Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 4 – Solving and Mitigating Electrical Power Problems. 4.1 Identifying the Root Cause and Assessing Symptoms Power quality technologists employ technical instrumentation. This instrumentation can range from simple digital multi-metering through to sophisticated waveform analysis instruments. True power quality monitoring requires full-timeContinue reading “Solving and Mitigating Electrical Power Problems”
Category Archives: Power Quality
Power Quality Problems
Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 3 – Power Quality Problems. 3.1 How Power Quality Problems Develop Three elements are needed to produce a problematic power line disturbance: A source A coupling channel A receptor If a receptor that is adversely affected by a power line deviation isContinue reading “Power Quality Problems”
Power Quality Measurements and Analysis for Wind Turbines
Published by Mariano Sanz, Member, IEEE, Andrés Llombart, Member, IEEE, Ángel Antonio Bayod and Joaquín Mur, Student Member, IEEE Abstract— A new system for studying power quality (PQ) in wind turbines (WT) has been designed using a data acquisition board (DAQ), LabVIEW programming software and a portable PC. The system has been installed at windContinue reading “Power Quality Measurements and Analysis for Wind Turbines”
Understanding Power Quality Concepts
Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 2 – Understanding Power Quality Concepts. 2.1 The Electrical Distribution System One of the keys to understanding power quality is to understand how electrical power arrives at the socket, and why distribution is such a critical issue. Electrical power is derived fromContinue reading “Understanding Power Quality Concepts”
The Scope of Power Quality
Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 1 – The Scope of Power Quality. 1.1 Definition of Power Quality The Institute of Electrical and Electronic Engineers (IEEE) defines power quality as: “The concept of powering and grounding electronic equipment in a manner that is suitable to the operation ofContinue reading “The Scope of Power Quality”
Power Quality Standards
Published by Pacific Gas and Electric Company (PG&E) IEEE Standard 141-1993, Recommended Practice for Electric Power Distribution for Industrial Plants, aka the Red Book. A thorough analysis of basic electrical-system considerations is presented. Guidance is provided in design, construction, and continuity of an overall system to achieve safety of life and preservation of property; reliability; simplicityContinue reading “Power Quality Standards”
Power Quality Issues in Solar Converters: A Review
Published by J. R. Maglin & R. Ramesh, Department of Electrical and Electronics Engineering, Anna University, Chennai-25, India, E-mail: rramesh@annauniv.edu, Tel: +91-9444217600Published in European Journal of Scientific ResearchISSN 1450-216X Vol.61 No.2 (2011), pp. 321-327http://www.eurojournals.com/ejsr.htm Abstract The main objective of this paper is to identify the problems associated with solar converters in the solar power systemContinue reading “Power Quality Issues in Solar Converters: A Review”
High Neutral-to-Ground Voltages
Published by Electrotek Concepts, Inc., PQSoft Case Study: PQ Investigation at a Battery Facility, Document ID: PQS0401, Date: March 30, 2004. Abstract: An office complex was experiencing continual operational problems with some of their electronic equipment not protected by power conditioning equipment. The equipment would periodically exhibit strange behavior. An infrared heat detector was used toContinue reading “High Neutral-to-Ground Voltages”
Flickering Lights
Published by Electrotek Concepts, Inc., PQSoft Case Study: Flickering Lights Wiring and Grounding Case Study, Document ID: PQS0403, March 30, 2004. Abstract: This case study concerns a residential electrical system. The homeowners were experiencing light flicker when loads were energized and de-energized in their home. INTRODUCTION Residential electric systems are served from single-phase transformers employing aContinue reading “Flickering Lights”
Power Quality Standards, Problems and their Solutions
Published by Vedant S. Samudre, Department of electrical, electronics & power, Jawaharlal, Nehru Engineering College, Aurangabad, Maharashtra, IndiaPublished in International Journal of Engineering Sciences & Research Technology (IJESRT)Website: http://www.ijesrt.comSamudre* et al., 5(12): December, 2016DOI: 10.5281/zenodo.192584 ABSTRACT Power quality is one of the major concerns and emerging issues in the present era. With increasing quantities ofContinue reading “Power Quality Standards, Problems and their Solutions”