Impact of Renewable Resources Penetration on Maximum Loading Point and Dynamic Voltage Stability

Published by 1. Benalia Nadia1, 2. Ben Si Ali Nadia1, 3.Zerzouri Nora1, Badji Mokhtar Annaba University B.P 2300 Annaba Algeria. ORCID: 1. 0000-0003-4819-5313; 2. 0000-0001-7248-4823; 3. 0000-0003-1209-4617 Abstract. This paper presents the impact of a grid-connected photovoltaic (PV) generator with a wind turbine on dynamic voltage stability and maximum loading point by considering the PV-windContinue reading “Impact of Renewable Resources Penetration on Maximum Loading Point and Dynamic Voltage Stability”

The Optimisation of the Usage of Electricity from a Wind Turbine in a Household

Published by Wiesław MICZULSKI1, Oliwia PERS2, Uniwersytet Zielonogórski, Instytut Metrologii, Elektroniki i Informatyki (1), ETB Solution GmbH (2) ORCID: 1. 0000-0002-8175-0078; 2. 0000-0002-2962-5261 Abstract. The article presents the concept of an algorithm that optimizes energy management in a household. The algorithm optimizes the usage of the energy from a wind turbine and ensures the greatestContinue reading “The Optimisation of the Usage of Electricity from a Wind Turbine in a Household”

A Statistical Analysis of Wind Speed Probabilistic Distributions for the Wind Power Assessment in Different Regions

Published by 1. Yuly Bay, 2. Nikolay Ruban, 3. Mikhail Andreev, 4. Alexandr Gusev, Tomsk Polytechnic University. ORCID. 1. 0000-0001-9928-408X, 2. 0000-0003-1396-9104, 3. 0000-0002-6420-4374, 4. 0000-0003-0814-2356 Abstract. The penetration of renewable energy sources (RES) into the electricity supply is gaining popularity all over the world, including countries that have large oil and gas reserves, sinceContinue reading “A Statistical Analysis of Wind Speed Probabilistic Distributions for the Wind Power Assessment in Different Regions”

Analysis of the Impact of Wind Turbine Power Characteristics on the Amount of Generated Energy

Published by Damian GŁUCHY1, Grzegorz TRZMIEL2, Poznan University of TechnologyORCID: 1. 0000-0003-2725-2614; 2. 0000-0002-3622-8889 Abstract. In the following article the impact of power characteristics of wind turbines on the total amount of generated power is introduced. The review of scientific literature suggested the need of further analysis of this issue. In order to do so,Continue reading “Analysis of the Impact of Wind Turbine Power Characteristics on the Amount of Generated Energy”

Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation

Published by Hana’ A. Rabab’ah 1, Yaser N. Anagreh2, Al-Ahliyya Amman University (1), Yarmouk University (2) ORCID: 1. 0000-0002-1581-7721; 2. 0000-0002-3826-9262 Abstract. This paper presents an integrated stand-alone wind / Photovoltaic (PV) system enhanced with storage system and the required controllers. The proposed scheme concerned with maximum electrical power extracting from the two renewable energyContinue reading “Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation”

Assessment of Flange Diffuser Structures to Improve the Power Generation of a Diffuser Augmented Wind Turbine

Published by 1. Yiyin KLISTAFANI, 2. A. M. Shiddiq YUNUS, 3. Muhammad ANSHAR, 4. Sri SUWASTI, State Polytechnic of Ujung Pandang, Indonesia (1) ORCID: 1. 0000-0003-3064-9612; 2. 0000-0002-9599-6941; 3. 0000-0001-5687-5023; 4. 0000-0002-7070-9651 Abstract. Wind energy has become the most popular renewable based power plant for the last decades due to its environment benighted and largeContinue reading “Assessment of Flange Diffuser Structures to Improve the Power Generation of a Diffuser Augmented Wind Turbine”

The Analysis of the Wind Generation Impact on the Power System Stability

Published by Michał PIEKARZ, Politechnika Warszawska, Instytut ElektroenergetykiORCID: 0000-0003-1500-2634 Abstract. The article discusses the issues related to the influence of connecting wind turbines on the angular stability of the power system. Current plans for Poland’s energy transition, climate issues, and the most popular types of wind turbines used in the world were discussed. In theContinue reading “The Analysis of the Wind Generation Impact on the Power System Stability”

Wind Power Forecasting Based on Meteorological Data Using Neural Networks

Published by 1. Yuriy SAYENKO1, 2. Ryszard PAWEŁEK2, 3. Vadym LIUBARTSEV1,Pryazovskyi State Technical University (1), Lodz University of Technology, Institute of Electrical Power Engineering (2) ORCID. 1. 0000-0001-9729-4700, 2. 0000-0002-1023-8210, 3. 0000-0003-1243-9101 Abstract. The growing share of renewable energy sources in the structure of energy systems causes many problems related to the correct operation ofContinue reading “Wind Power Forecasting Based on Meteorological Data Using Neural Networks”

Wind Farms in the Process of Voltage Regulation in the Power System

Published by Ľubomír BEŇA1, Paweł KUT2,Rzeszow University of Technology, Faculty of Electrical and Computer Engineering (1)Rzeszow University of Technology, Faculty of Civil and Environmental Engineering and Architecture (2) Abstract. The large number of wind farms in the power system makes it possible to use them in the process of voltage regulation in the nodes toContinue reading “Wind Farms in the Process of Voltage Regulation in the Power System”

Analysis of the Impact of a Wind Farm on the Quality of Electricity in the Distribution Grid

Published by Joanna KOZIEŁ, Grzegorz KOMARZYNIEC, Andrzej WAC-WŁODARCZYK, Ryszard GOLEMAN, Department of Electrical Engineering and Electrotechnologies, Lublin University of Technology Abstract. The article presents the characteristics of the net power of a wind farm as a function of wind speed, and lists the factors determining the selection of a wind farm. Classification of large windContinue reading “Analysis of the Impact of a Wind Farm on the Quality of Electricity in the Distribution Grid”