Published by Alex Roderick, EE Power – Technical Articles: Electrical Shock and its Effects, August 17, 2021. Anyone working on electrical equipment should have respect for all voltages, have knowledge of the principles of electricity, and follow safe work procedures. An electrical shock occurs when a body becomes a part of an electrical circuit. The effectsContinue reading “Electrical Shock and its Effects”
Category Archives: Power Quality
Overvoltage of Atmospheric Origin
Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Overvoltage of atmospheric origin Overvoltage definitions Overvoltage (in a system) any voltage between one phase conductor and earth or between phase conductors having a peak value exceeding the corresponding peak of the highest voltage for equipment. Definition from the International Electrotechnical Vocabulary (IEV 604-03-09); available on [1] VariousContinue reading “Overvoltage of Atmospheric Origin”
Solutions to Mitigate Harmonics
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Solutions to mitigate harmonics There are three different types of solutions to attenuate harmonics: • Modifications in the installation• Special devices in the supply system• Filtering Basic solutions to mitigate harmonics To limit the propagation of harmonics in the distribution network, different solutions are availableContinue reading “Solutions to Mitigate Harmonics”
Harmonics Standards
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Harmonics standards Harmonic emissions are subject to various standards and regulations: • Compatibility standards for distribution networks• Emissions standards applying to the equipment causing harmonics• Recommendations issued by Utilities and applicable to installations In view of rapidly attenuating the effects of harmonics, a tripleContinue reading “Harmonics Standards”
Main Effects of Harmonics in Electrical Installations
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Main effects of harmonics in electrical installations Effects of harmonics – Resonance The simultaneous use of capacitive and inductive devices in distribution networks may result in parallel or series resonance. The origin of the resonance is the very high or very low impedance values atContinue reading “Main Effects of Harmonics in Electrical Installations”
Monitoring of Low Voltage Grids with the use of SAIDI Indexes
Published by Zbigniew ŁUKASIK1, Jacek KOZYRA1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1Uniwersytet Technologiczno-Humanistyczny w Radomiu, Wydział Transportu i Elektrotechniki (1) Abstract. A new method of established and justified level of operational costs for distribution network operators in a new model of regulation in force in the years 2016 – 2020 is described in this article. The changes made inContinue reading “Monitoring of Low Voltage Grids with the use of SAIDI Indexes”
Harmonic Measurement in Electrical Networks
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Harmonic measurement in electrical networks Procedures for harmonic measurement Harmonic measurements are carried out on industrial or commercial sites: • Preventively, to obtain an overall idea on distribution-network status (network mapping),• In view of corrective action, to determine the origin of a disturbance and determineContinue reading “Harmonic Measurement in Electrical Networks”
Interharmonics: What They Are, Where They Come From and What They Do
Published by Michael B. Marz, American Transmission Company, Waukesha, WI Email: mmarz@atcllc.com INTRODUCTION The use of sophisticated power electronics and communication systems to improve power system efficiency, flexibility and reliability is increasing interharmonic distortion and adding equipment sensitive to that distortion to the system. Knowledge of interharmonics, their sources, effects, measurement, limits and mitigation, willContinue reading “Interharmonics: What They Are, Where They Come From and What They Do”
Arc Flash and Overvoltage Protection
Published by Alex Roderick, EE Power – Technical Articles: Arc Flash and Overvoltage Protection, August 26, 2021. In addition to the risk of electrical shock, other hazards are present when work is performed on or near energized electrical equipment or conductors. Two serious hazards are electrical arc flashes and electrical arc blasts. An arc flash isContinue reading “Arc Flash and Overvoltage Protection”
Essential Indicators of Harmonic Distortion and Measurement Principles
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Essential indicators of harmonic distortion and measurement principles A number of indicators are used to quantify and evaluate the harmonic distortion in current and voltage waveforms, namely: • Power factor• Crest factor• Harmonic spectrum• R.m.s. value These indicators are indispensable in determining any necessaryContinue reading “Essential Indicators of Harmonic Distortion and Measurement Principles”