Published by Samhar Saeed Shukir, Electrical Department, Technical Institute- Kut, Middle Technical University, Baghdad, Iraq. Corresponding Author: samharalwandi@gmail.com ABSTRACT Solar power has numerous benefits, it is a clean and renewable energy resource that can help us to reduce carbon emissions from fossil fuel use and mitigate climate change. However, solar energy production is limited toContinue reading “Solar Energy Batteries – A Critical Review”
Category Archives: Renewable Generation
Effect of a Wind Generator on the Optimal Location of FACTS
Published by Messaoud ZOBEIDI*1, Fatiha LAKDJA2, Yamina Ahlem GHERBI3, Fatima Zohra GHERBI1 ,Department of electrical Engineering, laboratory of ICEPS, Djillali Liabes Universiy, Sidi-Bel-Abbes, Algeria(1), Department of electrical Engineering, laboratory of ICEPS ,Saida Universiy,Saida , Algeria (2), Department of electrical Engineering, USTO-MB Oran , Durable Development of Electric power laboratory, Algeria(3) Abstract. The development has contributedContinue reading “Effect of a Wind Generator on the Optimal Location of FACTS”
Fluid Interaction in a Complex Terrain Wind Farm
Published by Bukurije HOXHA1, Risto V.FILKOSKI2 , University of Prishtina “Hasan Prishtina” (1), Ss. Cyril and Methodius University, Skopje (2)ORCID: 1. 0000-0002-8890-2054; 2. 0000-0002-3743-318X Abstract. Optimisation of the placement of wind turbines in a farm is an important stage in wind farm construction. Koznica, a mountainous terrain available for wind farms, is considered in theContinue reading “Fluid Interaction in a Complex Terrain Wind Farm”
Effect of Grid-Connected Photovoltaic Systems on Static and Dynamic Voltage Stability with Analysis Techniques – A Review
Published by ZETTY ADIBAH KAMARUZZAMAN1, AZAH MOHAMED2, HUSSAIN SHAREEF3,Universiti Kebangsaan Malaysia Abstract. This paper presents an overview on the effect of grid-connected photovoltaic (PV) system on static and dynamic voltage stability and discusses the analysis techniques used to quantify the effect. A review on the published works showed that the PV system design, PV parametersContinue reading “Effect of Grid-Connected Photovoltaic Systems on Static and Dynamic Voltage Stability with Analysis Techniques – A Review”
Application of Genetic Algorithm for Optimal Placement of Wind Generators in the MV Power Grid
Published by Ryszard SZCZEBIOT1, Sławomir CIEŚLIK2, State College of Computer Science and Business Administration in Łomża (1)University of Technology and Life Sciences, Bydgoszcz (2) Abstract. The paper presents a modelling method of optimal connection of wind generators to a medium voltage (MV) power grid taking into account minimum active power losses. A genetic algorithm wasContinue reading “Application of Genetic Algorithm for Optimal Placement of Wind Generators in the MV Power Grid”
Some Aspects of the Growing Penetration of Wind Energy in the Polish Power System
Published by Tadeusz SKOCZKOWSKI1, Maksymilian KOCHAŃSKI1,2, Warsaw University of Technology (1), Research and Innovation Centre Pro-Akademia (2) Abstract. According to the Energy Policy of Poland by 2030 the national power system will have to acquire 12 times more electricity from wind energy than in 2011. This challenging policy goal entails a number of significant consequences.Continue reading “Some Aspects of the Growing Penetration of Wind Energy in the Polish Power System”
Enhancing of a DC Air-Conditioning System Based on Solar Power Generation
Published by Marwa Ben SLIMENE2,3, Mohamed Arbi KHLIFI1,3, Faculty Engineering, Islamic University of Madinah KSA (1), College of Computer Science and Engineering, University of Haʼil, Haʼil, (2), SIME Laboratory, ENSIT, University of Tunis, (3) Abstract. Photovoltaics powered DC air conditioners have a lot of potential for energy-efficient cooling while also being very cost-effective. They haveContinue reading “Enhancing of a DC Air-Conditioning System Based on Solar Power Generation”
Use of the Renewable and Waste Energy Sources in Heat Storage Systems Combined with ORC Power Plants
Published by Piotr KOLASIŃSKI, Politechnika Wrocławska, Instytut Techniki Cieplnej i Mechaniki Płynów, Zakład Termodynamik Abstract. ORC systems are mainly powered from waste and renewable energy sources. In many cases this type of energy sources are specified by the dynamic capacity and thermal characteristics. Such situation has negative influence on ORC power plant working conditions. InContinue reading “Use of the Renewable and Waste Energy Sources in Heat Storage Systems Combined with ORC Power Plants”
A Grid-Connected PV Power System Total Considers the MPPT and SSRF-SPLL Control Technologies
Published by Liu Liqun, Liu Chunxia*, Taiyuan University of Science & Technology Abstract. At present, an optimal maximum power tracking (MPPT) and grid-connected control methods for a PV power system are very important to improve the output efficiency. However, most of literatures only introduce the MPPT or PLL method, respectively. A novel MPPT method isContinue reading “A Grid-Connected PV Power System Total Considers the MPPT and SSRF-SPLL Control Technologies”
Feasibility Analyses of Hybrid Wind-PV-Battery Power System in Dongwangsha, Shanghai
Published by Liu Liqun, Liu Chunxia, Taiyuan University of Science & Technology Abstract. This paper gives the feasibility analysis of a wind-PV-battery system for an off-grid power station specially located in remote village of Dongwangsha, Shanghai. The simulation and optimization results indicated the feasibility analyses of the proposed hybrid wind-PV system with storage battery backup.Continue reading “Feasibility Analyses of Hybrid Wind-PV-Battery Power System in Dongwangsha, Shanghai”