Determination of Electrical and Efficiency Parameters of Air Cooling of Low-Temperature PEM Fuel Cell Stack with Power of 5kW

Published by Andrzej RAŹNIAK1, Magdalena DUDEK1, Tomasz SIWEK1, Piotr DUDEK2, Wojciech KALAWA1, AGH – Akademia Górniczo – Hutnicza im. Stanisława Staszica w Krakowie, Wydział Energetyki i Paliw (1) AGH – Akademia Górniczo – Hutnicza im. Stanisława Staszica w Krakowie, Wydział Inżynierii Mechanicznej i Robotyki (2) Abstract: The possibilities of using low-temperature hydrogen-oxygen fuel cells withContinue reading “Determination of Electrical and Efficiency Parameters of Air Cooling of Low-Temperature PEM Fuel Cell Stack with Power of 5kW”

Analysis of Changes in Electrical Parameters of Photovoltaic Roof Tiles Depending on the Place of Shading and Connection Configuration

Published by Dariusz KURZ1, Ryszard NAWROWSKI2, Szczepan KAŁUŻA3, Politechnika Poznańska, Instytut Elektrotechniki i Elektroniki Przemysłowej (1)ORCID: 1. 0000-0002-6737-0052; 2.0000-0003-0974-2935 Abstract. The paper presents the research on the influence of the connection configuration and the location of the PV cells shading on the output parameters of photovoltaic roof tiles. The problem of shading occurs in allContinue reading “Analysis of Changes in Electrical Parameters of Photovoltaic Roof Tiles Depending on the Place of Shading and Connection Configuration”

Transformer Losses and Efficiency

Published by Alex Roderick, EE Power – Technical Articles: Transformer Losses and Efficiency, June 16, 2021 In this article we will learn about the four main types of transformer losses and calculations for finding the efficiency of a transformer. Transformers, like all devices, are not perfect. While ideal transformers do not have losses, real transformers haveContinue reading “Transformer Losses and Efficiency”

Nuclear Power Plants Application in Poland – A Way to Meet the Requirements of the Paris Agreement

Published by Iva PAVLOVA-MARCINIAK, Czestochowa University of Technology, Institute of Power Engineering Abstract. The paper presents the analysis of modern nuclear energy development possibilities in Poland, which is considered as an ecological energy source. As the demand for electrical energy is constantly growing the use of such energy sources in one of the ways toContinue reading “Nuclear Power Plants Application in Poland – A Way to Meet the Requirements of the Paris Agreement”

A Home Energy Management Algorithm in Demand Response Events for Household Peak Load Reduction

Published by Maytham S. AHMED1,2 Azah MOHAMED1 , Raad Z. HOMOD3 , and Hussain SHAREEF4, Dept. of Electrical, Electronic & System Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (1)General Directorate of Electrical Energy Production- Basrah, Ministry of electricity, Iraq (2)Dept. of Oil and Gas Engineering, Basrah University for Oil and Gas, 61004Continue reading “A Home Energy Management Algorithm in Demand Response Events for Household Peak Load Reduction”

An Experimental Study of Wind Data of a Wind Farm in Kosovo

Published by Sabrije OSMANAJ1, Bukurie HOXHA2, Rexhep SELIMAJ2*1Faculty of Electrical and Computer Engineering, , 2Faculty of Mechanical Engineering, University of Pristina, Republic of Kosovo Abstract. In Kosovo, 97% of energy is generated from lignite-fired power plants. Apart from the energy generation, the combustion process emits around 8000 ktCO2/yr and 1.5 Mt of ash in theContinue reading “An Experimental Study of Wind Data of a Wind Farm in Kosovo”