Published by Electrotek Concepts, Inc., PQSoft Case Study: Feeder Lightning Transients, Document ID: PQS1101, Date: March 15, 2011. Abstract: Lightning strokes to exposed utility transmission or distribution circuits can inject a significant amount of energy into the power system in a very short time, causing deviations in voltages and currents which persist until the excess energyContinue reading “Feeder Lightning Transients”
Author Archives: PQBlog
Steel Plant Transformer Operational Issues
Published by Tadeusz GLINKA1,2, Marek GLINKA2Politechnika Śląska w Gliwicach (1), BOBRME Komel (2) Abstract. Design of steel-plant furnace three-phase transformer (110 kV/(350 to 500) V, 50 kA) and its operating conditions are described in the paper. After three months of operation this transformer failed. Cause of failure, its course and damage to transformer winding areContinue reading “Steel Plant Transformer Operational Issues”
Transmission 101: The Fundamentals of High Voltage Transmission
Published by Adriann (Andee) McCoy, Vice President, Western Region, Smart WiresEmail: Andee@smartwires.comDate: February 16, 2017 Presented by WIRES – a national coalition of entities dedicated to investment in a strong, well-planned and environmentally beneficial electricity high voltage transmission system in the US.
Effect of Synchronous Closing Control on Capacitor Energizing Transients
Published by Electrotek Concepts, Inc., PQSoft Case Study: Effect of Synchronous Closing Control on Capacitor Energizing Transients, Document ID: PQS0903, Date: October 15, 2009. Abstract: The application of utility capacitor banks has long been accepted as a necessary step in the efficient design of utility power systems. In addition, capacitor switching is generally considered a normalContinue reading “Effect of Synchronous Closing Control on Capacitor Energizing Transients”
PQ Monitoring in Selected Networks of Czech Republic
Published by Petr KREJCI1, Pavel SANTARIUS1, Radovan HAJOVSKY1, Richard VELICKA1, Radim CUMPELIK2VSB – Technical University of Ostrava, Czech Republic (1), CEZ, a.s., Czech Republic (2) Abstract. In the paper, the results of the complex monitoring of selected PQ parameters during 12 years will be summarized together with the comparison of the changes of parameters afterContinue reading “PQ Monitoring in Selected Networks of Czech Republic”
Distribution System Transient Measurement Data Evaluation
Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution System Transient Measurement Data Evaluation, Document ID: PQS1012, Date: October 15, 2010. Abstract: This case study presents a utility distribution system transient measurement data analysis. The distribution system included a number of feeders that supplied a mix of residential, commercial, and industrial customers. The causes of theContinue reading “Distribution System Transient Measurement Data Evaluation”
Smart Meter and Cost Experiment
Published by Mehmet Sait CENGİZ1University of Yüzüncü Yıl (1) Abstract. System that all stakeholders compound the activities (production, transmission, distribution, sale, consumption) to product and to consume quality, constant, reliable and economic electric energy is called Smart Grid (SG) in electric. SG, which its most important component smart meter (Smart Metering-SM), are advanced energy meteringContinue reading “Smart Meter and Cost Experiment”
Distribution Feeder Wind Turbine Generator Analysis
Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Feeder Wind Turbine Generator Analysis, Document ID: PQS1206, Date: January 26, 2012. Abstract: This case study presents a distribution feeder wind turbine generator analysis. The investigation included several potential causes of turbine and feeder overcurrents and overvoltages, including wind speed variations, cut-out and cut-in switching operations, groundContinue reading “Distribution Feeder Wind Turbine Generator Analysis”
The Effect of PWM Frequency on the Effectiveness of Protection Against Electric Shock using Residual Current Devices
Published by Stanisław CZAPP , Gdańsk University of Technology, Faculty of Electrical and Control Engineering Abstract. In the paper spectral analysis of the distorted earth fault currents in circuits with variable speed drives is performed. Effectiveness of protection against electric shock using residual current devices in circuits with variable speed drives for various PWM frequenciesContinue reading “The Effect of PWM Frequency on the Effectiveness of Protection Against Electric Shock using Residual Current Devices”
A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications
Published by Yang HAN1, Lin XU2University of Electronic Science and Technology of China (1), Shanghai Jiao Tong University (2) Abstract. This paper presents the survey of the smart grid technologies, including the background, motivation and practical applications. The driving forces for the smart grid technologies are presented, including the blackout, global energy crisis and environmentalContinue reading “A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications”