Memristive Devices In Three-Phase Systems

Published by Piotr ZEGARMISTRZ, Bartłomiej GARDA, AGH University of Science and Technology Abstract. The aim of the research presented in a paper was to provide trustworthy simulation results for symmetrical three-phase systems with memristive load. The memristors in the system are combined with linear resistors in order to limit the current in the element. LinearContinue reading “Memristive Devices In Three-Phase Systems”

Start-up of PM Synchronous Motors

Published by Stanisław GAWRON, Jakub BERNATT, Artur POLAK,Sieć Badawcza Łukasiewicz – Instytut Napędów i Maszyn Elektrycznych KOMEL Abstract. Three variants of starting synchronous motors are presented. In simplest solution, cage winding is placed in rotor, asynchronous start-up is obtained. This method generates large surge currents adversely affecting power grid and motor (impact forces/impact torque areContinue reading “Start-up of PM Synchronous Motors”

Analysis, Simulation and Experimental Validation of High Frequency DC/AC Multilevel Inverter

Published by Alla Eddine TOUBAL MAAMAR, M’hamed HELAIMI, Rachid TALEB, Electrical Engineering Department, Hassiba Benbouali University, LGEER Laboratory, Chlef, Algeria Abstract. In this study, the analysis, simulation and realization of direct current to alternating current multilevel inverter are discussed. Inverter operation with the high-frequency mode is evaluated and tested for the validation of the topology.Continue reading “Analysis, Simulation and Experimental Validation of High Frequency DC/AC Multilevel Inverter”

Monitoring of Electric Arc Furnace Supply Voltage Frequency using Phasor Analysis

Published by Szymon BARCZENTEWICZ, Krzysztof DUDA, Andrzej BIEŃ, AGH University of Science and Technology Abstract. This paper presents the results of measurement experiment conducted in the operating steel plant. Frequency analysis of measured signals revealed an interesting phenomenon, as it happened that after switching off the electric arc furnace, the frequency of the supplying voltageContinue reading “Monitoring of Electric Arc Furnace Supply Voltage Frequency using Phasor Analysis”

Frequency Control in a Power System

Published by Pietro Tumino, EE Power – Technical Articles: Frequency Control in a Power System, October 15, 2020. Learn about the primary, secondary and tertiary frequency control in a power system. An electric power system is characterized by two main important parameters: voltage and frequency.  In order to keep the expected operating conditions and supply energyContinue reading “Frequency Control in a Power System”

The Measurement of Input Power of Power Supply in Network Disturbed by Low Frequency Distortions

Published by Stanisław GALLA, Arkadiusz SZEWCZYK,Gdansk University of Technology Faculty of Electronics, Telecommunications and Informatics Abstract. In the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elementsContinue reading “The Measurement of Input Power of Power Supply in Network Disturbed by Low Frequency Distortions”

Study on Transformer Tank Vibration Characteristics in the Field and its Application

Published by Ji SHENGCHANG, Zhu LINGYU, Li YANMING, State Key Laboratory of Electrical Insulation and Power Equipment, Department of electric engineering, Xi′an Jiaotong University Abstract. Vibration signal analysis method is one of effective methods to monitor the condition of transformer windings and core. In this paper, the multi-channels vibration measurement system is set up andContinue reading “Study on Transformer Tank Vibration Characteristics in the Field and its Application”

EMC for 2 to 150 kHz: A Proposal for Emission and Immunity of Equipment including Power-Line Communication

Published by Anders Larsson and Math Bollen, ELFORSK, Elforsk rapport 09:29, October 2008 Summary The frequency range from 2 to 150 kHz is not sufficiently covered in international standards. The contrast with the frequency range below 2 kHz is striking. There have traditionally been good reasons to emphasize on the lower frequency range, where theContinue reading “EMC for 2 to 150 kHz: A Proposal for Emission and Immunity of Equipment including Power-Line Communication”

A Review on Power Quality Challenges in Renewable Energy Grid Integration

Published by Sonali N. Kulkarni is a Research Scholar, Electronics & Telecommunication Engineering, Rajiv Gandhi Institute of Technology, Versova, Andheri (W), Mumbai, Maharashtra, India. Prashant Shingare is working as Director of Wind Energy, Emerson Network Power India Pvt Ltd, NITCO Business park, Wagle Industrial Estate, Thane (W), Maharashtra, India. Article published in International Journal ofContinue reading “A Review on Power Quality Challenges in Renewable Energy Grid Integration”

Power Quality Measurements in All Voltage Levels of the Utilities up to 150 kHz – Is it Possible?

Published by Roland Buerger (MBS AG), Business Development/R & D, MBS AG, Sulzbach-Laufen (Germany), Email: rbuerger@mbs-ag.com Bernhard Grasel (NEO MESSTECHNIK), Sales Manager, NEO Messtechnik, Zoebern (Austria), Email: bernhard.grasel@neo-messtechnik.com A reliable energy supply has meanwhile become an important location factor for many companies. While power failures and voltage fluctuations were among the most important parameters ofContinue reading “Power Quality Measurements in All Voltage Levels of the Utilities up to 150 kHz – Is it Possible?”