustainable and environmentally friendly transportation system. Traditionally, electrical energy storage forContinue reading “Energy Storage Systems in Electrified Transportation”

Electric Power Quality Measurement

Published by Alessandro Ferrero, Dipartimento di Elettrotecnica – Politecnico di Milano – Piazza Leonardo da Vinci 32 – 20133 Milano – Italy Abstract – The proliferation of non-linear and time-variant loads is causing a number of disturbances on the electric network, from a more and more significant distortion of both currents and voltages, to transientContinue reading “Electric Power Quality Measurement”