Influence of Dispersed Generation on Reliability of Electric Network

Published by Juliya MALOGULKO, Svyatoslav VYSHNEVSKY , Iryna KOTYLKO, Natalia SOBCHUK, Vinnitsa National Technical University Abstract. The article analyzes the pace of increase in the generation of photovoltaic stations in the context of the combined electricity system of Ukraine and the energy supply company of PJSC “Vinnytsyaoblenergo”. An analysis of existing regulatory documents regulating theContinue reading “Influence of Dispersed Generation on Reliability of Electric Network”

Measurement of Electric Current using Optical Fibers: A Review

Published by Jan NEDOMA, Marcel FAJKUS, Radek MARTINEK, VSB – Technical university of Ostrava Abstract. This article deals with the measurement of electric current in the energy via optical fibers. Nowadays, the measurement of the electrical current by using optical fiber most commonly based on the principle of Faraday effects, thus the magneto-optic effect. FOCSContinue reading “Measurement of Electric Current using Optical Fibers: A Review”

Modeling the Transient Response of Lightning Current on Grounding Systems Wind Turbines

Published by Amina DJABOREBBI, Boubakeur ZEGNINI, Djillali MAHI, Amar TELIDJI University of Laghouat, PoBox 37 G, Mkam Laghouat 03000, Algeria. Abstract. The paper deals with transient analysis of grounding systems wind turbines. To improve the accuracy of lightning impact studies on wind power grid generation, it is necessary to develop faster, more accurate simulation toolsContinue reading “Modeling the Transient Response of Lightning Current on Grounding Systems Wind Turbines”

On Capability of Different FACTS Devices to Mitigate a Range of Power Quality Phenomena

Published by Huilian Liao, Jovica V. Milanović, School of Electrical and Electronic Engineering, The University of Manchester, Manchester M60 1QD, UK E-mail: milanovic@manchester.ac.uk. IET Generation, Transmission & Distribution – Research Article Abstract: This study investigates the impact of different flexible AC transmission system (FACTS) devices on critical power quality (PQ) phenomena including voltage sags, harmonicsContinue reading “On Capability of Different FACTS Devices to Mitigate a Range of Power Quality Phenomena”

Impacts of Fault Diagnosis Schemes on Distribution System Reliability

Published by Shahram Kazemi, Member, IEEE, Matti Lehtonen, and Mahmud Fotuhi-Firuzabad, Senior Member, IEEE.IEEE TRANSACTIONS ON SMART GRID, VOL. 3, NO. 2, JUNE 2012 Abstract—Design and development of fault diagnosis schemes (FDS) for electric power distribution systems are major steps in realizing the self-healing function of a smart distribution grid. The application of the FDSContinue reading “Impacts of Fault Diagnosis Schemes on Distribution System Reliability”

Problems of Measuring the Electrical Parameters of Geopolymer Concretes

Published by 1. Michał KOZIOŁ1, 2. Jarosław ZYGARLICKI1, 3. Dariusz ZMARZŁY1, 4. Elżbieta JANOWSKA-RENKAS2, Politechnika Opolska, Wydział Elektrotechniki, Automatyki i Informatyki (1), Politechnika Opolska, Wydział Budownictwa i Architektury (2)ORCID: 1. 0000-0001-9075-8656; 2. 0000-0001-9330-4369; 3. 0000-0001-9421-4277; 4. 0000-0002-1877-6216 Abstract. The article presents the problems of measuring electrical parameters on the example of determining the resistivity ofContinue reading “Problems of Measuring the Electrical Parameters of Geopolymer Concretes”

Practical Experiences and Mitigation Methods of Harmonics in Wind Power Plants

Published by Babak Badrzadeh, Senior Member, IEEE, and Manoj Gupta IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 49, NO. 5, SEPTEMBER/OCTOBER 2013 Abstract—This paper discusses practical experiences and mitigation methods of harmonics in wind power plants. Traces obtained from harmonic measurements of actual wind turbines are presented for the type 3 and type 4 turbines, andContinue reading “Practical Experiences and Mitigation Methods of Harmonics in Wind Power Plants”

Intelligent Redundant Measuring Circuit with Primary Circuit Error Detection

Published by Bartosz DOMINIKOWSKI, Politechnika Łódzka, Instytut Systemów Inżynierii Elektrycznej. ORCID: 1. 0000-0002-4762-2005 Abstract. Differential amplifiers in measuring systems are often exposed to external factors, which may lead to disturbance of their proper operation. Due to the capabilities of microprocessor systems, the intelligent algorithms work well in systems for diagnosing circuit errors such as aContinue reading “Intelligent Redundant Measuring Circuit with Primary Circuit Error Detection”

Analysis of Interactions in the Circuit of the Power System with Nonlinear Load and LC Passive Filter

Published by Mirosław WCIŚLIK, Paweł STRZĄBAŁA,Kielce University of Technology, Department of Electric Engineering, Automatic Control and Computer Science Abstract. The paper deals with an AC circuit containing the nonlinear load and a LC passive filter. Nonlinear load voltage at the power terminals proportional to the signum function of current is considered. The current-voltage characteristic ofContinue reading “Analysis of Interactions in the Circuit of the Power System with Nonlinear Load and LC Passive Filter”

Analysis of Selected Power Quality Indicators at Non-Measured Distribution Network Points Based on Measurements at Other Points

Published by Andrzej FIRLIT, Bogusław ŚWIĄTEK, Zbigniew HANZELKA, Krzysztof PIĄTEK, Mateusz DUTKA, Tomasz SIOSTRZONEK, AGH University of Science and Technology, Krakow, Poland Abstract. The article presents a method enabling estimation of the selected power quality indicators at a given point of a power network, on the basis of the power quality indicators recorded at theContinue reading “Analysis of Selected Power Quality Indicators at Non-Measured Distribution Network Points Based on Measurements at Other Points”