Fluke 43B PQ Analyzer – Basic Measurements

Applications Guide, April 2001 Published by Fluke Corporation Introduction This section provides easy-to-do measurements which you can perform almost anywhere. Begin with these examples to get started with the Fluke 43B. Note: It is a good idea to reset the Fluke 43B before you start a new application. This way, you always start from theContinue reading “Fluke 43B PQ Analyzer – Basic Measurements”

Bridging the Gap Between Signal and Power

Assessing Power System Quality using Signal Processing Techniques Published by Math H.J. Bollen1, Irene Y.H. Gu2, Surya Santoso3, Mark F. McGranaghan4, Peter A. Crossley5, Moisés V. Ribeiro6, and Paulo F. Ribeiro7 Source: IEEE Signal Magazine, 2009 Signal processing has been used in many different applications, including electric power systems. This is an important category, sinceContinue reading “Bridging the Gap Between Signal and Power”

Defining Interharmonics

White Paper, April 2013 Contributed by Chris Mullins, VP of Engineering and Operations, Power Monitors, Inc. Email: cmullins@powermonitors.comWebsite: http://www.powermonitors.comTel: 800.296.4120 ABSTRACT Interharmonics are frequency components at noninteger harmonics of the line frequency. The proliferation of large DC-converter variable speed drives and wind/solar inverter generation has led to an increase in interharmonic levels. Troubleshooting the resultingContinue reading “Defining Interharmonics”

Part 6: AC Power Distribution Systems & Standards (Power Quality)

Published by Nikola Zlatanov* Power Quality Terms Technical Overview Introduction Sensitive electronic loads deployed today by users require strict requirements for the quality of power delivered to loads. For electronic equipment, power disturbances are defined in terms of amplitude and duration by the electronic equipment operating envelope. Electronic loads may be damaged and disrupted, withContinue reading “Part 6: AC Power Distribution Systems & Standards (Power Quality)”

Part 1: AC Power Distribution Systems & Standards

Published by Nikola Zlatanov Mr. Nikola Zlatanov spent over 20 years working in the Capital Semiconductor Equipment Industry. His work at Gasonics, Novellus, Lam and KLA-Tencor involved progressing electrical engineering and management roles in disruptive technologies. Nikola received his Undergraduate degree in Electrical Engineering and Computer Systems from Technical University, Sofia, Bulgaria and completed aContinue reading “Part 1: AC Power Distribution Systems & Standards”

Measurement Practices for Reliability and Power Quality: Appendix D and E

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Measurement Practices for Reliability and Power Quality: Appendix D and E”

Part 9 Markets and the Provision of Basic Service

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 9 Markets and the Provision of Basic Service”

Part 8 Standardizing Reliability and Power Quality Metrics

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 8 Standardizing Reliability and Power Quality Metrics”

Part 7 Valuing Reliability

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 7 Valuing Reliability”

Part 6 Pitfalls in Methods for Reliability Index Calculation

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 6 Pitfalls in Methods for Reliability Index Calculation”