Published by Vedant S. Samudre, Department of electrical, electronics & power, Jawaharlal, Nehru Engineering College, Aurangabad, Maharashtra, IndiaPublished in International Journal of Engineering Sciences & Research Technology (IJESRT)Website: http://www.ijesrt.comSamudre* et al., 5(12): December, 2016DOI: 10.5281/zenodo.192584 ABSTRACT Power quality is one of the major concerns and emerging issues in the present era. With increasing quantities ofContinue reading “Power Quality Standards, Problems and their Solutions”
Tag Archives: Power Quality
General Reference – Performing Power Quality Audits
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Performing Power Quality Audits, Document ID: PQS0306, Date: February 4, 2003. Abstract: Power quality investigations often require monitoring to identify the exact problem and then to verify the solutions that are implemented. Before embarking on extensive monitoring programs, it is important to develop an understandingContinue reading “General Reference – Performing Power Quality Audits”
A Power Quality and Load Analysis of a Cryptocurrency Mine
Published by Keaton A. Wheeler, Anthony W. Bowers, Charlie H. Wong, Jonathan Y. Palmer and Xue Wang, Primary Engineering and Construction, Saskatoon/Kelowna, Canada{kwheeler, abowers, cwong, jpalmer & swang}@primaryeng.comPublished in: 2018 IEEE Electrical Power and Energy Conference (EPEC)Date of Conference: 10-11 Oct. 2018DOI: 10.1109/EPEC.2018.8598358 Abstract— This paper conducts a load and power quality analysis on aContinue reading “A Power Quality and Load Analysis of a Cryptocurrency Mine”
General Reference – Power Quality Assessment Procedure
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Power Quality Assessment Procedure, Document ID: PQS0608, Date: July 1, 2006. Abstract: Power quality is a frequently used term that means different things to different people. Common power quality problems include all of the issues that arise from the incompatibility between a utility’s power andContinue reading “General Reference – Power Quality Assessment Procedure”
Power Quality and Electrical Arc Furnaces
Published by Horia Andrei1, Costin Cepisca2 and Sorin Grigorescu21Valahia University of Targoviste, 2Politehnica University of Bucharest, Romania 1.Introduction The chapter covers general issues related to power quality in Electric Arc Furnaces. The use of electric arc furnaces (EAF) for steelmaking has grown dramatically in the last decade. Of the steel made today 36% is producedContinue reading “Power Quality and Electrical Arc Furnaces”
General Reference Common Power Quality Problems and Solutions
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference Common Power Quality Problems and Solutions, Document ID: PQS0315, Date: July 18, 2003. Abstract: Power quality is a frequently used term that means different things to different people. Common power quality problems include all of the issues that arise from the incompatibility between a utility’s powerContinue reading “General Reference Common Power Quality Problems and Solutions”
Why is Good Power Quality Necessary?
Published by Merus Power Plc., October 13, 2016 Power quality is commonly defined as the power grid’s ability to supply a clean and stable power flow as a constantly available power supply. The power flow should have a pure sinusoidal wave form and it should remain within specified voltage and frequency tolerances. Why is goodContinue reading “Why is Good Power Quality Necessary?”
General Reference – Power Quality Glossary
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Power Quality Glossary, Document ID: PQS0305, Date: January 27, 2003. Abstract: The document provides a glossary of terms related to power quality analysis and measurements. POWER QUALITY GLOSSARY Glossary Active Filter:A power electronics-based device configured with controls to provide cancellation of harmonic current components createdContinue reading “General Reference – Power Quality Glossary”
What is your PQ IQ?
Affinity Energy – Infographic: Understanding the Impacts of Power Quality. Understanding power quality issues $15 billion is the annual cost of power quality issues. $130,000 are the potential costs for downtime in lost revenue for facilities. For mission critical facilities, that translates to $14,000 to $6.5 million every hour. It takes 17 hours for plants toContinue reading “What is your PQ IQ?”
Power Quality and Harmonics
Published by Wayne Walcott, MTE Application engineering Manager, August , 2015. website: mtecorp.com