Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2,Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The article is the second part of the analysis of the impact of connecting PV sources to the low voltage distribution network on the riskContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis”
Tag Archives: solar-power
Analysing the Performance of H5 Inverters in a Photovoltaic System
Published by 1. Mohd Sanusi Bin Mohd Mokhtar1, 2. Mohd Shafie Bin Bakar2, 3. Mohd Shawal Bin Jadin2, Paya Besar Community College (1), Faculty of Electrical and Electronics Engineering Technology, Universiti Malaysia Pahang (UMP) (2) ORCID: 2. 0000-0003-2905-6449; 3.0000-0001-6253-7821 Abstract. In this paper, a simulation study on H5 topology is presented. H5 topology is aContinue reading “Analysing the Performance of H5 Inverters in a Photovoltaic System”
Electricity Transportation using HVDC Technology for Algerian Southern Sun Power Plants
Published by 1. Mohammed SAAIDIA, 2. Abdelghani GUECHI, 3. Nedjem-Eddine BENCHOUIA, University Mohamed-Cherif Messaadia of Souk-Ahras . ORCID: 1. 0000-0002-7778-8591; 3. 0000-0002-4761-940 Abstract. Algeria is worldly known as one of the big producers and exporters of fossil fuels. However, by developing an adequate energy policy, it could become one of the great sun power (SP)Continue reading “Electricity Transportation using HVDC Technology for Algerian Southern Sun Power Plants”
Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load
Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, Salam Ibrahim khather3, University of Mosul (1), Ninevah University (2,3) ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245, 3. 0000-0002-9082-2360 Abstract. The standalone solar photovoltaic system (SA-SPV) is an appealing alternative for carrying out the electrification process in rural regions through packages in lots of countries. The photovoltaic systems areContinue reading “Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load”
Power Quality Improvement in Distributed Generation System under varying Load Conditions using PWM and Hysteresis Controller
Published Vijayshree G1, Sumathi S2, RNSIT, Bangalore,Karnataka,India(1). RNSIT, Bangalore,Karnataka, India(2) Abstract – This paper proposes a power system network modeled using a microgrid, integrated with wind and solar photovoltaic (PV) resources, along with the battery energy storage system (BESS) connected to the three-phase grid feeding the linear and nonlinear load. The simulation is carried outContinue reading “Power Quality Improvement in Distributed Generation System under varying Load Conditions using PWM and Hysteresis Controller”
Active and Reactive Power Control in a Three-Phase Photovoltaic Inverter
Published by 1.Adnan Majeed Abed1, 2. Afaneen Anwer Alkhazraji2, 3. Shatha S. Abdulla3, University of Technology, Iraq, Baghdad (1), University of Technology, Iraq, Baghdad (2), University of Technology, Iraq, Baghdad (3) ORCID: 1.0000-0002-6558-9552; 2.0000-0003-3995-8307;3. 0000-0001-5493-2485 Abstract. In most nations, grid-connected buildings with solar systems are expanding. Several sites in the system network have high PVContinue reading “Active and Reactive Power Control in a Three-Phase Photovoltaic Inverter”
Analysis of the Impact of Wind Turbine Power Characteristics on the Amount of Generated Energy
Published by Damian GŁUCHY1, Grzegorz TRZMIEL2, Poznan University of TechnologyORCID: 1. 0000-0003-2725-2614; 2. 0000-0002-3622-8889 Abstract. In the following article the impact of power characteristics of wind turbines on the total amount of generated power is introduced. The review of scientific literature suggested the need of further analysis of this issue. In order to do so,Continue reading “Analysis of the Impact of Wind Turbine Power Characteristics on the Amount of Generated Energy”
A Photovoltaic System Maximum Power Point Tracking by using Artificial Neural Network
Published by KARRI HEMANTH KUMAR1, GADI VENKATA SIVA KRISHNA RAO2, Department of Electrical Engineering, Andhra university college of Engineering (A), Andhra university, Vishakhapatnam, India. ORCID: 1. 0000-0001-6198-999X. ORCID: 2. 0000-0003-4314-4816 Abstract: The electrical energy from the sun can be extracted using solar photovoltaic (PV) modules. This energy can be maximized if the connected load resistanceContinue reading “A Photovoltaic System Maximum Power Point Tracking by using Artificial Neural Network”
Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation
Published by Hana’ A. Rabab’ah 1, Yaser N. Anagreh2, Al-Ahliyya Amman University (1), Yarmouk University (2) ORCID: 1. 0000-0002-1581-7721; 2. 0000-0002-3826-9262 Abstract. This paper presents an integrated stand-alone wind / Photovoltaic (PV) system enhanced with storage system and the required controllers. The proposed scheme concerned with maximum electrical power extracting from the two renewable energyContinue reading “Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation”
Energy Management for a New Power System Configuration of Base Transceiver Station (BTS) Destined to Remote and Isolated Areas
Published by 1. Abdallah MOUGAY1, 2. Mohamed KHATIR1, 3. Mohamed FLITTI1, 4. Sid-Ahmed ZIDI1, 5. Ahmed Ganoune2, ICEPS Laboratory, Department of Electrical Engineering, Djillali Liabes University, Sidi Bel Abbes, 22000, Algeria (1) Department of Electrical Engineering, Taher Moulay University, Saida, 20000, Algeria (2) . ORCID: 1. : 0000-0001-6676-4466; 2. 0000-0002-3906-9131; 3. 0000-0002-7469-20174. : 0000-0001-7224-8812; 5.Continue reading “Energy Management for a New Power System Configuration of Base Transceiver Station (BTS) Destined to Remote and Isolated Areas”