Analysis of Long-Time Efficiency of Photovoltaic Installation

Published by Jacek DĄBROWSKI, Ewa KRAC, Krzysztof GÓRECKI Katedra Elektroniki Morskiej, Akademia Morska w Gdyni Abstract. In the paper the results of long-time investigations of the photovoltaic installation situated in Gdynia Maritime University are presented. A short description of the considered installation and the weather station making possible continuous monitoring of weather parameters are included.Continue reading “Analysis of Long-Time Efficiency of Photovoltaic Installation”

Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements

Published by Ana Maria Blanco1, Britta Heimbach2, Bruno Wartmann2, Jan Meyer1, Marco Mangani2, Martin Oeschger2 1Institute of Electrical Power Systems and High Voltage Engineering, Technische UniversitätDresden, Dresden, Germany2Elektrizitätswerk der Stadt Zürich – EWZ, Zurich, Switzerland1E-mail: ana.blanco@tu-dresden.de 24th International Conference & Exhibition on Electricity Distribution (CIRED), 12-15 June 2017.Session 2: Power quality and electromagnetic compatibility Abstract:Continue reading “Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements”

Selected Aspects of Electrical Equipment Operation with Respect to Power Quality and EMC

Published by Paweł A. MAZUREK, Lublin University of Technology, Institute of Electrical Engineering and Electrotechnologies Abstract. The effectiveness of measures to improve the quality of electricity and the electromagnetic compatibility of electrical equipment is linked to limiting the disturbances introduced by receivers to the power grid and depends on the identification of such interference. TheContinue reading “Selected Aspects of Electrical Equipment Operation with Respect to Power Quality and EMC”

Billing Measurements in the High and Extra-High Voltage Network taking into Account the New Frequency Classes According to IEC 61869-1 ED2 (AFDIS)

Published by Roland Buerger (Senseleq B.V.), Dr. Thomas Heid (CONDIS SA) Internationally, it is not easy to specify the range of high voltage exactly. The boundary between medium and high voltage is between 30 kV and 100 kV, depending on local and historical conditions. In the current version of EN 50160 from 2020, the voltageContinue reading “Billing Measurements in the High and Extra-High Voltage Network taking into Account the New Frequency Classes According to IEC 61869-1 ED2 (AFDIS)”

Operating Assessment of Local Power Grid Development Considered Captive Power Plant and Expanding Structure

Published by Arif Nur AFANDI1,2,3, Irham FADLIKA1, Langlang GUMILAR1, Takeshi HIYAMA4 1Electrical Engineering, Universitas Negeri Malang, Malang, Indonesia 2Center for Advanced Materials for Renewable Energy, Universitas Negeri Malang, Malang, Indonesia3Smart Power and Advanced Energy Systems Research Center, Batu, Jawa Timur, Indonesia4The IROAST, Kumamoto University, Kumamoto, Japan Abstract. Based on current developments related to the applicationContinue reading “Operating Assessment of Local Power Grid Development Considered Captive Power Plant and Expanding Structure”

Industrial Harmonic Filter Design

Published by Electrotek Concepts, Inc., PQSoft Case Study: Industrial Harmonic Filter Design, Document ID: PQS0504, Date: June 30, 2005. Abstract: The industrial harmonic problem can be solved using a comprehensive approach including site surveys, harmonic measurements, and computer simulations. Simple calculations are used to determine the system resonant frequencies and then the preliminary model development isContinue reading “Industrial Harmonic Filter Design”

Assessment of the Impact of Photovoltaic System on the Power Quality in the Distribution Network

Published by Marek GAŁA, Andrzej JĄDERKO, Czestochowa University of Technology, Faculty of Electrical Engineering Abstract. The paper offers a characteristic of a photovoltaic (PV) system with the function UPS, equipped with energy storage AQUION ENERGY Battery 25 kWh and a system for monitoring and management of energy flow. Results and their analysis is presented forContinue reading “Assessment of the Impact of Photovoltaic System on the Power Quality in the Distribution Network”

Faults and Defects in Power Transformers – A Case Study

Published by Cacilda de Jesus Ribeiro1; André Pereira Marques2,3; Cláudio Henrique Bezerra Azevedo2; Denise Cascão PoliSouza1; Bernardo Pinheiro Alvarenga1; Reinaldo Gonçalves Nogueira1 1School of Electrical and Computer Engineering, Federal University of Goiás, Goiânia, GO, Brazil,2CELG Distribuição, Goiânia, GO, Brazil,3Federal Institute of Education, Science and Technology of Goiás, Goiânia, GO, Brazil Abstract – Power transformers playContinue reading “Faults and Defects in Power Transformers – A Case Study”

Cars with Electric Drive and External Costs of Road Transport

Published by Wojciech GIS1, Zdzisław KORDEL2, Maciej MENES1,Motor Transport Institute (1), The University of Gdańsk (2) Abstract. The paper describes external environmental costs of road transport. Article presents also an assessment of the so-called reduction. “Marginal costs” such as the cost of fuel emissions, noise and greenhouse gas emissions, by the introduction into service, inContinue reading “Cars with Electric Drive and External Costs of Road Transport”

Modeling of Overvoltages in Gas Insulated Substations

Published by Tomasz KUCZEK, Marek FLORKOWSKI, ABB Corporate Research Center in Krakow, Poland Abstract. Gas Insulated Substations (GIS) are broadly used for transmission and distribution of electric power. Due to the interactions with a network and various environmental phenomena like lightning the GIS are subjected to the Very Fast Transients (VFT). Such VFT can beContinue reading “Modeling of Overvoltages in Gas Insulated Substations”