Published by Petr ZÁVADA1, Karel SOKANSKÝ1, VSB – Technical University of Ostrava (1) Abstract. Today, the development of power generation from renewable sources is an effort to maximize the share of total energy consumption. Big source of energy in solar and wind power plants are mostly connected to the distribution network and supply the energyContinue reading “Diagram of Daily Consumption of Electricity, Houses Appliances, Distribution them into Categories by Importance of Electricity Supply”
Tag Archives: Renewable Energy
Renewable Energy Sources Intrusion into Smart Grids – Selected Problems
Published by Bożena E. MATUSIAK, Jerzy S. ZIELIŃSKI, University of Lodz Abstract. The aim of the paper are selected problems resulting from Renewable Energy Sources (RES) intrusion into Smart Grids (SG) presentation. Upon considerations there are: wind turbines influence on power system operation, RES and microgrids operation with a Power System, new Energy Market forContinue reading “Renewable Energy Sources Intrusion into Smart Grids – Selected Problems”
Techno-Economic Analysis of Off-Grid Renewable Energy Power Station: A Case Study
Published by Liu Liqun, Liu Chunxia, Taiyuan University of Science & Technology Abstract. This paper gives the techno-economic analysis of a wind-PV-diesel system with storage battery backup for an off-grid power station specially located in Dongwangsha, studying data from a particular site in littoral China. The simulation and optimization results indicated the most optimized sizingContinue reading “Techno-Economic Analysis of Off-Grid Renewable Energy Power Station: A Case Study”
Hybrid Power System of Public Lighting in Smaller Villages
Published by Stanislav MIŠÁK, Jaroslav ŠNOBL, František DOSTÁL, Daniel DIVIŠ, VSB – Technical University of Ostrava Abstract. This article deals with the possibility of public lighting power from renewable resources, it means of a hybrid system consisting of solar panels and wind power. The factual data for dimensioning the system was obtainedby extensive exploration ofContinue reading “Hybrid Power System of Public Lighting in Smaller Villages”
Electrical Energy Storage Systems
Published by Zdeněk HRADÍLEK, Petr MOLDŘÍK, Roman CHVÁLEK VŠB – Technical University of Ostrava, Department of Electrical Power Engineering Abstract. Attention is paid to the electrical energy storage systems that are already used in the framework of electrical power system, and further to the systems that are studied and developed for this purpose. The describedContinue reading “Electrical Energy Storage Systems”
A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications
Published by Yang HAN1, Lin XU2University of Electronic Science and Technology of China (1), Shanghai Jiao Tong University (2) Abstract. This paper presents the survey of the smart grid technologies, including the background, motivation and practical applications. The driving forces for the smart grid technologies are presented, including the blackout, global energy crisis and environmentalContinue reading “A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications”
Power Quality Measurements and Analysis for Wind Turbines
Published by Mariano Sanz, Member, IEEE, Andrés Llombart, Member, IEEE, Ángel Antonio Bayod and Joaquín Mur, Student Member, IEEE Abstract— A new system for studying power quality (PQ) in wind turbines (WT) has been designed using a data acquisition board (DAQ), LabVIEW programming software and a portable PC. The system has been installed at windContinue reading “Power Quality Measurements and Analysis for Wind Turbines”
Power Quality Issues in Solar Converters: A Review
Published by J. R. Maglin & R. Ramesh, Department of Electrical and Electronics Engineering, Anna University, Chennai-25, India, E-mail: rramesh@annauniv.edu, Tel: +91-9444217600Published in European Journal of Scientific ResearchISSN 1450-216X Vol.61 No.2 (2011), pp. 321-327http://www.eurojournals.com/ejsr.htm Abstract The main objective of this paper is to identify the problems associated with solar converters in the solar power systemContinue reading “Power Quality Issues in Solar Converters: A Review”
Visualizing the Power Consumption of Bitcoin Mining
Published by Marcus Lu, Visual Capitalist, Energy Archive, April 20, 2021Website: visualcapitalist.com Visualizing the Power Consumption of Bitcoin Mining Cryptocurrencies have been some of the most talked-about assets in recent months, with bitcoin and ether prices reaching record highs. These gains were driven by a flurry of announcements, including increased adoption by businesses and institutions.Continue reading “Visualizing the Power Consumption of Bitcoin Mining”
Review of Positive and Negative Impacts of Electric Vehicles Charging on Electric Power Systems
Published by Morsy Nour 1,2,*, José Pablo Chaves-Ávila 1 , Gaber Magdy 2 and Álvaro Sánchez-Miralles1 1Institute for Research in Technology (IIT), ICAI School of Engineering, Comillas Pontifical University,28015 Madrid, Spain; jose.chaves@iit.comillas.edu (J.P.C.-Á.); alvaro.sanchez@iit.comillas.edu (Á.S.-M.)2Department of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan 81528, Egypt; gabermagdy@aswu.edu.eg, *Correspondence: morsy.mohammed@iit.comillas.edu Abstract: There is a continuousContinue reading “Review of Positive and Negative Impacts of Electric Vehicles Charging on Electric Power Systems”