Transient Detection using Peak Detectors

Published by Jonny Carlsson, Unipower AB, http://www.unipower.se Background The main problem with transients in the electrical network is that a high voltage potential might break the isolation barrier in for example cables or other equipment in the electrical network. It may also harm semiconductors that are sensitive of high voltage. A transient voltage is byContinue reading “Transient Detection using Peak Detectors”

Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network

Publishd by Ahmed A. Abdullah AL-KARAKCHI1, Enaam ALBANNA2, Alya H. AL-RIFAIE3, Northern Technical University (1,2,3) ORCID: 1. 0000-0003-1151-3015; 2. 0000-0002-3974-0116; 3. 0000-0002-7978-2193 Abstract. Unbalanced network voltage damages utility and end-user equipment. Electrified trains, single-phase distributed generators, and line-toline connected industrial loads can increase voltage imbalances. Using Dynamic Voltage Restorer (DVR) at appropriate places is oneContinue reading “Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network”

Extra High Voltage Transmission Line Lightening Protection using Surge Arrester

Published by Ali HAMOODI, Rasha MOHAMMED, Bashar SALIH, Northern Technical University, Engineering technical college Abstract. The objective of this work was to protect the transmission line (T.L.) from the lightning effect. In the last decades, several methodologies have been employed for the rise of lightning performance on the T.L Lightning with high values of currentContinue reading “Extra High Voltage Transmission Line Lightening Protection using Surge Arrester”

New Technology for PQ Measurements using Auto-Calibration on Capacitive Tap on Inductive Current Transformer

Published by Jonny CARLSSON – Unipower AB, David HOLMBERG – AB Vattenfall, Jan ÖSTLUND – ABB AB Abstract A method of real-time calibrating the voltage signal from the Capacitive Tap on an ABB Current Transformer using Unipowers ‘UP-2210R/ABB Capacitive tap Module’ has produced accurate results of unbalance, harmonics and transients with no limitation in bandwidth.Continue reading “New Technology for PQ Measurements using Auto-Calibration on Capacitive Tap on Inductive Current Transformer”

An Overview of Harmonics in Electrical Systems

Published by Wesco | Anixter, Wesco International. What are harmonics? In an electric power system, a harmonic is a voltage or current at a multiple of the fundamental frequency of the system. Harmonics can best be described as the shape or characteristics of a voltage or current waveform relative to its fundamental frequency. When waveforms deviate from a sinewaveContinue reading “An Overview of Harmonics in Electrical Systems”

Power Quality Improvement in Distributed Generation System under varying Load Conditions using PWM and Hysteresis Controller

Published Vijayshree G1, Sumathi S2, RNSIT, Bangalore,Karnataka,India(1). RNSIT, Bangalore,Karnataka, India(2) Abstract – This paper proposes a power system network modeled using a microgrid, integrated with wind and solar photovoltaic (PV) resources, along with the battery energy storage system (BESS) connected to the three-phase grid feeding the linear and nonlinear load. The simulation is carried outContinue reading “Power Quality Improvement in Distributed Generation System under varying Load Conditions using PWM and Hysteresis Controller”

Upstream Frequency Disturbance

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se We have received questions about disturbances in the grid. Do we have any examples? Here is an interesting example showing how disturbances spread through the network. A major frequency disturbance occured in Scandinavia on December 1, 2005. In this comparison we have compared measuring dataContinue reading “Upstream Frequency Disturbance”

Evaluating Direction of Harmonics – Power Harmonics

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se One important issue is how to trace the source of harmonics. The example below shows harmonic filters connected until 11.00 and there is no voltage distortion as expected. After 11.00 the filters were disconnected due to a fault and voltage harmonics can be seen.Continue reading “Evaluating Direction of Harmonics – Power Harmonics”

Impact of Ambient Temperature on the Failure Intensity of Overhead MV Power Lines

Published by Andrzej Ł. Chojnacki, Kielce University of Technology, Department of Power EngineeringORCID: 0000-0002-9227-7538 Abstract. The article presents the influence of weather conditions, represented by the ambient temperature, for the intensity of the failure of MV overhead power lines. It presents the mechanisms of damaging the equipment by the high and low temperatures. It showsContinue reading “Impact of Ambient Temperature on the Failure Intensity of Overhead MV Power Lines”

Active and Reactive Power Control in a Three-Phase Photovoltaic Inverter

Published by 1.Adnan Majeed Abed1, 2. Afaneen Anwer Alkhazraji2, 3. Shatha S. Abdulla3, University of Technology, Iraq, Baghdad (1), University of Technology, Iraq, Baghdad (2), University of Technology, Iraq, Baghdad (3) ORCID: 1.0000-0002-6558-9552; 2.0000-0003-3995-8307;3. 0000-0001-5493-2485 Abstract. In most nations, grid-connected buildings with solar systems are expanding. Several sites in the system network have high PVContinue reading “Active and Reactive Power Control in a Three-Phase Photovoltaic Inverter”