Published by A. El Mofty K. Youssef, Alexandria Electricity Company , Alexandria – Egypt SUMMARY Power quality has become an increasing concern to Alexandria Electricity Company (AEC) for the last few years. Problems involving the quality of voltage to the customers are always an important point. The increased concern of power quality has resulted inContinue reading “Industrial Power Quality Problems”
Tag Archives: Power Standards
EMC for 2 to 150 kHz: A Proposal for Emission and Immunity of Equipment including Power-Line Communication
Published by Anders Larsson and Math Bollen, ELFORSK, Elforsk rapport 09:29, October 2008 Summary The frequency range from 2 to 150 kHz is not sufficiently covered in international standards. The contrast with the frequency range below 2 kHz is striking. There have traditionally been good reasons to emphasize on the lower frequency range, where theContinue reading “EMC for 2 to 150 kHz: A Proposal for Emission and Immunity of Equipment including Power-Line Communication”
Where to Go For Help
Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 5 – Where to Go For Help. Web Resources IEEE Standards Information Home of the IEEE standards; in particular 446; 519; 1100 (“The Emerald Book”, considered the key IEEE reference on power quality); 1159; 1250 and 1346. Copper.org A site by theContinue reading “Where to Go For Help”
Power Quality Standards
Published by Pacific Gas and Electric Company (PG&E) IEEE Standard 141-1993, Recommended Practice for Electric Power Distribution for Industrial Plants, aka the Red Book. A thorough analysis of basic electrical-system considerations is presented. Guidance is provided in design, construction, and continuity of an overall system to achieve safety of life and preservation of property; reliability; simplicityContinue reading “Power Quality Standards”
Power Quality Standards: CBEMA, ITIC, SEMI F47, IEC 61000-4-11/34
Published by Mark Stephens, PE, Manager, Industrial Studies, Electric Power Research Institute (EPRI), 942 Corridor Park Blvd, Knoxville, Tennessee 37932, Phone 865.218.8022, Email: mstephens@epri.com
Historical Perspective of Utility PQ Standards Year 2000 timeframe
Published by Terry Chandler, Director of Engineering, Power Quality Thailand Ltd. & Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th
Dranetz HDPQ Plus & SP Products and IEEE 519-2014
Published by Dranetz Technologies, Inc., Application Note Introduction IEEE Std. 519-2014, IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems is the most current recommended practice from the IEEE related to harmonics measurement and compliance. Although the recommended practices from the IEEE are usually only followed in North America, IEEE 519-2014 is usedContinue reading “Dranetz HDPQ Plus & SP Products and IEEE 519-2014”
Voltage Flicker Calculation Methodology
Published by Trishia Swayne, P.E., Leidos.
Understanding Power Quality Standards
Published by Dr.Ir.Mohamed Fuad Faisal, Asset Management Department, Distribution Division TNB
What is Short Circuit Analysis, and Why is it Done?
Published by Carelabs (Carelabz), Website: carelabz.com A Short circuit analysis is used to determine the magnitude of short circuit current, the system is capable of producing, and compares that magnitude with the interrupting rating of the overcurrent protective devices (OCPD). Since the interrupting ratings are based by the standards, the methods used in conducting a short circuitContinue reading “What is Short Circuit Analysis, and Why is it Done?”