Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Surge protection technical supplements Lightning protection standards The IEC 62305 standard parts 1 to 4 (NF EN 62305 parts 1 to 4) reorganizes and updates the standard publications IEC 61024 (series), IEC 61312 (series) and IEC 61663 (series) on lightning protection systems. Part 1 – General principles ThisContinue reading “Surge Protection Technical Supplements”
Category Archives: Power Quality
Grounding of Wind Power Systems and Wind Power Generators
Published by Sergio Panetta, International Association of Electrical Inspectors (IAEI) Magazine, Evolving Technologies – Grounding of Wind Power Systems and Wind Power Generators, May 16, 2010 Power continuity is essential in wind power projects where a tripped overcurrent device due to ground fault can have serious economic or operational consequences. An arcing phase-to-ground fault canContinue reading “Grounding of Wind Power Systems and Wind Power Generators”
Surge Protection Application Examples
Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Surge protection Application examples SPD application example in Supermarket Solutions and schematic diagram • The surge arrester selection guide has made it possible to determine the precise value of the surge arrester at the incoming end of the installation and that of the associated disconnection circuitContinue reading “Surge Protection Application Examples”
Installation of Surge Protection Device
Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Installation of Surge Protection Device Connection of Surge Protection Device Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment. The total lengthContinue reading “Installation of Surge Protection Device”
Electrical Power Quality and Harmonic Concerns
Published by Chuck Gougler, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Fundamentals – Electrical Power Quality and Harmonic Concerns, December 29, 2015 The Problem of Harmonics Harmonics are generated by nonlinear components in electrical systems, which distort the sine wave. Increasing usage of power electronics causes a corresponding increase in voltage distortion, or harmonics.Continue reading “Electrical Power Quality and Harmonic Concerns”
Circuit Overcurrent Protection
Published by Clive Kimblin, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Safety – Circuit Overcurrent Protection, March 16, 2002 Overcurrent devices protect the circuit conductors and conductor insulation from overheating. They also limit the damage associated with overheating and faults in downstream equipment. Fuses performed this function during the first days of electrical distribution,Continue reading “Circuit Overcurrent Protection”
Design of the Electrical Installation Protection System
Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Design of the electrical installation protection system To protect an electrical installation in a building, simple rules apply for the choice of • SPD(s);• its protection system. For a power distribution system, the main characteristics used to define the lightning protection system and select a SPDContinue reading “Design of the Electrical Installation Protection System”
The Dangers of Stray Current Damage in Electrical Systems & Arc Flash Protection
Published by Jim Galloway, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Fundamentals – The Dangers of Stray Current Damage in Electrical Systems & Arc Flash Protection, July 3, 2019 The new extension to the factory is finally finished. The engineers have produced a state-of-the-art design; the qualified electricians have completed a professional installation withContinue reading “The Dangers of Stray Current Damage in Electrical Systems & Arc Flash Protection”
Principle of lightning Protection
Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Principle of lightning protection General rules of lightning protection Procedure to prevent risks of lightning strike The system for protecting a building against the effects of lightning must include: • protection of structures against direct lightning strokes;• protection of electrical installations against direct and indirect lightningContinue reading “Principle of lightning Protection”
How to Select the Right Current Transformer for Your Application
Published by Accuenergy, November 4, 2021. Help me choose the Right CT If you have a power measurement project coming up, chances are you have narrowed down your search for a power meter to a few choices. Whether it’s a multi-circuit application or a high-precision metering in an industrial setting, the next step in project preparationContinue reading “How to Select the Right Current Transformer for Your Application”