An Overview of Energy Storage Systems and Their Applications

Published by Pietro Tumino, EE Power – Technical Articles: An Overview of Energy Storage Systems and Their Applications, September 18, 2020. This article will describe the main applications of energy storage systems and the benefits of each application. The continuous growth of renewable energy sources (RES) had drastically changed the paradigm of large, centralized electric energyContinue reading “An Overview of Energy Storage Systems and Their Applications”

Understanding the Interaction between Lightning and Power Transmission Lines

Published by Lorenzo Mari, EE Power – Technical Articles: Understanding the Interaction between Lightning and Power Transmission Lines, November 21, 2020. Learn about the impact lightning strikes have on transmission lines and proper grounding’s role in lowering the chances of irreversible damage to a power system. Lightning disturbances are usually a significant issue for transmissionContinue reading “Understanding the Interaction between Lightning and Power Transmission Lines”

AC Ground Faults, the Boater, and ABYC—Understanding Equipment Leakage Circuit Interrupters (ELCIs) and Ground Fault Circuit Interrupters (GFCIs) to make your boat safer.

Published by Blue Sea Systems Inc., website: http://www.bluesea.com There are two potential failures in a boat’s electrical system that can put people on or around the boat at risk of lethal electric shock. Understanding Equipment Leakage Circuit Interrupters (ELCIs) and Ground Fault Circuit Interrupters (GFCIs) to make your boat safer. In a properly functioning marineContinue reading “AC Ground Faults, the Boater, and ABYC—Understanding Equipment Leakage Circuit Interrupters (ELCIs) and Ground Fault Circuit Interrupters (GFCIs) to make your boat safer.”

Surge Protection Technical Supplements

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Surge protection technical supplements Lightning protection standards The IEC 62305 standard parts 1 to 4 (NF EN 62305 parts 1 to 4) reorganizes and updates the standard publications IEC 61024 (series), IEC 61312 (series) and IEC 61663 (series) on lightning protection systems. Part 1 – General principles ThisContinue reading “Surge Protection Technical Supplements”

Grounding of Wind Power Systems and Wind Power Generators

Published by Sergio Panetta, International Association of Electrical Inspectors (IAEI) Magazine, Evolving Technologies – Grounding of Wind Power Systems and Wind Power Generators, May 16, 2010 Power continuity is essential in wind power projects where a tripped overcurrent device due to ground fault can have serious economic or operational consequences. An arcing phase-to-ground fault canContinue reading “Grounding of Wind Power Systems and Wind Power Generators”

Surge Protection Application Examples

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Surge protection Application examples SPD application example in Supermarket Solutions and schematic diagram • The surge arrester selection guide has made it possible to determine the precise value of the surge arrester at the incoming end of the installation and that of the associated disconnection circuitContinue reading “Surge Protection Application Examples”

Installation of Surge Protection Device

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Installation of Surge Protection Device Connection of Surge Protection Device Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment. The total lengthContinue reading “Installation of Surge Protection Device”

Electrical Power Quality and Harmonic Concerns

Published by Chuck Gougler, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Fundamentals – Electrical Power Quality and Harmonic Concerns, December 29, 2015 The Problem of Harmonics Harmonics are generated by nonlinear components in electrical systems, which distort the sine wave. Increasing usage of power electronics causes a corresponding increase in voltage distortion, or harmonics.Continue reading “Electrical Power Quality and Harmonic Concerns”

Circuit Overcurrent Protection

Published by Clive Kimblin, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Safety – Circuit Overcurrent Protection, March 16, 2002 Overcurrent devices protect the circuit conductors and conductor insulation from overheating. They also limit the damage associated with overheating and faults in downstream equipment. Fuses performed this function during the first days of electrical distribution,Continue reading “Circuit Overcurrent Protection”

Design of the Electrical Installation Protection System

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Design of the electrical installation protection system To protect an electrical installation in a building, simple rules apply for the choice of • SPD(s);• its protection system. For a power distribution system, the main characteristics used to define the lightning protection system and select a SPDContinue reading “Design of the Electrical Installation Protection System”