High Performance of Multilevel Inverter Reduced Switches for a Photovoltaic System

Published by Laith A. Mohammed1, Taha A. Hussein2, Ahmed T. Sadoon3, Northern Technical University, Engineering Technical College of Mosul, Mosul, Iraq.ORCID: 10000-0002-2882-2845; 2. 0000-0001-9516-6860; 3. 0000-0002-8440-6061 Abstract. In this paper, optimum switching angles are chosen from slime moiled algorithm (SMA), Artificial Bee Colony (ABC), Genetic algorithms (GA), Whale optimization algorithm (WOA), and Gray wolf algorithmContinue reading “High Performance of Multilevel Inverter Reduced Switches for a Photovoltaic System”

Possibilities of Using Blockchain Technology in the Area of Electricity Trade Settlements

Published by Anna ZIELIŃSKA AGH University of Science and Technology, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering. ORCID. 0000-0002-2889-1488 Abstract: The article describes the advantages and possibilities of using blockchain in various areas and sectors of the economy related to electricity trade and trading. The aim of the article is to presentContinue reading “Possibilities of Using Blockchain Technology in the Area of Electricity Trade Settlements”

Case Study for Obtaining Power Quality Grid-Code Compliance

Published by Dirk A. J. van der Bank, and Kyle Lass, Energize, July 2018 The practical implications of obtaining power quality (PQ) grid-code compliance for category C photovoltaic (PV) renewable power plants (RPP) are described in this article. Successful harmonic mitigation was implemented via means of the installation of active harmonic filters (AHF) at lowContinue reading “Case Study for Obtaining Power Quality Grid-Code Compliance”

The Analysis of the Wind Generation Impact on the Power System Stability

Published by Michał PIEKARZ, Politechnika Warszawska, Instytut ElektroenergetykiORCID: 0000-0003-1500-2634 Abstract. The article discusses the issues related to the influence of connecting wind turbines on the angular stability of the power system. Current plans for Poland’s energy transition, climate issues, and the most popular types of wind turbines used in the world were discussed. In theContinue reading “The Analysis of the Wind Generation Impact on the Power System Stability”

Effect of Solar Radiation on Power Losses and Capacity of Insulated and Non-Insulated Wires of Overhead Power Lines

Published by Stanilav S. Girshin1, Igor A. Sorokin2, Aleksandr N. Smerdin3, Aleksandr AY. Bigun1, Elena V. Petrova1, Vladislav M. Trotsenko1, Vladimir N. Goryunov1, George S. Smorodin1, Omsk State Technical Univercity, Omsk, Russia (1)Public Join Stock «Interregional Distribution Grid Company of Siberia» (2)Omsk State Transport University, Omsk, Russian (3) Abstract. The influence of solar radiation onContinue reading “Effect of Solar Radiation on Power Losses and Capacity of Insulated and Non-Insulated Wires of Overhead Power Lines”

Mathematical Modelling of Battery Energy Storage Systems in the Additional Service Market of the United Electric Power System of Ukraine

Published by 1. Petro LEZHNIUK, 2. Yulia MALOGULKO, 3. Ihor PROKOPENKO, Vinnitsa National Technical University, Ukraine. ORCID. 1. 0000-0003-0338-2131, 2. 0000-0002-6637-7391, 3. 0000-0001-6050-9413 Abstract. The paper considers the possibility of providing services from the automatic reserve of frequency recovery and the provision of balancing services. Determined the relationship between the price indices of additional serviceContinue reading “Mathematical Modelling of Battery Energy Storage Systems in the Additional Service Market of the United Electric Power System of Ukraine”

Distributed Photovoltaic Integration as Complementary Energy: Consideration of Solutions for Power Loss and Load Demand Growth Problems

Published by Salama MANJANG1, Yuli Asmi RAHMAN2,University of Hasanuddin (1), University of Tadulako (2), Indonesia Abstract. The purpose of this study is to optimize the location and capacity of PV in the feeder distribution system 20 kV of Central Sulawesi, Indonesia. The proposed method uses the optimization method of development from the genetic algorithm, namelyContinue reading “Distributed Photovoltaic Integration as Complementary Energy: Consideration of Solutions for Power Loss and Load Demand Growth Problems”

Wind Power Forecasting Based on Meteorological Data Using Neural Networks

Published by 1. Yuriy SAYENKO1, 2. Ryszard PAWEŁEK2, 3. Vadym LIUBARTSEV1,Pryazovskyi State Technical University (1), Lodz University of Technology, Institute of Electrical Power Engineering (2) ORCID. 1. 0000-0001-9729-4700, 2. 0000-0002-1023-8210, 3. 0000-0003-1243-9101 Abstract. The growing share of renewable energy sources in the structure of energy systems causes many problems related to the correct operation ofContinue reading “Wind Power Forecasting Based on Meteorological Data Using Neural Networks”

Methods of Calculating Solar Insolation for the Assessment of Energy Efficiency of Solar Power Plants

Published by Sergey CHIZHMA, Artyom ZAKHAROV, Immanuel Kant Baltic Federal University (Kaliningrad, Russia) Abstract. The authors explore a number of methods of calculating insolation on a tilted arbitrarily oriented surface and choose the most efficient one for conducting the performance and efficiency analysis of solar power plants. The validity of the method is tested usingContinue reading “Methods of Calculating Solar Insolation for the Assessment of Energy Efficiency of Solar Power Plants”

Fuzzy Logic-Based Control Strategy for Hourly Power Dispatch of Grid-Connected Photovoltaic with Hybrid Energy Storage

Published by 1. Mohd Afifi JUSOH, 2. Muhamad Zalani DAUD, 3. Mohd Zamri IBRAHIM, Faculty of Ocean Engineering Technology and Informatics, Universiti Malaysia Terengganu, 21030 Kuala Nerus, Terengganu MalaysiaORCID: 1. 0000-0001-9929-4640; 2. 0000-0003-3003-3068; 3. 0000-0002-9439-8552 Abstract. The inconsistency of solar irradiance and temperature have led to unpredictable output power fluctuation of photovoltaic (PV) system. ThisContinue reading “Fuzzy Logic-Based Control Strategy for Hourly Power Dispatch of Grid-Connected Photovoltaic with Hybrid Energy Storage”