Published by Roland Buerger (MBS AG), Business Development/R & D, MBS AG, Sulzbach-Laufen (Germany), Email: rbuerger@mbs-ag.com Bernhard Grasel (NEO MESSTECHNIK), Sales Manager, NEO Messtechnik, Zoebern (Austria), Email: bernhard.grasel@neo-messtechnik.com A reliable energy supply has meanwhile become an important location factor for many companies. While power failures and voltage fluctuations were among the most important parameters ofContinue reading “Power Quality Measurements in All Voltage Levels of the Utilities up to 150 kHz – Is it Possible?”
Category Archives: Power Quality
Harmonic Response of Distributed Grid Connected Photovoltaic Systems
Published by M. Patsalides is with Dept. of Elec. & Comp. Eng., University of Cyprus, 75 Kallipoleos Avenue, P.O. Box 20537 Nicosia, 1678, Cyprus (e-mail: ee03pm1@ucy.ac.cy). A. Stavrou is with Electricity Authority of Cyprus, Amfipoleos 11, 2025, Nicosia, Cyprus (e-mail: astavrou@eac.com.cy). G. Makrides is with Dept. of Elec. & Comp. Eng., University of Cyprus, 75Continue reading “Harmonic Response of Distributed Grid Connected Photovoltaic Systems”
Power Quality Standards for Utility Wind and Solar Power Plants
Published by David Mueller, E. H. Camm. Abstract Power quality standards exist to guide the interconnection requirements of large wind and solar plants. IEEE guidelines exist for flicker and harmonics, while IEC guidelines exist for the measurement criteria of power quality phenomena and the characterization of wind turbine equipment. There are also some uniform guidelinesContinue reading “Power Quality Standards for Utility Wind and Solar Power Plants”
Bridging the Gap Between Signal and Power
Assessing Power System Quality using Signal Processing Techniques Published by Math H.J. Bollen1, Irene Y.H. Gu2, Surya Santoso3, Mark F. McGranaghan4, Peter A. Crossley5, Moisés V. Ribeiro6, and Paulo F. Ribeiro7 Source: IEEE Signal Magazine, 2009 Signal processing has been used in many different applications, including electric power systems. This is an important category, sinceContinue reading “Bridging the Gap Between Signal and Power”
Part 7: AC Power Distribution Systems & Standards (Overcurrent, Fuse & Circuit Breaker)
Published by Nikola Zlatanov* Complete Overcurrent Device Interest in complete overcurrent device selectivity has increased due to the addition of selectivity requirements to articles 700, 701, and 708 of the National Electrical Code (NFPA70). Many users, both commercial and industrial, use fuses and circuit breakers simultaneously. Traditional Time- Current Curve (TCC) analysis is known toContinue reading “Part 7: AC Power Distribution Systems & Standards (Overcurrent, Fuse & Circuit Breaker)”
Part 6: AC Power Distribution Systems & Standards (Power Quality)
Published by Nikola Zlatanov* Power Quality Terms Technical Overview Introduction Sensitive electronic loads deployed today by users require strict requirements for the quality of power delivered to loads. For electronic equipment, power disturbances are defined in terms of amplitude and duration by the electronic equipment operating envelope. Electronic loads may be damaged and disrupted, withContinue reading “Part 6: AC Power Distribution Systems & Standards (Power Quality)”
Part 5: AC Power Distribution Systems & Standards
Published by Nikola Zlatanov* Medium Voltage Equipment Surge Protection Considerations Transformers If the voltage withstand/BIL rating of the transformer is less than that of the switchgear feeding the transformer, surge protection is recommended at the transformer terminals, in line with established practices. In addition, consideration should be given to using surge arresters and/or surge capacitorsContinue reading “Part 5: AC Power Distribution Systems & Standards”
Part 4: AC Power Distribution Systems & Standards
Published by Nikola Zlatanov* Ground Fault Protection Article 230.95 of NEC requires ground- fault protection of equipment shall be provided for solidly grounded wye electrical services of more than 150 V to ground, but not exceeding 600 V phase-to-phase for each service disconnect rated 1000 A or more. The rating of the service disconnect shallContinue reading “Part 4: AC Power Distribution Systems & Standards”
Part 3: AC Power Distribution Systems & Standards
Published by Nikola Zlatanov* Short-Circuit Currents – General The amount of current available in a short-circuit fault is determined by the capacity of the system voltage sources and the impedances of the system, including the fault. Voltage sources include the power supply (utility or on-site generation) plus all rotating machines connected to the system atContinue reading “Part 3: AC Power Distribution Systems & Standards”
Part 2: AC Power Distribution Systems & Standards
Published by Nikola Zlatanov* Voltage Classifications ANSI and IEEE® standards define various voltage classifications for single-phase and three-phase systems. The terminology used divides voltage classes into: Low voltage Medium voltage High voltage Extra-high voltage Ultra-high voltage Table 1.1-1 presents the nominal system ese classifications. Voltages and Voltage Ranges (From IEEE Standard 141-1993) BIL—Basic Impulse LevelsContinue reading “Part 2: AC Power Distribution Systems & Standards”