Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP

Published by Zia Hameed1, Muhammad Rafay Khan Sial2, Adnan Yousaf3, Muhammad Usman Hashmi,Faculty of Engineering and Technology, Superior University, 17-km off Raiwind Road Lahore PakistanEmails: zia.hameed@superior.edu.pk, rafay.khan@superior.edu.pk, adnan.yousaf@superior.edu.pk Abstract—Power System Harmonics is a real point of concern for Electrical Engineers. In power systems, non-linear loads are permanently connected, unlike transients and other distortions are produced.Continue reading “Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP”

A Review of Power System Transient Stability Analysis and Assessment

Published by Huimin Wang1, and Zhaojun Li2,1School of mechanical and electrical engineering University of Electronic Science and Technology of China Chengdu, China. Email: hmwang1206@163.com2Department of Industrial Engineering and Engineering Management Western New England University, Springfield, MA, 01106. Email: zhaojun.li@wne.edu Abstract—The failure of power system transient stability is one of the main factors causing catastrophic accidentsContinue reading “A Review of Power System Transient Stability Analysis and Assessment”

An Update IEEEE Standard Complements

Published by Sivaraman P, SMIEEE, PEng (India), Senior Power Systems Engineer Chennai, Tamil Nadu, India We all know that Total Harmonic Distortion (THD) and Total Demand Distortion (TDD) are used to evaluate the presence of harmonics in the power system. The “IEEE Std 1547-2018 IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with AssociatedContinue reading “An Update IEEEE Standard Complements”

AC and DC Circuit Breakers for Overcurrent Protection

Published by Alex Roderick, EE Power – Technical Articles: AC and DC Circuit Breakers for Overcurrent Protection, March 05, 2021. This article highlights circuit breaker that is an overcurrent protection device (OCPD) designed to protect electrical devices and individuals from overcurrent conditions. A circuit breaker is an overcurrent protection device (OCPD) designed to protect electrical devicesContinue reading “AC and DC Circuit Breakers for Overcurrent Protection”

Harmonic Mitigation Using Phase-shifting Transformers and Harmonic Filters

Published by Alex Roderick, EE Power – Technical Articles: Harmonic Mitigation Using Phase-shifting Transformers and Harmonic Filters, May 21, 2021. Learn about how minimise the presence of harmonics in an electrical system with harmonic transformers and filters. Three-phase loads do not generate triplen harmonics. Therefore, harmonic problems in situations where 3-phase loads dominate are primarily fromContinue reading “Harmonic Mitigation Using Phase-shifting Transformers and Harmonic Filters”

Developing Infrastructure to Charge Electric Vehicles

Published by U.S. Department of Energy – Energy Efficiency and Renewable Energy Alternative Fuels Data Center Consumers and fleets considering electric vehicles (EVs)—which include all-electric vehicles and plug-in hybrid electric vehicles (PHEVs)—need access to charging stations. For most drivers, this starts with charging at home or at fleet facilities. Charging stations at workplaces and public destinations may help bolster market acceptanceContinue reading “Developing Infrastructure to Charge Electric Vehicles”

Insulation Failure Detection in EV Batteries

Published by Ryan Hsu, Bright Toward Industrial Co., Ltd., EE Power – Industry Article: Insulation Failure Detection in EV Batteries, May 15, 2023. One of the issues with electric vehicle batteries is insulation failure. A proven approach to detecting and correcting this failure lies in ground-fault detection. However, as higher voltages become increasingly common in electricContinue reading “Insulation Failure Detection in EV Batteries”

Making Sense of Electric Vehicle Charging Options

Published by Mike Falter, EE Power – Market Insights: Making Sense of Electric Vehicle Charging Options, September 07, 2022. When it comes to charging your electric vehicle there are several options to consider based on speed, convenience and cost. In the recent article on the Wallbox acquisition of COIL, EE Power briefly reviewed the Wallbox portfolio of EV chargingContinue reading “Making Sense of Electric Vehicle Charging Options”

Trends in Electric Vehicle Fast Charging

Published by Rakesh Kumar, EE Power – Technical Articles: Trends in Electric Vehicle Fast Charging, February 02, 2023. Ultra-fast charging methodology, ultra-fast charging station architectures, and improved battery technology are some promising trends for fast-charging electric vehicles. EVs hold the potential for decarbonizing the transportation sector. But the crucial impediment to the adoption of electrified transportationContinue reading “Trends in Electric Vehicle Fast Charging”

The Impact of EVs on the Electric Grid

Published by Harsha Korde, EE Power – News: The Impact of EVs on the Electric Grid, May 14, 2022 With gas prices rising, electric vehicles are becoming more popular, but transportation decarbonization remains a major issue. With gasoline prices rising and the effects of climate change increasingly acute, transportation electrification is gaining steam in countries throughoutContinue reading “The Impact of EVs on the Electric Grid”