Published by Electrotek Concepts, Inc., PQSoft Case Study: Wind Plant IEEE Std. 519 Compliance Evaluation, Document ID: PQS1201, Date: January 25, 2012. Abstract: This case study presents the results for a wind plant substation IEEE Std. 519 harmonic measurement compliance evaluation. The wind plant substation supplied 65 wind turbine generators and the power quality monitor wasContinue reading “Wind Plant IEEE Std. 519 Compliance Evaluation”
Tag Archives: Wind Turbines
Seasonality Effect on Working and Prediction of the Production of Electricity in Onshore Wind Farm
Published by Mateusz DUTKA1, Bogusław ŚWIĄTEK1, AGH University of Science and Technology, Department of Power Electronics and Energy Control Systems (1) Abstract. This paper describes relevant issues of the energy prediction from onshore wind farms. The use of a neural network to forecast wind power production and its resistance to changing seasons is examined. DifferentContinue reading “Seasonality Effect on Working and Prediction of the Production of Electricity in Onshore Wind Farm”
Solar-Wind Hybrid Power System Analysis Using Homer for Duhok, Iraq
Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, University of Mosul (1), Ninevah University(2) Iraq. ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245 Abstract. The government of Iraq recently joined the Paris Climate Agreement, it has now begun to encourage the participation of small and large consumers to generate electricity from renewable energy resources. This article analyses aContinue reading “Solar-Wind Hybrid Power System Analysis Using Homer for Duhok, Iraq”
Improved Control Strategy of Wind Energy Conversion System with PMSG during Low Voltage Sags
Published by Piotr GAJEWSKI, Wrocław University of Science and Technology, Department of Electrical Machines, Drives and Measurements Abstract. The paper presents the improved control strategy for Wind Energy Conversion System (WECS) during voltage sags. The considered back-to-back converter system includes: Ma-chine Side Converter (MSC) and Grid Side Converter (GSC) with control circuits. To the windContinue reading “Improved Control Strategy of Wind Energy Conversion System with PMSG during Low Voltage Sags”
Wind Farm and System Modelling Evaluation in Harmonic Propagation Studies
Published by G. A. Mendonça1, H. A. Pereira1,2 and S. R. Silva1,1 Graduate Program in Electrical Engineering – Universidade Federal de Minas Gerais Av. Antônio Carlos 6627, 31270-901, Belo Horizonte, MG, Brazil. Phone: +55-31-3409-4842, e-mail: gforti@gmail.com, heverton.pereira@ufv.com.br, selenios@dee.ufmg.br2 Department of Electrical Engineering, Universidade Federal de Viçosa Av. P.H.Rolfs S/N,36570-000, Viçosa, MG, Brazil Abstract. Wind powerContinue reading “Wind Farm and System Modelling Evaluation in Harmonic Propagation Studies”
Prediction of Electricity Production in Island Operation under the different Wind Generation Modes
Published by Dušan MEDVEĎ1, Zsolt ČONKA1 Marek PAVLIK1, Ján ZBOJOVSKY1,Michal KOLCUN1,Michal IVANČÁK1, Technical University of Košice, Department of Electric Power Engineering, Mäsiarska 74, 04001 Košice, Slovakia (1) Abstract. This paper deals with the prediction of electricity generation in particular part of the network (island operation) where were considered various regimes of the wind power plantContinue reading “Prediction of Electricity Production in Island Operation under the different Wind Generation Modes”
Assessment of the Impact of the Micro Wind Turbine on the Power Quality in the Distribution Network
Published by Marek GAŁA, Andrzej JĄDERKO, Politechnika Częstochowska, Wydział Elektryczny Abstract. The article presents the principles of measurements and assessment of power quality characteristics, with the power supplied by the micro wind turbine connected to the distribution network. It describes the basic technical parameters of the vertical axis micro wind turbine 10 kW and theContinue reading “Assessment of the Impact of the Micro Wind Turbine on the Power Quality in the Distribution Network”
Designing a Passive Filter for Reducing Harmonic Distortion in the Hybrid Micro-grid Including Wind Turbine, Solar Cell and Nonlinear Load
Published by Ali BAGHERI, Mohsen ALIZADEH, Department of Electrical Engineering, Yadegar -e- Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran Abstract. One of the most important indices of power quality in distribution grids is the harmonic distortion, which can affect the reliability of the micro-grid. On the other hand, the growth ofContinue reading “Designing a Passive Filter for Reducing Harmonic Distortion in the Hybrid Micro-grid Including Wind Turbine, Solar Cell and Nonlinear Load”
Grounding of Wind Power Systems and Wind Power Generators
Published by Sergio Panetta, International Association of Electrical Inspectors (IAEI) Magazine, Evolving Technologies – Grounding of Wind Power Systems and Wind Power Generators, May 16, 2010 Power continuity is essential in wind power projects where a tripped overcurrent device due to ground fault can have serious economic or operational consequences. An arcing phase-to-ground fault canContinue reading “Grounding of Wind Power Systems and Wind Power Generators”
Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements
Published by Ana Maria Blanco1, Britta Heimbach2, Bruno Wartmann2, Jan Meyer1, Marco Mangani2, Martin Oeschger2 1Institute of Electrical Power Systems and High Voltage Engineering, Technische UniversitätDresden, Dresden, Germany2Elektrizitätswerk der Stadt Zürich – EWZ, Zurich, Switzerland1E-mail: ana.blanco@tu-dresden.de 24th International Conference & Exhibition on Electricity Distribution (CIRED), 12-15 June 2017.Session 2: Power quality and electromagnetic compatibility Abstract:Continue reading “Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements”