Published by Sean Elphick, Member, IEEE, Phil Ciufo, Senior Member, IEEE, Gerrard Drury, Vic Smith, Sarath Perera, Senior Member, IEEE, Vic Gosbell, Senior Member, IEEE, University of Wollongong. Abstract – In Australia and many other countries, distribution Network Service Providers (DNSPs) have an obligation to their customers to provide electrical power that is reliable andContinue reading “Large Scale Proactive Power-Quality Monitoring: An Example from Australia”
Tag Archives: Harmonics
Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant
Published by Marian HYLA, Silesian University of Technology, Department of Power Electronics, Electrical Drives and Robotics. ORCID: 0000-0001-6466-7398 Abstract. The paper presents the issues of the influence on the supply electrical power grid of the thyristor rectifier supplying high power receivers such as a shaft hoisting machines in mining. The current distortion influence of theContinue reading “Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant”
Harmonic Measurement and Analysis during Electric Vehicle Charging
Published by Mohd Zamri Che Wanik1, Mohd FadzilMohd Siam1, Afida Ayob2, Subiyanto2, Azah Mohamed2, Abu HanifahAzit3, SaharuddinSulaiman3, Mohamed Azrin Mohamed Ali4, Zahrul Faizi Hussein1, Ahmad Kamil MatHussin1, 1TNB Research Malaysia, Malaysia, 2Power System Research Group, Universiti Kebangsaan Malaysia, Malaysia, 3TNB Distribution Malaysia, Malaysia, 4Malaysian Green Technology Corporation, Bandar BaruBangi, Malaysia. Email: mzamri@tnbr.com.my ABSTRACT This paperContinue reading “Harmonic Measurement and Analysis during Electric Vehicle Charging”
A Review of the Harmonic and Unbalance Effects in Electrical Distribution Networks due to EV Charging
Published by Lauri Kütt, Eero Saarijärvi, Matti Lehtonen, Department of Electrical Engineering Aalto University School of Electrical Engineering, Espoo, Finland. lauri.kutt@aalto.fi, eero.saarijarvi@aalto.fiHeigo Mõlder, Jaan Niitsoo, Department of Electrical Engineering, Tallinn University of Technology Tallinn, Estonia Abstract—For wide use of electric vehicles (EVs), there are different aspects of the electric power system to consider for makingContinue reading “A Review of the Harmonic and Unbalance Effects in Electrical Distribution Networks due to EV Charging”
Power Quality — Basics Commercial Buildings
Published by HSB, Power quality — basics Commercial property, One State Street P.O. Box 5024 Hartford, CT 06102-5024 Tel: (800) 472-1866. Website: HSB.com Introduction Power quality is a general term used to describe the compatibility between connected equipment and its electrical supply. The supply system can be affected by changes to the frequency or amplitudeContinue reading “Power Quality — Basics Commercial Buildings”
Understanding Telephone Interference Factor
Published by David Horning, March 2013. Power Monitors, Inc., White Paper: Understanding Telephone Interference Factor Abstract. Harmonic distortion that is produced from power conversion systems can cause interference on analog telephone lines. The degree of telephone interference can be expressed in terms of the Telephone Interference Factor (TIF). This white paper will discuss how interference isContinue reading “Understanding Telephone Interference Factor”
Multi-Servers System with Firebird Database for Automatic Reactive Power Compensation
Published by Marian HYLA, Silesian University of Technology, Department of Power Electronics, Electrical Drives and Robotics Abstract. The paper presents the concept, implementation and operational effects of the multi-servers automatic reactive power compensation system in 6 kV industry electrical power grid. As controlled reactive power compensators were used synchronous motors, capacitors’ banks and passive filtersContinue reading “Multi-Servers System with Firebird Database for Automatic Reactive Power Compensation”
Steps to Find the Source of Harmonics
Published by David Horning, November 2014. Power Monitors, Inc., White Paper: Steps to Find the Source of Harmonics Abstract. Harmonics are “Non-Linear” current or voltage in an electrical system. Any waveform that deviates from a perfect sine wave has harmonics. Any nonlinear load draws harmonic currents and therefore produces harmonic voltage distortion, by producing non-sinusoidalContinue reading “Steps to Find the Source of Harmonics”
ADALINE Harmonics Extraction Algorithm applied to a Shunt Active Power Filter based on an Adaptive Fuzzy Hysteresis Current Control and a Fuzzy DC Voltage Controller
Published by Noureddine KHENFAR, Abdelhafid SEMMAH, Mohamed KADEM, Djillali Liabes University of Sidi Bel Abbes, Algeria. Abstract. This paper deals with the use of an adaptive linear (ADALINE) neural network in a harmonic extraction algorithm based on the calculation of instantaneous active and reactive powers. This technique, called “ANN-PQ”, is developed in order to achieveContinue reading “ADALINE Harmonics Extraction Algorithm applied to a Shunt Active Power Filter based on an Adaptive Fuzzy Hysteresis Current Control and a Fuzzy DC Voltage Controller”
Vehicle-to-Grid Technology Employing DC Fast Charging System in Microgrid
Published by Payal jangilwar1, Prof. Balram Yadav2, 1M-tech scholar, Department of Electrical and Electronics Engineering, Scope College of Engineering, Bhopal, 2HOD, Department of Electrical and Electronics Engineering, Scope College of Engineering, Bhopal. Abstract – Electric Vehicles plays an important role in energy storage management in microgrid. This mechanism is managed by grid to vehicle technologyContinue reading “Vehicle-to-Grid Technology Employing DC Fast Charging System in Microgrid”