Published by 1. Bahri PREBREZA, 2. Nuri BERISHA1*, 3. Bashkim STATOVCI, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0003-1950-026X; 2. 0000-0001-8615-637X; 3. 0000-0002-6840-0778 Abstract. Power systems might experience electrical problems or power outages, due to atmospheric discharges. The quality of the protection from atmospheric overvoltages will increase the life of the equipmentContinue reading “Analysis of Switching Overvoltages and Protection from Atmospheric Overvoltages for 400kV Switchgears in the Kosovo Power System using ATP/EMTP”
Tag Archives: Transients
PQ Secure
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se PQ Secure – Power Quality Management System The quality of your power is extremely important as disturbances or short outages can cause major problems for your equipment and systems. We have created a Power Quality Management System that will assist you in monitoring your systemContinue reading “PQ Secure”
Unipower – About Power Quality
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Power quality is a generic term for disturbance-free electricity supply. Deviation from voltage sinusoidal waveform (50 Hz), which may result in equipment being disturbed or damaged, is to be regarded as a power quality disturbance. This means that the more sensitive equipment you connect toContinue reading “Unipower – About Power Quality”
Transient Detection using Peak Detectors
Published by Jonny Carlsson, Unipower AB, http://www.unipower.se Background The main problem with transients in the electrical network is that a high voltage potential might break the isolation barrier in for example cables or other equipment in the electrical network. It may also harm semiconductors that are sensitive of high voltage. A transient voltage is byContinue reading “Transient Detection using Peak Detectors”
Extra High Voltage Transmission Line Lightening Protection using Surge Arrester
Published by Ali HAMOODI, Rasha MOHAMMED, Bashar SALIH, Northern Technical University, Engineering technical college Abstract. The objective of this work was to protect the transmission line (T.L.) from the lightning effect. In the last decades, several methodologies have been employed for the rise of lightning performance on the T.L Lightning with high values of currentContinue reading “Extra High Voltage Transmission Line Lightening Protection using Surge Arrester”
An Analysis of Power Quality Problems and its Mitigation
Published by Shafqat Mughal, Neeten Sharma, Pankhuri Kishore Abstract—Power Quality is a major concern of our modern industries and other consumers. Poor quality of supply will affect the performance of customer equipment such as computers, microprocessors adjustable speed drives, power electronic devices, life saving equipment in hospitals, etc. and result in heavy financial losses toContinue reading “An Analysis of Power Quality Problems and its Mitigation”
Comparison of Two Concepts for Modeling of Lightning Strike into Overhead Line
Published by Karol ANISEROWICZ, Politechnika Białostocka, Wydział ElektrycznyORCID: 0000-0001-8895-3954 Abstract. The paper presents a comparison of results of determining the lightning current flow in the shield wires of a high voltage line, using the model of lightning in the form of a lumped current generator and the antenna model, which takes the electromagnetic coupling intoContinue reading “Comparison of Two Concepts for Modeling of Lightning Strike into Overhead Line”
Static Synchronous Compensator and Superconducting Fault Current Limiter for Power Transmission System Transient Stability Regulation Including Wind Generator
Published by Abdelkrim ZEBAR, Department of Electrical Engineering, Faculty of technology, Ferhat Abbas Setif 1 University, Setif, Algeria Abstract. The increase of environmental pollution and the decreasing of the energy is extremely related to social progress. The resolution of the environment pollution depends on renewable energy such as wind energy system. Though, that system isContinue reading “Static Synchronous Compensator and Superconducting Fault Current Limiter for Power Transmission System Transient Stability Regulation Including Wind Generator”
Analysis of Transient Waveforms in a Power System at Asymmetrical Short-Circuits
Published by Piotr PRUSKI, Stefan PASZEK, Silesian University of Technology Abstract. In the paper, there is presented the analysis of disturbance waveforms of a synchronous generator operating in a single-machine power system consisting of a generating unit connected by a high-voltage power line to a bus. There are considered disturbances in the form of symmetricalContinue reading “Analysis of Transient Waveforms in a Power System at Asymmetrical Short-Circuits”
Modeling the Transient Response of Lightning Current on Grounding Systems Wind Turbines
Published by Amina DJABOREBBI, Boubakeur ZEGNINI, Djillali MAHI, Amar TELIDJI University of Laghouat, PoBox 37 G, Mkam Laghouat 03000, Algeria. Abstract. The paper deals with transient analysis of grounding systems wind turbines. To improve the accuracy of lightning impact studies on wind power grid generation, it is necessary to develop faster, more accurate simulation toolsContinue reading “Modeling the Transient Response of Lightning Current on Grounding Systems Wind Turbines”