Increasing the Impulse Electrical Strength of Winding Insulationof High-Voltage Transformers

Published by Elbrus AHMEDOV1, Nadir ALİYEV2, Seymur SADIQOV3,Azerbaijan State Oil and Industry University (1, 2) ORCID: 1. 0000-0003-3348-7946; 2. 0009-0001-3165-1493 Abstract. The present article delves into strategies aimed at augmenting the impulse electrical strength of the insulation in high-voltage transformer windings. The research focal point centers on an authentically produced autotransformer boasting a 330 kVContinue reading “Increasing the Impulse Electrical Strength of Winding Insulationof High-Voltage Transformers”

Diagnostics of Electric Drive Electric Vehicle with Valve Motor

Published by 1. Yurii Borodenko 1, 2. Shchasiana Arhun 1,2, 3. Andrii Hnatov 1, 4. Nadezhda Kunicina 2, Martins Bisenieks 2, 6. Vasiliy Migal 3, 7. Hanna Hnatova 1,2 , Department of Vehicle Electronics, Kharkiv National Automobile and Highway University, Khrakiv, Ukraine; docentmaster@gmail.com (Yu.B.); shasyana@gmail.com (Shch.A); kalifus76@gmail.com (A.H.); annagnatova22@gmail.com (H.H.) (1) Riga Technical University, FacultyContinue reading “Diagnostics of Electric Drive Electric Vehicle with Valve Motor”

Generation of High-Voltage Solitons in a Non-Linear Transmission Line

Published by 1. Andrzej FARYŃSKI1, 2. Zbigniew ZIÓŁKOWSKI1, 3. Przemysław SUL2, Air Force Institute of Technology (AFIT) (1), Warsaw University of Technology (2)ORCID: 1. 000-0008-1232-2747; 2. 000-0002-7713-0271; 3. 0000-0002-4327-9334 Abstract. The article describes research, the main aim of which was to present the method of generating high-voltage impulses – solitons using a non-linear NLTL transmissionContinue reading “Generation of High-Voltage Solitons in a Non-Linear Transmission Line”

Estimation of Capacitors Stray Inductance by the Analysis of Overdamped Discharge Current Curves

Published by Ivan KOSTIUKOV, National Technical University “Kharkiv Polytechnic Institute”, Department of Electrical Insulation and Cable Engineering, Ukraine Abstract. This paper gives a description of measurement method which can be used in practice of carrying out measurement of stray inductance of tested capacitive object with the unknown value of electrical capacitance. Stray inductance is determinedContinue reading “Estimation of Capacitors Stray Inductance by the Analysis of Overdamped Discharge Current Curves”

Hybrid Energy Storage System in Hybrid Vehicles: Design of Energy Management Strategy and Comparative Analysis

Published by Piotr WOŹNIAK, Politechnika Łódzka, Instytut Systemów Inżynierii Elektrycznej Abstract. This article presents simulation tests showing the benefits of using an additional energy storage device in the form of a supercapacitor in a hybrid car. An original power flow control system was proposed. The main emphasis was placed on determining the driving characteristics, emissionsContinue reading “Hybrid Energy Storage System in Hybrid Vehicles: Design of Energy Management Strategy and Comparative Analysis”

The New Design of the Vacuum Circuit Breaker Mounted on the Roof of Electric Traction Units

Published by Piotr BORKOWSKI1, Łukasz NOWAK1, Stanisław SZYMAŃSKI2,Department of Electrical Apparatus of the Technical University of Lodz(1), Factory of Electrical Apparatus Woltan(2) Abstract. This article presents the research on new design of a vacuum breaker type DCU-800M mounted on the roof of Electric Traction Units. The impact of one circuit breaker on another one wasContinue reading “The New Design of the Vacuum Circuit Breaker Mounted on the Roof of Electric Traction Units”

Usability Evaluation of PEM Fuel Cell and Supercapacitors Application in the Emergency Power Backup System

Published by Marek MALINOWSKI, Jacek CHMIELOWIEC, Grzegorz PAŚCIAK, Tymoteusz ŚWIEBODA, Electrotechnical Institute, Division of Electrotechnology and Materials Science Abstract. Evaluation of FC/SC-based UPS has been done in terms of energy containers usability in the power emergency generation system. The Uninterruptible Power Supply delivers electric support for connected loads basing on hydrogen energy direct conversion intoContinue reading “Usability Evaluation of PEM Fuel Cell and Supercapacitors Application in the Emergency Power Backup System”

Study on a New Method for Overvoltage Measurement using CVT

Published by Si WENRONG, Jin HENG, Huang HUA, Fu CHENZHAO, East China Electric Power Test & Research Institute Company Limited, Shanghai, China Abstract. This paper introduces a new method for overvoltage measurements in 500kV power system using capacitor voltage transformer (CVT). It is realized with a voltage sensor installed within CVT as the low-voltage capacitorContinue reading “Study on a New Method for Overvoltage Measurement using CVT”

The Trouble With Capacitors Part 2

Published by R. Fehr, P.E., Engineering Consultant, Jan 1, 2004 Here’s how to reduce the effect of capacitor switching on your power system Last month’s article discussed exactly what happens when electric utilities switch shunt capacitors: power system components are exposed to transient voltages and currents produced by energizing and de-energizing these devices. Those transientsContinue reading “The Trouble With Capacitors Part 2”

The Trouble With Capacitors Part 1

Published by R. Fehr, P.E., Engineering Consultant, Dec 1, 2003 Although shunt capacitors offer several advantages at all voltage levels, those advantages come at a price. Not only must you purchase, install, and maintain capacitor equipment, you must be able to switch it in and out of service to get the most from the system.Continue reading “The Trouble With Capacitors Part 1”