January 2021 The EPRI Power Quality Knowledge Development and Transfer supplemental project provides a wealth of high-impact resources in a well-designed, readable, and accessible format. Paramount among these are numerous and highly readable documents covering a wide range of PQ topics, written not only for use by busy PQ professionals, but also to expedite problemContinue reading “EPRI PQ Knowledge Development and Transfer 2020 Year-End Update”
Author Archives: PQBlog
How to Conduct an Energy Audit Using the Energy Platform EP1
White Paper Introduction Sophisticated energy analyzers introduced in the 80s were able to trend and record energy usage and help identify when, where, and how much electrical energy was being used. However, due to limited user-interface capabilities, these analyzers printed to paper tape and tended to be complex to operate. At that time, the costContinue reading “How to Conduct an Energy Audit Using the Energy Platform EP1”
An Investigation on the Validity of Power-Direction Method for Harmonic Source Determination
Published by Wilsun Xu and Xian Liu, Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada Yilu Liu, Department of Electrical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA Published in IEEE Transaction on Power Delivery, Vol. 18, No. 1, January 2003 Abstract The power-direction method has been used widelyContinue reading “An Investigation on the Validity of Power-Direction Method for Harmonic Source Determination”
Interaction between Grid-Connected PV systems & LED Lamps: Directions for Further Research on Harmonics and Supraharmonics
Published by Tatiano Busatto, Fahim Abid, Anders Larsson and Math H. J. Bollen, Electric Power Engineering, Luleå University of Technology, Skellefteå 931 87, Sweden Email: tatiano.busatto@ltu.se Gaurav Singh, Department of Electrical and Computer Engineering, Clemson University, Clemson, South Carolina 29634, USA Continue reading “Interaction between Grid-Connected PV systems & LED Lamps: Directions for Further Research on Harmonics and Supraharmonics”
The Importance of Good Power Quality
Published by Dr. Kurt Schipman & Dr. François Delincé , ABB Power Quality Products, Belgium ABSTRACT This paper explains the problems that are due to poor Power Quality in electrical systems and shows their possible financial consequences. Power Quality is characterized by parameters that express harmonic pollution, reactive power, and load unbalance. The best possibleContinue reading “The Importance of Good Power Quality”
Smart Capacitor
Published by Wendy Wang, Jiangsu Modern Electric Technology Co., Ltd. The first developer of smart capacitor in China; Nantong, Jiangsu, China. Introduction Smart capacitor integrates such advanced technologies as modern measure-control, power electronics, network communication, automation control, power capacitor and others. It changes the outdated controller technology of traditional reactive power compensation device and theContinue reading “Smart Capacitor”
Voltage Disturbances Flicker Measurement
Published by Zbigniew Hanzelka & Andrzej Bie´n, AGH University of Science and Technology, October 2005 Flicker Measurement Introduction The power supply network voltage varies over time due to perturbations that occur in the processes of electricity generation, transmission, and distribution. Interaction of electrical loads with the network causes further deterioration of the electrical power quality.Continue reading “Voltage Disturbances Flicker Measurement”
Direction of Harmonics & Flicker
Published by Arbiter Systems, Inc. Enabling Tomorrow’s Technology Today Overview As regulatory authorities impose ever-stricter requirements for power quality, utilities increasingly want to know which customer is imposing harmonics and flicker on the utilities power system. As a result, we are often asked if we can determine the “direction” of harmonic power flow, and whatContinue reading “Direction of Harmonics & Flicker”
References for SARFI PQ Index
Published by Terry Chandler, Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. E-mail: terryc@powerquality.org, terryc@powerquality.co.th FYI, PQView calculates these automatically from the PQView database of all instruments. For more information on PQView, you can visit the blog post PQView & PQView DE System Average RMS (Variation) Frequency represents the average number of specified rms variation measurementContinue reading “References for SARFI PQ Index”
Need of Voltage Quality Regulation in the Future
Published by S.Bhattacharyya, Dr. J.M.A.Myrzik, J.F.G.Cobben, and Prof. W.L.Kling, Electrical Power Systems Group Technical University Eindhoven Eindhoven, the Netherlands E-mail: s.bhattacharyya@tue.nl M.van Lumig and Dr. M.Didden Business Development Team Laborelec NL Beek-Maastricht Airport, the Netherlands Published in 9th International Conference on Electrical Power Quality and Utilisation Date: 9-11 Oct. 2007, Barcelona, Spain Abstract Electricity as aContinue reading “Need of Voltage Quality Regulation in the Future”