Published by Shuhei Kato, Miao-miao Cheng, Hideo Sumitani and Ryuichi Shimada,Integrated Research Institute, Tokyo Institute of Technology, Japan SUMMARY Flywheel energy storage systems can be used as an uninterrupted power supply system because they are environmentally friendly and have high durability. The use of a simple voltage sag compensator with a low-speed heavy flywheel andContinue reading “Flywheel Size Design Considerations and Experimental Verification Using a 50-kW System for Voltage Sag Compensator with Flywheel Induction Motor”
Tag Archives: Voltage Sags/Surges
Power Quality Problems
Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 3 – Power Quality Problems. 3.1 How Power Quality Problems Develop Three elements are needed to produce a problematic power line disturbance: A source A coupling channel A receptor If a receptor that is adversely affected by a power line deviation isContinue reading “Power Quality Problems”
General Reference Common Power Quality Problems and Solutions
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference Common Power Quality Problems and Solutions, Document ID: PQS0315, Date: July 18, 2003. Abstract: Power quality is a frequently used term that means different things to different people. Common power quality problems include all of the issues that arise from the incompatibility between a utility’s powerContinue reading “General Reference Common Power Quality Problems and Solutions”
Wind Energy Conversion System from Electrical Perspective — A Survey
Published by Hyong Sik Kim, Dylan Dah-Chuan Lu, School of Electrical and Information Engineering, University of Sydney, Sydney, Australia. Email: hkim4210@uni.sydney.edu.au Smart Grid and Renewable Energy, 2010, 1, 119-131 doi:10.4236/sgre.2010.13017 Published Online November 2010 (http://www.SciRP.org/journal/sgre). Received October 20th, 2010; revised November 14th, 2010; accepted November 20th, 2010. ABSTRACT This paper focuses on the wind energyContinue reading “Wind Energy Conversion System from Electrical Perspective — A Survey”
Historical Perspective of Utility PQ Standards Year 2000 timeframe
Published by Terry Chandler, Director of Engineering, Power Quality Thailand Ltd. & Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th
Sags and Swells
Published by Richard P. Bingham, Manager of Technology and Products, Dranetz – BMI, 1000 New Durham Road, Edison, NJ 08818-4019, Phone 732-248-4393, Fax 732-287-8320. February 16, 1998 ABSTRACT Sags and swells are the most common types of power quality disturbances. Millions of dollars are lost in productivity each year in the United States due toContinue reading “Sags and Swells”
Some Comments on Power Acceptability Curves
Published by G. Heydt , Arizona State University Tempe, Arizona USA R. Thallam, Salt River Project Phoenix, Arizona USA M. Albu, Universitatea Politehnica Bucureşti Bucharest, Romania CARIBBEAN COLLOQUIUM ON POWER QUALITY (CCPQ), JUNE 2003 Abstract Power acceptability curves, also known as voltage vulnerability or sensitivity curves, have been used for over 30 years to characterizeContinue reading “Some Comments on Power Acceptability Curves”
A Technical Investigation of Voltage Sag
Published by 1Vima P. Mali, 2R. L. Chakrasali, 1K. S. Aprameya, 1Electrical and Electronics Engineering Research Centre, University B.D.T. College of Engineering, Davanagere, India. 2Department of Electrical and Electronics Engineering, SDM College of Engineering and Technology, Dharwad, India. Research Paper Source: American Journal of Engineering Research (AJER) 2015. American Journal of Engineering Research (AJER) e-ISSN:Continue reading “A Technical Investigation of Voltage Sag”
Proposal for Defining Voltage Dip-Related Responsibility Sharing at a Point of Connection
Published by S. Bhattacharyya1, S. Cobben2, & W. Kling, Electrical Engineering Department, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.E-mails: s.bhattacharyya@tue.nl1; sharmirb@yahoo.com2 Published in IET Generation, Transmission & Distribution. Received on 24th May 2011 – Revised on 29th February 2012, doi: 10.1049/iet-gtd.2011.0801 Abstract Modern customers use many electronics devices that are quite sensitive toContinue reading “Proposal for Defining Voltage Dip-Related Responsibility Sharing at a Point of Connection”
Survey on Voltage Improvement
Published by Raghawendra Sharan Mishra, Student, Department of Instrumentation & Control, Maharana Pratap College of Technology, Gwalior, India. Mr. Prasant Kumar, Assistant Professor, Department of Electrical Engineering, Maharana Pratap College of Technology, Gwalior, India. IJSRD – International Journal for Scientific Research & Development | Vol. 5, Issue 09, 2017 | ISSN (online): 2321-0613 Abstract PowerContinue reading “Survey on Voltage Improvement”