Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations

Published by 1. Ilham Bouaissi1, 2. Ali Rezig1, 3. Said Touati2, L2EI Laboratory, University Mohammed Seddik Benyahia, Ouled Aissa. Bp 98, Jijel, 18000, Algeria (1). Nuclear research center, Birine, Ain Oussera. Bp 180, Djelfa, 17200 Algeria (2) ORCID: 1. 0000-0001-5981-6918 Abstract. One of the problems with induction motors, say the experts, is voltage. Insulation deteriorationContinue reading “Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations”

Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation

Published by 1. Nuri Berisha, 2. Bahri Prebreza*, 3. Petrit Emini, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0001-8615-637X; 2. 0000-0003-1950-026X; 3. 0000-0002-2833-9001 Abstract. Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells,Continue reading “Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation”

Frequency Resolution Improvements in Induction Motor Fault Diagnosis : Experimental Validation

Published by Ameur Fethi AIMER1, Ahmed Hamida BOUDINAR2, Mohamed Amine KHODJA2, Azeddine BENDIABDELLAH2, University of Saida. Algeria (1), University of Sciences and Technology of Oran. Algeria (2) ORCID: 1. 0000-0003-4933-109X Abstract. Induction machines are enjoying growing interest mainly due to their robustness, their weight to power ratio and their manufacturing cost. However, several faults affectContinue reading “Frequency Resolution Improvements in Induction Motor Fault Diagnosis : Experimental Validation”

Direct-Phase Variable Modelling and Analysis of Five-Phase Synchronous Reluctance Motor for Direct-on-Line Starting

Published by Gideon UMOH1, Chinedu OBE2, Cosmas OGBUKA2, George EKPO3, Emeka OBE2, Department of Electrical Engineering, Maritime Academy of Nigeria, Oron, Akwa-Ibom State, Nigeria(1),Department of Electrical Engineering, University of Nigeria, Nsukka, Enugu State, Nigeria(2)Department of Electrical and Electronic Engineering, Akwa Ibom State Polytechnic, Ikot Osurua, Nigeria(3) Abstract. The direct-phase variable (DPV) model of a five-phaseContinue reading “Direct-Phase Variable Modelling and Analysis of Five-Phase Synchronous Reluctance Motor for Direct-on-Line Starting”

Inter-Turns Short Circuits in Stator Winding of Squirrel-Cage Induction Motor

Published by Maciej ANTAL, Wrocław University of Science and Technology, Department of Electrical Machines, Drives and Measurements Abstract. A physical model of a squirrel-cage induction drive, allowing to stimulate coil short circuits in the front part of the motor, was used to investigate the phenomena accompanying short circuits. Assuming that a short circuit occurs duringContinue reading “Inter-Turns Short Circuits in Stator Winding of Squirrel-Cage Induction Motor”

Converter-Fed Electric Vehicle (Car) Drives – A Critical Review

Published by Konrad DĄBAŁA1, Marian P. KAZMIERKOWSKI1,2,The Łukasiewicz Research Network – Electrotechnical Institute, Warsaw (1)Warsaw University of Technology, Faculty Electrical Engineering (2) Abstract In this paper the basic requirements and current developments of converter-fed drives for electric vehicles, particularly for electric cars, are reviewed and compared. The basic parts of the powertrain have been presentedContinue reading “Converter-Fed Electric Vehicle (Car) Drives – A Critical Review”

Enclosure-Less Six-Phase Induction Motor

Published by Maciej GWOZDZIEWICZ1, Piotr KISIELEWSKI2, Wroclaw University of Science and Technology (1), KISIELEWSKI Sp. z o.o. (2) Abstract. The papers deals with six-phase 2 kW 2-pole induction motor without enclosure. The motor is made of laser-cut construction steel , electrical steel and copper sheets. Shaft, two flange cartridge bearing units are machined by theContinue reading “Enclosure-Less Six-Phase Induction Motor”

IM Drive System Supplied from PV Panels with Energy Storage – Experimental Setup

Published by Wojciech MATELSKI1, Electrotechnical Institute, Warsaw Abstract. The article describes a practical implementation of the induction motor (IM) drive system powered from photovoltaic (PV) panels. The system incorporates an energy storage device, in form of a supercapacitor bank, and enables an AC grid connection. Two system concepts are considered, thus a discussion about theContinue reading “IM Drive System Supplied from PV Panels with Energy Storage – Experimental Setup”