Inrush Current Impact Limitation in Smart Building Applications

Published by 1. Mariusz STOSUR1, 2. Kacper SOWA2, 3. Piotr ORAMUS1, 4. Adam RUSZCZYK2, 5. Pawel ALOSZKO3,ABB E-mobility, Krakow, Poland (1), ABB Technology Center, Krakow, Poland (2), ABB Corporate Technology Center, Krakow, Poland (3)ORCID. 1. 0000-0002-1522-3405, 2. 0000-0001-8246-2337, 3. 0000-0002-4810-3936, 4. 0000-0001-7477-8139, 5. 0000-0002-1668-6292 Abstract: This paper presents a hybrid switches based on semiconductors andContinue reading “Inrush Current Impact Limitation in Smart Building Applications”

Medium Voltage Switching Transient Induced Potential Transformer Failures; Prediction, Measurement and Practical Solutions

Published by Daniel McDermit1, David D. Shipp2, Thomas J. Dionise3, Visuth Lorch4,1Sr. Project Manager Turner Construction Company Chicago, IL2PE Eaton Electrical Group Power Systems Engineering Warrendale, PA Fellow, IEEE3PE Eaton Electrical Group Power Systems Engineering Warrendale, PA Senior Member, IEEE4Eaton Electrical Group Power Systems Engineering Warrendale, PA Abstract— During commissioning of a large data center,Continue reading “Medium Voltage Switching Transient Induced Potential Transformer Failures; Prediction, Measurement and Practical Solutions”

Measures and Technical Means for Increasing Efficiency and Reliability of Extra High Voltage Transmission Lines

Published by Vladislav KUCHANSKYY1, Paul SATYAM2, Olena RUBANENKO3, Iryna HUNKO4,Institute of Electrodynamics of NAS of Ukraine (1), Kiev, Ukraine University of the West of England (2), Bristol United Kingdom, Regional Innovational Center at the Faculty of Electrical Engineering University of West Bohemia (3), Plzen, Czech Republic, Vinnytsia National Technical University (4), Vinnytsia, Ukraine Abstract. ElectromagneticContinue reading “Measures and Technical Means for Increasing Efficiency and Reliability of Extra High Voltage Transmission Lines”

Power Quality — Basics Commercial Buildings

Published by HSB, Power quality — basics Commercial property, One State Street P.O. Box 5024 Hartford, CT 06102-5024 Tel: (800) 472-1866. Website: HSB.com Introduction Power quality is a general term used to describe the compatibility between connected equipment and its electrical supply. The supply system can be affected by changes to the frequency or amplitudeContinue reading “Power Quality — Basics Commercial Buildings”

Autotransformers for Power Systems

Published by Waldemar ZIOMEK, PTI Manitoba Inc., Winnipeg, MB, Canada Abstract. When the primary and secondary voltages are obtained from the same winding, or from two windings which are galvanically connected, such a transformer is called an autotransformer. The paper will focus on fundamentals, design and applications of autotransformers of core-type design. The selected problemsContinue reading “Autotransformers for Power Systems”

Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents

Published by Rafael ALIPIO, Renan SEGANTINI, Federal Centre of Technological Education of Minas Gerais Abstract. This paper assesses the transient distribution of potentials along a grounding grid subjected to currents representative of first and subsequent strokes. It is shown that the transient non-uniform distribution of potential along the grounding system may lead to the flowContinue reading “Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents”

Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP

Published by Zia Hameed1, Muhammad Rafay Khan Sial2, Adnan Yousaf3, Muhammad Usman Hashmi,Faculty of Engineering and Technology, Superior University, 17-km off Raiwind Road Lahore PakistanEmails: zia.hameed@superior.edu.pk, rafay.khan@superior.edu.pk, adnan.yousaf@superior.edu.pk Abstract—Power System Harmonics is a real point of concern for Electrical Engineers. In power systems, non-linear loads are permanently connected, unlike transients and other distortions are produced.Continue reading “Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP”

A Review of Power System Transient Stability Analysis and Assessment

Published by Huimin Wang1, and Zhaojun Li2,1School of mechanical and electrical engineering University of Electronic Science and Technology of China Chengdu, China. Email: hmwang1206@163.com2Department of Industrial Engineering and Engineering Management Western New England University, Springfield, MA, 01106. Email: zhaojun.li@wne.edu Abstract—The failure of power system transient stability is one of the main factors causing catastrophic accidentsContinue reading “A Review of Power System Transient Stability Analysis and Assessment”

Understanding the Interaction between Lightning and Power Transmission Lines

Published by Lorenzo Mari, EE Power – Technical Articles: Understanding the Interaction between Lightning and Power Transmission Lines, November 21, 2020. Learn about the impact lightning strikes have on transmission lines and proper grounding’s role in lowering the chances of irreversible damage to a power system. Lightning disturbances are usually a significant issue for transmissionContinue reading “Understanding the Interaction between Lightning and Power Transmission Lines”

Substation Protection Against Transient Overvoltages and Lightning Strikes

Published by Lorenzo Mari, EE Power – Technical Articles: Substation Protection Against Transient Overvoltages and Lightning Strikes, December 11, 2020. Learn how surge arresters protect power substations against lightning and switching overvoltages. Transient overvoltages are typical of power systems. The sources of overvoltages are direct or nearby lightning strikes, switching operations, electromagnetic pulses, and electrostatic discharges.Continue reading “Substation Protection Against Transient Overvoltages and Lightning Strikes”