2 Week Energy Survey

Published by Dranetz Technologies, Inc., Case Study Willows Swim Club is a private, member-owned swimming and recreational facility located in central New Jersey. The swim club provides kitchen space to a local restaurant to operate a food concession. Being offered as a service to its membership, there is presently no charge for rent or utilities. However, givenContinue reading “2 Week Energy Survey”

Comparison of Compact Fluorescent to Incandescent Bulbs

Published by Dranetz Technologies, Inc., Case Study With the proliferation of Compact Florescent (CF) lighting, we thought it would be interesting to do a side by side comparison to an incandescent bulb using our new Energy Platform EP1. Not only is it a great demonstration of the capabilities of the EP1 but it’s also an opportunity toContinue reading “Comparison of Compact Fluorescent to Incandescent Bulbs”

Bank’s High 9’s Infrastructure Saved from Disaster

Published by Dranetz – BMI Case Studies The power system for this major NYC bank providing nationwide credit card and other financial transactions appeared to be performing satisfactorily. Fortunately, the proactive monitoring approach employed in this facility identified a power quality trend that could have caused a catastrophic failure. Non-symmetrical waveforms rich with even orderContinue reading “Bank’s High 9’s Infrastructure Saved from Disaster”

24/7 Customer Service Center

Published by Dranetz – BMI Case Studies In 2000, DHL Airways opened a new 24/7 customer service center to support its US customer base. To maximize uptime and ensure high reliability, a redundant UPS system was installed, protecting both the supply and the facility loads. Integral to the facility design was the Signature System powerContinue reading “24/7 Customer Service Center”

Loose Bus Bar Bolts Cause Sags

Published by Dranetz – BMI Case Studies An administration building in a government complex in New Jersey had a transformer with a 4KV primary, 120/208V wye, 800A secondary. The buss duct ran up to a second-floor panel, which supplied an office area. Computer misoperations and lights flickering were occurring randomly for nearly two years. EmergencyContinue reading “Loose Bus Bar Bolts Cause Sags”

Textile Industry Evaluation

Published by Dranetz – BMI Case Studies Despite their differences, continuous-process industries share underlying characteristics: they maintain continuous operations in facilities that represent substantial start-up costs and time but can be interrupted or disrupted by seemingly minor fluctuations in power quality. If the product stream is disrupted, lost productivity and lost product can create aContinue reading “Textile Industry Evaluation”

Thumping Sounds in the Closet

Published by Dranetz – BMI Case Studies Elevator control panels for the lower zone mid-rise elevators were on the nineteenth floor of a forty-story office building in a large midwestern city. It was fed with 480V transformer on the same floor, with the feeders to the controls rated at 800A. Excessive noise and vibration ofContinue reading “Thumping Sounds in the Closet”

The Case of the Missing Contact

Published by Dranetz – BMI Case Studies Executive SummaryDefiance Metal Products Company contracted with Electrotek Concepts to perform field measurements of their welding operations, and to make recommendations for remediation of Power Quality problems at the facility. The customer has been experiencing both major and minor electrical problems. The minor problems include occasional observable flickerContinue reading “The Case of the Missing Contact”

Computer on Shared Branch Circuit

Published by Dranetz – BMI Case Studies Engineering laboratory adjacent to offices. A computer system used by laboratory personnel exhibited intermittent failures and data errors. Typically, these would start around 10 a.m. On some days there were no failures. A power monitor was installed at the panelboard serving the computer system. The monitor was connected,Continue reading “Computer on Shared Branch Circuit”

Manufacturing Process Unexpectedly Halted

Published by Dranetz – BMI Case Studies This medium-sized manufacturing facility, located in an industrial park that experienced an unexplained shutdown of several adjustable speed drives (ASDs) , wreaking havoc on key process equipment. Each day, at approximately 6 am, the utility-owned PF capacitor kicks on to improve the voltage of inductive loads prevalent inContinue reading “Manufacturing Process Unexpectedly Halted”