Published by Aliashraf BAKHTIYAROV1, Gulshan ABDULLAYEVA2, Hamid PIRIYEV3, Azerbaijan State Oil and Industry University ORCID: 2. 0000-0003-0168-9623; 3. 0009-0000-2992-6358 Abstract. In today’s world, when the role of renewable energy sources is becoming increasingly important in the context of combating climate change and reducing dependence on fossil fuels, wind energy occupies a leading position. Wind turbinesContinue reading “Analysis of Electrical Generators for Wind Electric Installations”
Tag Archives: Wind Turbines
Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources
Published by Ruchika, D.K. Jain, DCRUST, Murthal, Haryana Abstract. Battery energy storage system (BESS) plays a dominant role in large scale penetration of renewable energy sources into the grid. They help in a better match between the demand- supply during standalone mode and the grid connected mode. In this paper, the authors proposed a newContinue reading “Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources”
Research of Methods Power Control of Wind Turbines
Published by Nijat Mammadov1, Ilkin Marufov2, Saadat Shikhaliyeva, Gulnara Aliyeva, Saida Kerimova,Azerbaijan State Oil and Industry UniversityORCID: 1. 0000-0001-6555-3632; 2. 0000-0002-3143-0113 Abstract. Currently, renewable energy sources play an important role in the global energy balance. Among them, wind electric installations occupy a special place. As wind turbines develop and their power increases, their design alsoContinue reading “Research of Methods Power Control of Wind Turbines”
Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey
Published by 1. Lenin Babu Chilakapati, 2. T Gowri Manohar, SVU College of Engineering, Sri Venkateswara University. ORCID: 1.0000-0001-9749-979X; 2.0000-0003-0441-6022 Abstract. Renewable energy technologies are becoming more and more common for generating electricity because they are environmentally friendly and can meet local electricity needs. They reduce network congestion and also lighten the load on conventionalContinue reading “Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey”
Renewable Energy Collector Transformers
Published by 1. Waldemar ZIOMEK, 2. Krishnamurthy VIJAYAN, PTI Transformers LP, Winnipeg, MB, Canada ORCID: 1. 0000-0002-1216-6513 Abstract. The renewable energy collector transformer (RCT) in a solar station, or a wind farm, transforms the voltage from the collector system to the transmission level voltages. As the primary goal is stepping up the voltage, the RCTContinue reading “Renewable Energy Collector Transformers”
Research of Lightning Protection Systems for Wind Electric Installations
Published by Nijat Mammadov1, Najiba Piriyeva2, Shukufa Ismayilova3, Azerbaijan State Oil and Industry University ORCID: 1. 0000-0001-6555-3632; 2. 0000-0002-8990-1803 Abstract. The purpose of this study is to analyze the lightning protection systems of wind turbines. One of the main causes of damage to wind electric installations is lightning strikes. In order to reduce the likelihoodContinue reading “Research of Lightning Protection Systems for Wind Electric Installations”
Protection of DC Microgrid using ΔCB
Published by 1. Marwan R. Abed, 2. Oday A. Ahmed, 3. Ghassan A. Bilal, University of Technology Iraq, Baghdad, ORCID: 1. 0000-0002-1257-2810; 2. 0000-0001-7214-3412; 3. 0000-0002-5090-103X Abstract. When implementing a DC distribution network, it is much easier to integrate distributed energy sources than it is with an ac grid. Furthermore, the efficiency and reliability ofContinue reading “Protection of DC Microgrid using ΔCB”
Adaptive Control for Power Management Based on Renewable Energy
Published by Mahmood T. Alkhayyat1, Laith A. Khalaf2, Mohammed Y. Suliman3, Northern Technical University. ORCID: 1. 0000-0001-6119-7845; 2. 0000-0003-1602-6152; 3. 0000-0002-1250-6362 Abstract. A special form of energy system that can be utilized to provide all the energy needed in the globe is the renewable hybrid system. In order to successfully use renewable energy and decreaseContinue reading “Adaptive Control for Power Management Based on Renewable Energy”
Increasing Penetration of Renewable Sources into Power System in Poland
Published by Tomasz SIEŃKO1, Jerzy SZCZEPANIK2, Cracow University of Technology, Krakow Poland (1), Cracow University of Technology, Krakow Poland (2) ORCID: 1. 0000-0002-3645-5694; 2. 0000-0001-5633-8359 Abstract. Increased Penetration of the Polish Power Supply System by renewable sources (RES) leads to a number of serious and new problems. The problems are associated with evacuating energy fromContinue reading “Increasing Penetration of Renewable Sources into Power System in Poland”
The Optimisation of the Usage of Electricity from a Wind Turbine in a Household
Published by Wiesław MICZULSKI1, Oliwia PERS2, Uniwersytet Zielonogórski, Instytut Metrologii, Elektroniki i Informatyki (1), ETB Solution GmbH (2) ORCID: 1. 0000-0002-8175-0078; 2. 0000-0002-2962-5261 Abstract. The article presents the concept of an algorithm that optimizes energy management in a household. The algorithm optimizes the usage of the energy from a wind turbine and ensures the greatestContinue reading “The Optimisation of the Usage of Electricity from a Wind Turbine in a Household”