Effect of Solar Radiation on Power Losses and Capacity of Insulated and Non-Insulated Wires of Overhead Power Lines

Published by Stanilav S. Girshin1, Igor A. Sorokin2, Aleksandr N. Smerdin3, Aleksandr AY. Bigun1, Elena V. Petrova1, Vladislav M. Trotsenko1, Vladimir N. Goryunov1, George S. Smorodin1, Omsk State Technical Univercity, Omsk, Russia (1)Public Join Stock «Interregional Distribution Grid Company of Siberia» (2)Omsk State Transport University, Omsk, Russian (3) Abstract. The influence of solar radiation onContinue reading “Effect of Solar Radiation on Power Losses and Capacity of Insulated and Non-Insulated Wires of Overhead Power Lines”

Distributed Photovoltaic Integration as Complementary Energy: Consideration of Solutions for Power Loss and Load Demand Growth Problems

Published by Salama MANJANG1, Yuli Asmi RAHMAN2,University of Hasanuddin (1), University of Tadulako (2), Indonesia Abstract. The purpose of this study is to optimize the location and capacity of PV in the feeder distribution system 20 kV of Central Sulawesi, Indonesia. The proposed method uses the optimization method of development from the genetic algorithm, namelyContinue reading “Distributed Photovoltaic Integration as Complementary Energy: Consideration of Solutions for Power Loss and Load Demand Growth Problems”

Methods of Calculating Solar Insolation for the Assessment of Energy Efficiency of Solar Power Plants

Published by Sergey CHIZHMA, Artyom ZAKHAROV, Immanuel Kant Baltic Federal University (Kaliningrad, Russia) Abstract. The authors explore a number of methods of calculating insolation on a tilted arbitrarily oriented surface and choose the most efficient one for conducting the performance and efficiency analysis of solar power plants. The validity of the method is tested usingContinue reading “Methods of Calculating Solar Insolation for the Assessment of Energy Efficiency of Solar Power Plants”

Efficient Off Grid Solar Powered DC Air Conditioning System

Published by Mohamed Arbi KHLIFI1, Marwa Ben Slimene2,Department of Electrical Engineering, Faculty Engineering, Islamic University of Madinah, Madinah Monawarah, (1)Department of Computer Science and Engineering, College of Computer Science and Engineering, University of Haʼil, Haʼil, (2) Abstract. Almost all residential air conditioners in KSA are inverter air conditioners in which a AC motor is drivenContinue reading “Efficient Off Grid Solar Powered DC Air Conditioning System”

Particle Swarm Optimization Algorithm for Solar PV System under Partial Shading

Published by Fawaz S. Abdulla1, Ali N. Hamoodi2, Abdulaziz M. Kheder3, Northern Technical University, Engineering Technical College of Mosul, Mosul, Iraq. ORCID. 1. 0000-0002-6888-0580, 2. /000-0003-0991-3538, 3. 0000-0003-2606-4697 Abstract. Conventional maximum power point tracking (MPPT) has several demits such as steady-state oscillation and the inability to distinguish between multipacks generated under partial shading conditions (PSC).Continue reading “Particle Swarm Optimization Algorithm for Solar PV System under Partial Shading”

Solar Energy and LED Technologies for Street Lighting Demand Side Management SLDSM

Published by Aziz HAFFAF*1, Fatiha LAKDJA1,2, Rachid MEZIANE1, Djaffar OULD ABDESLAM3Electro-Technical Engineering Laboratory, Faculty of Technology, Saida University, Algeria (1) Sidi-Bel-Abbes University, Algeria (2) IRIMAS laboratory, Haute Alsace University, Mulhouse, France (3) Abstract. In this research paper, solar energy and LED technologies as a street lighting demand side management SLDSM option are carried out. TheContinue reading “Solar Energy and LED Technologies for Street Lighting Demand Side Management SLDSM”

Causes and Solutions of the Potential Induced Degradation (PID) Effect in PV Modules

Published by Pietro Tumino, EE Power – Technical Articles: Causes and Solutions of the Potential Induced Degradation (PID) Effect in PV Modules, July 09, 2020. In case you are dealing with unexpected and unreasonable power loss in your photovoltaic plant, you may be experiencing the PID effect in the PV modules.  Potential induced degradation (PID)Continue reading “Causes and Solutions of the Potential Induced Degradation (PID) Effect in PV Modules”

A Review of Electricity and Renewable Energy Sectors Status and Prospect in Jordan

Published by Mohammad Abu Sarhan, Andrzej Bien´, Szymon Barczentewicz, Rana Hassan, AGH University of Science and Technology Abstract. In Jordan, there are many extensive challenges that the country faces against the national economy growth. This is mainly because Jordan has limited primary energy resources and imports more than 90% of natural gas and crude oilContinue reading “A Review of Electricity and Renewable Energy Sectors Status and Prospect in Jordan”

Solar-Wind Hybrid Power System Analysis Using Homer for Duhok, Iraq

Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, University of Mosul (1), Ninevah University(2) Iraq. ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245 Abstract. The government of Iraq recently joined the Paris Climate Agreement, it has now begun to encourage the participation of small and large consumers to generate electricity from renewable energy resources. This article analyses aContinue reading “Solar-Wind Hybrid Power System Analysis Using Homer for Duhok, Iraq”

Solar Power Plant with Distributed System of PV Panels

Published by Mariusz ŚWIDERSKI, Michał GWÓŹDŹ, Poznan University of Technolog Abstract. In the work the other approach to a photovoltaic system is presented. With regard to an improvement of reliability of a solar system, maintaining and improving system’s efficiency, authors proposed conception of the distributed PV system. This system consists of a set of individualContinue reading “Solar Power Plant with Distributed System of PV Panels”